Expert Recommended AccessoriesSelected by Bob, our Expert
Required Accessories9
These accessories are required to properly setup/install this product.
Optional Accessories10
Features
A Goodman high efficiency heat pump and furnace package is the perfect way to upgrade your home's HVAC system. This kit contains a GSZ heat pump with an advanced coil design to maximize efficiency. The heat pump is paired with a GCVC furnace equipped with an ECM variable speed motor. This pair was specifically chosen to provide efficient comfort year round. A cased coil and valve kit are included, making this kit an affordable, efficient, whole home solution.
Advanced Coil Design
The condenser coil of this heat pump is designed with aluminum fins and rifled copper tubing to maximize efficiency. The fins and rifling serve to increase surface area, allowing the heat transfer capabilities of the materials to shine.
SmartShift
Goodman's SmartShift technology, combined with ambient and coil temperature sensors, gives this unit a quiet and effective defrost system. SmartShift also helps to prevent short-cycling, increasing the efficiency of defrost operations.
High-Efficiency Compressor
This unit utilizes a high-efficiency scroll compressor to provide refrigerant flow. Scroll compressors are renowned for operating more smoothly and reliably than traditional compressors.
All-Aluminum Coil
Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort.
Condensate Management
The CAPF features foil-faced insulation to inhibit the formation of condensate and a rust-resistant thermoplastic drain pan to capture what does form, keeping your system safe and operational.
Advanced Heat Exchanger Design
The GCVC furnace employs a dual-diameter tubular heat exchanger design. Aluminized steel is used in construction for efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance dependability and longevity.
Secondary Heat Exchanger
This furnace produces additional heat without using more fuel by directing combustion gases through a secondary heat exchanger before they are vented. To prevent damage, this secondary heat exchanger is made of corrosion-resistant stainless steel.
Variable Speed ECM Motor
The GCVC line features a variable speed ECM motor. Variable speed motors allow the furnace to operate at higher efficiencies than multi-speed blowers by controlling the speed of the blower based on heating demands.
Extended Warranty
Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab. NOTE: Model GCVC960403BN has been temporarily suspended from production.NOTE: Due to DOE regulations, as of January 1st this unit can no longer be installed in the southwest and southeast DOE regions.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor Speed
ECM Variable-Speed
Coil Width
17.5 Inches
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide (Except CA)
Installation Available
Yes
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.0 Tons
Cooling Capacity
34600 BTU
Nominal Cooling Capacity
36000 BTU
Heating BTU
40000
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
11.5
HSPF HSPFHSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor Speed
ECM Variable-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Heating BTU
40000
High Fire Input
40000 BTU
High Fire Output
38400 BTU
Low Fire Input
28000 BTU
Low Fire Output
26880 BTU
Maximum Air Flow
1200 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
7.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
116 Pounds
Shipping Weight
116 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368837
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Compressor StagesStages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.0 Tons
Cooling BTU
36000
Cooling Capacity
36000 BTU
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
74 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
20 Amps
Recommended Breaker Size
35 Amps
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
36 1/4 Inches
Product Width
29 Inches
Product Depth
29 Inches
Product Weight
183 Pounds
Shipping Weight
199 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.5 - 3.0 Tons
Cooling BTU
36000
Nominal Minimum Cooling Capacity
30000 BTU
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
17 1/2 Inches
Product Height
30 Inches
Product Width
17 1/2 Inches
Product Depth
21 Inches
Product Weight
53 Pounds
Shipping Weight
63 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information