Welcome:  Sign In | Contact Us
Call Us: (866)-437-7998

Reznor RP-400 Gas Fired Duct Furnace - Power Vented - NG - 409 Stainless Steel Heat Exchanger - 400,000 BTU

Reznor RP-400 Gas Fired Duct Furnace - Power Vented - NG - 409 Stainless Steel Heat Exchanger - 400,000 BTU
Our Price
Compare Prices
Shipping Info
Model: RP-400-AC2
$6,187.50
Factory-Direct
Ships in 3-4 Weeks
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping
Free Lift Gate Service - 
Input Capacity (BTU/h)
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Heat Exchanger Material
Add-Ons
 
Factory-Direct
Ships in 3-4 Weeks
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Reznor RP-400-AC2 Gas Fired Duct Furnace is an outdoor gas fired duct furnace which provides a heating output capacity of 320000 with an 80% thermal efficiency. This RP model has a high fire input of 400000. RP model furnaces are the heating component of heating or heating/cooling systems and require a separate blower system for air delivery. RP-400-AC2 is approved for a 50-90 F temperature rise range and includes power vent system. Units include a blocked vent shut-off system.
  • Reznor RP-400-AC2 Features
  • Stainless steel heat exchanger
  • Aluminized steel burners with stainless steel insert
  • 24 volt control voltage transformer
  • High limit safety cutout
  • Redundant single stage combination gas valve
  • Spark-ignited intermittent safety pilot
  • Power venter
Specifications
General Information
Product Line
RP
Heat Exchanger Material
Stainless Steel
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
Stages
Single Stage
Speed Settings
Multi-Speed
Performance
Heating Capacity
320000 BTU
High Fire Input
400,000 BTU
Efficiency
80 %
Minimum Air Flow
3275 CFM
Maximum Air Flow
5895 CFM
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Gas Connection Size
0.75 Inches
Product Height
38.53125 Inches
Product Width
61.1875 Inches
Product Depth
26 Inches
Product Weight
361 Pounds
Certifications
Country of Origin
United States
CSA Listed
Yes
ANSI Certified
Yes
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Features
Features
    Reznor RP-400-AC2 Gas Fired Duct Furnace is an outdoor gas fired duct furnace which provides a heating output capacity of 320000 with an 80% thermal efficiency. This RP model has a high fire input of 400000. RP model furnaces are the heating component of heating or heating/cooling systems and require a separate blower system for air delivery. RP-400-AC2 is approved for a 50-90 F temperature rise range and includes power vent system. Units include a blocked vent shut-off system.
  • Reznor RP-400-AC2 Features
  • Stainless steel heat exchanger
  • Aluminized steel burners with stainless steel insert
  • 24 volt control voltage transformer
  • High limit safety cutout
  • Redundant single stage combination gas valve
  • Spark-ignited intermittent safety pilot
  • Power venter
Specifications
General Information
Product Line
RP
Heat Exchanger Material
Stainless Steel
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
Stages
Single Stage
Speed Settings
Multi-Speed
Performance
Heating Capacity
320000 BTU
High Fire Input
400,000 BTU
Efficiency
80 %
Minimum Air Flow
3275 CFM
Maximum Air Flow
5895 CFM
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Gas Connection Size
0.75 Inches
Product Height
38.53125 Inches
Product Width
61.1875 Inches
Product Depth
26 Inches
Product Weight
361 Pounds
Certifications
Country of Origin
United States
CSA Listed
Yes
ANSI Certified
Yes
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Product Specs
+
Specifications
General Information
Product Line
RP
Heat Exchanger Material
Stainless Steel
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
Stages
Single Stage
Speed Settings
Multi-Speed
Performance
Heating Capacity
320000 BTU
High Fire Input
400,000 BTU
Efficiency
80 %
Minimum Air Flow
3275 CFM
Maximum Air Flow
5895 CFM
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Gas Connection Size
0.75 Inches
Product Height
38.53125 Inches
Product Width
61.1875 Inches
Product Depth
26 Inches
Product Weight
361 Pounds
Certifications
Country of Origin
United States
CSA Listed
Yes
ANSI Certified
Yes
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
How-To Articles
+
Manuals
+
 
 
×
Reznor RP-400 Gas Fired Duct Furnace - Power Vented - NG - 409 Stainless Steel Heat Exchanger - 400,000 BTU
Reznor RP-400-AC2
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile