Welcome:  Sign In | Contact Us
Call Us: (877) 326-3833

Panasonic - 26k BTU Cooling + Heating - Commercial Wall Mounted Air Conditioning System - 16.7 SEER

Panasonic - 26k BTU Cooling + Heating - Commercial Wall Mounted Air Conditioning System - 16.7 SEER
Our Price
Compare Prices
Shipping Info
Model: 26PEK2U6
$2,750.00
Factory-Direct
Ships in 2-5 Business Days
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping
Free Lift Gate Service - 
Add-Ons
 
Factory-Direct
Ships in 2-5 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Panasonic is a leading manufacturer of high quality electronic goods, and their air conditioners are no exception. Panasonic has over 53 years of air conditioning experience, allowing any consumer to purchase a Panasonic product knowing that the addition to their home or office will be efficient, reliable and easy to use. The 26PEK2U6 Mini Split Unit is a perfect example of Panasonic's engineering aptitude. Provide comforting air to all areas of the room with the air sweep feature. The louver moves up and down in the air outlet providing continuous comforting air while the outdoor condenser produces a soft whisper sound.
  • Automatic Heating and Cooling Changeover
  • After you set the temperature and functions you desire, just relax. If the room temperature gets higher, the unit will add some air and if the room gets cold, it will add some heat..
  • Self-Diagnosing
  • The 26PEK2U6 is equipped with a self-diagnosing function that makes it easier to troubleshoot malfunctions and ultimately save on service labor costs.
  • Power Failure Automatic Restart
  • Your preset programmed operation can be reactivated once power is restored after a power failure.
  • Air Sweep Control
  • This function controls the positions and movement of the louvers to direct the air in a sweeping motion, providing comfort in all parts of the room.
  • Hot Start
  • The heat pump will warm up before blowing air to prevent any cold drafts.
  • Dry Mode
  • Operation is precisely controlled according to room temperature so that the air is properly dehumidified.
  • Product Includes
    • (1) Panasonic - 26k BTU - CAC Outdoor Condenser - Single Zone Only (U-26PE1U6)
    • (1) Panasonic 26k BTU Wall Mounted Unit - For Single-Zone (S-26PK2U6)
    Product Note
    This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Wire - This durable, insulated wire provides power to your indoor unit from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system. Our convenient Mini Split Installation Starter Kits include all of the required accessories listed above. Starter kits can be added to your order from the accessories tab above.
Specifications
General Information
Type
Wall Mounted
Product Line
PK Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Number of Zones A zone is a room or area within a building that has its own temperature control.
1
Indoor Unit Size(s) Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (09 + 12) means the system includes a 9k BTU unit and a 12k BTU unit.
24
DOE Regional Compliance In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
3/8" x 5/8"
Performance
Cooling Capacity
24000 BTU
Heating Capacity
27600 BTU
SEER SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
16.7
HSPF HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.1
Cooling Power Input
2820 Watts
Heating Power Input
2490 Watts
Minimum Outdoor Temperature for Heating This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
0 F
Dimensions
Product Weight
160 Pounds
U-26PE1U6 Specifications
General Information
Type
Outdoor Condenser
Product Line
PEF Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Maximum Number of Zones
1
Multi-Zone Compatible
No
Installation Location
Outdoor
Performance
Nominal Capacity
26000 BTU
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
49 dB
Minimum Outdoor Temperature for Heating This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
0 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
30 Amps
Dimensions
Maximum Line Length
165 Feet
Liquid Connection Size
0.375 Inches
Suction Connection Size
0.625 Inches
Product Height
30.71875 Inches
Product Width
37 Inches
Product Depth
13.375 Inches
Product Weight
128 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
S-26PK2U6 Specifications
General Information
Type
Wall Mounted Unit
Product Line
PK Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
No
Remote Control
Wireless
Installation Location
Indoor
Performance
Nominal Capacity
26000 BTU
Moisture Removal
5.7 Pints/Hour
Maximum Air Flow
650 CFM
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
48 dB
Minimum Sound Level
38 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
0.375 Inches
Gas Connection Size
0.625 Inches
Product Height
11.8125 Inches
Product Width
41.9375 Inches
Product Depth
9.0625 Inches
Product Weight
32 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Features
Features
    Panasonic is a leading manufacturer of high quality electronic goods, and their air conditioners are no exception. Panasonic has over 53 years of air conditioning experience, allowing any consumer to purchase a Panasonic product knowing that the addition to their home or office will be efficient, reliable and easy to use. The 26PEK2U6 Mini Split Unit is a perfect example of Panasonic's engineering aptitude. Provide comforting air to all areas of the room with the air sweep feature. The louver moves up and down in the air outlet providing continuous comforting air while the outdoor condenser produces a soft whisper sound.
  • Automatic Heating and Cooling Changeover
  • After you set the temperature and functions you desire, just relax. If the room temperature gets higher, the unit will add some air and if the room gets cold, it will add some heat..
  • Self-Diagnosing
  • The 26PEK2U6 is equipped with a self-diagnosing function that makes it easier to troubleshoot malfunctions and ultimately save on service labor costs.
  • Power Failure Automatic Restart
  • Your preset programmed operation can be reactivated once power is restored after a power failure.
  • Air Sweep Control
  • This function controls the positions and movement of the louvers to direct the air in a sweeping motion, providing comfort in all parts of the room.
  • Hot Start
  • The heat pump will warm up before blowing air to prevent any cold drafts.
  • Dry Mode
  • Operation is precisely controlled according to room temperature so that the air is properly dehumidified.
  • Product Includes
    • (1) Panasonic - 26k BTU - CAC Outdoor Condenser - Single Zone Only (U-26PE1U6)
    • (1) Panasonic 26k BTU Wall Mounted Unit - For Single-Zone (S-26PK2U6)
    Product Note
    This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Wire - This durable, insulated wire provides power to your indoor unit from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system. Our convenient Mini Split Installation Starter Kits include all of the required accessories listed above. Starter kits can be added to your order from the accessories tab above.
Specifications
General Information
Type
Wall Mounted
Product Line
PK Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Number of Zones A zone is a room or area within a building that has its own temperature control.
1
Indoor Unit Size(s) Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (09 + 12) means the system includes a 9k BTU unit and a 12k BTU unit.
24
DOE Regional Compliance In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
3/8" x 5/8"
Performance
Cooling Capacity
24000 BTU
Heating Capacity
27600 BTU
SEER SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
16.7
HSPF HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.1
Cooling Power Input
2820 Watts
Heating Power Input
2490 Watts
Minimum Outdoor Temperature for Heating This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
0 F
Dimensions
Product Weight
160 Pounds
U-26PE1U6 Specifications
General Information
Type
Outdoor Condenser
Product Line
PEF Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Maximum Number of Zones
1
Multi-Zone Compatible
No
Installation Location
Outdoor
Performance
Nominal Capacity
26000 BTU
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
49 dB
Minimum Outdoor Temperature for Heating This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
0 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
30 Amps
Dimensions
Maximum Line Length
165 Feet
Liquid Connection Size
0.375 Inches
Suction Connection Size
0.625 Inches
Product Height
30.71875 Inches
Product Width
37 Inches
Product Depth
13.375 Inches
Product Weight
128 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
S-26PK2U6 Specifications
General Information
Type
Wall Mounted Unit
Product Line
PK Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
No
Remote Control
Wireless
Installation Location
Indoor
Performance
Nominal Capacity
26000 BTU
Moisture Removal
5.7 Pints/Hour
Maximum Air Flow
650 CFM
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
48 dB
Minimum Sound Level
38 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
0.375 Inches
Gas Connection Size
0.625 Inches
Product Height
11.8125 Inches
Product Width
41.9375 Inches
Product Depth
9.0625 Inches
Product Weight
32 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Product Specs
+
Specifications
General Information
Type
Wall Mounted
Product Line
PK Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Number of Zones A zone is a room or area within a building that has its own temperature control.
1
Indoor Unit Size(s) Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (09 + 12) means the system includes a 9k BTU unit and a 12k BTU unit.
24
DOE Regional Compliance In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
3/8" x 5/8"
Performance
Cooling Capacity
24000 BTU
Heating Capacity
27600 BTU
SEER SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
16.7
HSPF HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.1
Cooling Power Input
2820 Watts
Heating Power Input
2490 Watts
Minimum Outdoor Temperature for Heating This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
0 F
Dimensions
Product Weight
160 Pounds
U-26PE1U6 Specifications
General Information
Type
Outdoor Condenser
Product Line
PEF Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Maximum Number of Zones
1
Multi-Zone Compatible
No
Installation Location
Outdoor
Performance
Nominal Capacity
26000 BTU
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
49 dB
Minimum Outdoor Temperature for Heating This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
0 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
30 Amps
Dimensions
Maximum Line Length
165 Feet
Liquid Connection Size
0.375 Inches
Suction Connection Size
0.625 Inches
Product Height
30.71875 Inches
Product Width
37 Inches
Product Depth
13.375 Inches
Product Weight
128 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
S-26PK2U6 Specifications
General Information
Type
Wall Mounted Unit
Product Line
PK Series
Operating Mode Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
No
Remote Control
Wireless
Installation Location
Indoor
Performance
Nominal Capacity
26000 BTU
Moisture Removal
5.7 Pints/Hour
Maximum Air Flow
650 CFM
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
48 dB
Minimum Sound Level
38 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
0.375 Inches
Gas Connection Size
0.625 Inches
Product Height
11.8125 Inches
Product Width
41.9375 Inches
Product Depth
9.0625 Inches
Product Weight
32 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Panasonic - 26k BTU Cooling + Heating - Commercial Wall Mounted Air Conditioning System - 16.7 SEER
Panasonic Heating and Cooling 26PEK2U6
+
Reset View
Panasonic Heating and Cooling 26PEK2U6
Panasonic Heating and Cooling 26PEK2U6
Panasonic Heating and Cooling 26PEK2U6
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile