Answer:This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson Supply location near you.
How Do I Update My Pickup Location?
Answer:The nearest pickup location within a 50-mile radius is automatically chosen when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
How Do I Place a Local Pickup Order?
Answer:Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
When Can Items Be Picked Up?
Answer:Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Orders that have not been picked up within two business days may be cancelled. You should opt to have your items shipped if you are not able to pick them up promptly.
Who Can Pick Up My Order?
Answer:You will be prompted to enter the name, mobile phone, and email address of the person who will be picking up the order during checkout. We will use this information to ensure the order is picked up by an authorized individual.
Why Can't I Select Local Pickup for Some Items?
Answer:Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Why Can't I Select Shipping for Some Items?
Answer:Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Which Payment Methods Are Accepted?
Answer:Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Expert Recommended AccessoriesSelected by Bob, our Expert
Required Accessories9
These accessories are required to properly setup/install this product.
Optional Accessories10
Features
LG's newest addition to its Multi F MAX series is the LMU480HV mini split outdoor condenser. Using state of the art inverter technology the LMU480HV can provide efficient, ductless heating and Cooling to up to eight separate control zones in any home. As an outside unit, the LMU480HV is compatible with a long list of sleek indoor units, allowing it to be one of the most versatile heat pumps on the market.
Inverter Technology
LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
Gold Fin Protection
To ensure the reliability and longevity of the LMU480HV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
Quiet Design
Thanks to a brushless direct current motor and a twin rotary compressor, the LMU480HV is significantly quieter than traditional air conditioning systems. These components reduce mechanical sound, electrical sound, and vibrations within the unit.
Product Compatible With
LG LMN Wall Mounted Mini Split Indoor Units
LG LSN Wall Mounted Mini Split Indoor Units
LG LMN Wall Mounted Mini Split Indoor Units
LG LMAN Wall Mounted Designer Mini Split Indoor Units
LG LMCN Ceiling Cassette Mini Split Indoor Units
LG LMDN Concealed Duct Mini Split Indoor Units
LG LMHN Concealed Duct Mini Split Indoor Units
LG LMVN Vertical Air Handler Mini Split Indoor Units
Product Note
This product requires at least two compatible LG mini split indoor units and the following accessories for installation:
Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
Branch BoxAn LG branch box is required to connect this condenser to LG mini split indoor units.
Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
Outdoor Condenser Plastic Pad (Optional) - This pad provides an even surface, free of debris, on which to place your outdoor condenser.
Wall Bracket (Optional) - A simple and sturdy way to mount your outdoor condenser off of the ground.
Adding these accessories to your order will provide a complete, ready-to-install mini split system.
LG products include a 10-year warranty with the requirement that installation is completed by a licensed contractor and that the product is registered at https://lg-dfs-warranty.com/ within 60 days of installation.
Specifications
LMU480HV
Overview
Product Category
Mini Split System Components
UPC
048231366649
General Information
Type
Outdoor Condenser
Product Line
Multi F
Product Sub-line
MAX
Product Category
Mini Split System Components
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
8
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Installation Location
Outdoor
Branch Box Required Branch Box RequiredBy making a single connection to the outdoor condenser, a branch box can supply the right amount of refrigerant to multiple indoor units. Learn More
Yes
Performance
Cooling BTU
48000
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
56 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
40 Amps
Dimensions
Maximum Line Length
475.7 Feet
Gas Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
54 17/48 Inches
Product Width
37 29/48 Inches
Product Depth
15 3/4 Inches
Product Weight
214 Pounds
Shipping Weight
236 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
Reviews
(14)
LG LMU480HV Reviews & Ratings
Customer Photos and Videos
How-To Articles
How to Pick the Perfect Mini Split Ceiling Cassette Unit
Many of us like it when our heating and cooling equipment is out of sight and o...