Answer:This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson Supply location near you.
How Do I Update My Pickup Location?
Answer:The nearest pickup location within a 50-mile radius is automatically chosen when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
How Do I Place a Local Pickup Order?
Answer:Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
When Can Items Be Picked Up?
Answer:Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Orders that have not been picked up within two business days may be cancelled. You should opt to have your items shipped if you are not able to pick them up promptly.
Who Can Pick Up My Order?
Answer:You will be prompted to enter the name, mobile phone, and email address of the person who will be picking up the order during checkout. We will use this information to ensure the order is picked up by an authorized individual.
Why Can't I Select Local Pickup for Some Items?
Answer:Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Why Can't I Select Shipping for Some Items?
Answer:Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Which Payment Methods Are Accepted?
Answer:Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Hover to zoom
1 Of 5
+5
View All
Goodman - 2.0 Ton Cooling - 60k BTU/Hr Heating - Air Conditioner + Multi Speed Furnace Kit - 14.5 SEER - 96% AFUE - Upflow
Expert Recommended AccessoriesSelected by Ken, our Expert
Required Accessories9
These accessories are required to properly setup/install this product.
Optional Accessories10
Features
A Goodman central air and furnace kit is the perfect way to update your home\'s HVAC system. This kit contains a GSX14 air conditioner, a GM9S96 furnace, and a cased CAPFA evaporator coil making it the ideal solution for most parts of the country. It\'s the perfect kit for areas that use an average amount of cooling but want a multi-speed furnace for the long cold winters. Each of these components is designed with a focus on ease-of-installation and durability to provide you with upfront and long-term value. If you\'re looking for a complete comfort solution backed by superior craftsmanship, the Goodman GSX140241 GM9S960603BN CAPFA2422B6 air conditioner and furnace kit fits the bill perfectly.
High Efficiency Compressor
This unit utilizes a High Efficiency scroll compressor to provide refrigerant flow. Scroll compressors are renowned for operating more smoothly and reliably than traditional compressors.
Filter Drier
A filter drier is installed in the liquid line of this air conditioner. The filter drier removes moisture and traps impurities, preventing corrosion, freezing, and blockages that can negatively impact the operation of the air conditioner.
Advanced Heat Exchanger Design
The GM9S96 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
Quiet Comfort
The blower, motor, and gas valve of the GM9S96 were selected for their incredibly low sound levels. Additionally, this unit's fan speed options make it easy to maintain virtually silent circulation.
Venting Options
The GM9S96 offers several venting options to streamline installation in a variety of applications. It can be used in either a two-pipe direct vent setup or a single-pipe configuration with combustion air.
Easy Integration
The GM9S96 makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
All-Aluminum Coil
Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort.
Condensate Management
The included coil features foil-faced insulation to inhibit the formation of condensate and a rust-resistant thermoplastic drain pan to capture what does form, keeping your system safe and operational.
Extended Warranty
Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
(1) Goodman GSX14 - 2 Ton - Air Conditioner - 14 Nominal SEER - Single-Stage - R-410A Refrigerant (GSX140241)
(1) Goodman CAPF - 2 Ton - Upflow/Downflow A Coil - Cased - 17.5" Width (CAPFA2422B6)
Product Note
The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the \"Recommended Accessories\" tab. | The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help. NOTE: Due to DOE regulations, as of January 1st this unit can no longer be installed in the southwest and southeast DOE regions.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
(1) Goodman GSX14 - 2 Ton - Air Conditioner - 14 Nominal SEER - Single-Stage - R-410A Refrigerant (GSX140241)
(1) Goodman CAPF - 2 Ton - Upflow/Downflow A Coil - Cased - 17.5" Width (CAPFA2422B6)
GSX140241 GM9S960603BN CAPFA2422B6
Overview
Product Category
Furnace & Air Conditioner Package
General Information
Product Category
Furnace & Air Conditioner Package
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor Type
ECM Multi-Speed
Coil Width
17.5 Inches
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North
Installation Available
Yes
Subscription Eligible
No
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Cooling Capacity
23000 BTU
Nominal Cooling Capacity
24000 BTU
Heating BTU
60000
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.5
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
Fuel Type Fuel TypeTo create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Vent TypeProducts that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Modulating/StagingStages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor Type
ECM Multi-Speed
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
AFUE AFUEAFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Heating BTU
60000
High Fire Input
60000 BTU
High Fire Output
57660 BTU
Maximum Air Flow
1200 CFM
Ultra Low NOx Emissions Ultra Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Low NOx EmissionsNOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
10.3 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
118 Pounds
Shipping Weight
118 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
207349293
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling
Refrigerant Type
R-410a
Installation Location
Outdoor
Compressor Stages Compressor StagesStages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single Stage
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North
Installation Available
Yes
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Cooling BTU
24000
Cooling Capacity
24000 BTU
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
EER EEREER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.0
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
74 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
10 Amps
Recommended Breaker Size
15 Amps
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Product Height
27 1/2 Inches
Product Width
26 Inches
Product Depth
26 Inches
Product Weight
126 Pounds
Shipping Weight
141 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Configuration ConfigurationOrientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
TXV Installed
No
Performance
Capacity CapacityTonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Cooling BTU
24000
Nominal Minimum Cooling Capacity
24000 BTU
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
17 1/2 Inches
Product Height
22 Inches
Product Width
17 1/2 Inches
Product Depth
21 Inches
Product Weight
35 Pounds
Shipping Weight
45 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information