Goodman GPG13M - 4 Ton Cooling - 60,000 BTU Heating - Packaged Gas & Electric Central Air System

$500 Off eComfort Installation
Goodman GPG1448060M41
Goodman GPG13M - 4 Ton Cooling - 60,000 BTU Heating - Packaged Gas & Electric Central Air System
Our Price
Compare Prices
Shipping Info
Model: GPG1448060M41
(Based on expert analysis, manufacturer ratings and customer reviews)
4.4 out of 54.4 out of 54.4 out of 54.4 out of 54.4 out of 5
Number of Reviews (5)
Write A Review
$3,506.00
Add to Cart for Price

In-Stock
Ships Friday, Apr 10th
Shipping Crate Icon
Free Shipping
Free Lift Gate Service - 
Add-Ons
In-Stock
Ships Friday, Apr 10th
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Alaska, Hawaii or any destination outside of the United States
Share
  • Product Description
  • 5
    Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Specifications
    General Information
    Type
    Gas/Electric Packaged Unit
    Product Line
    GPG14
    Operating Mode Learn More
    Operating Mode
    Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
    Heating and Cooling
    Fuel Type Learn More
    Fuel Type
    To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
    Natural Gas
    Modulating/Staging Learn More
    Modulating/Staging
    Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
    Single Stage
    Refrigerant Type
    R-410A
    Blower Motor
    Multi-Speed
    Motor Type
    ECM
    Configuration Learn More
    Configuration
    Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
    Downflow/Horizontal
    Installation Location
    Outdoor
    Gas Conversion Kit
    Available
    Compressor Stages Learn More
    Compressor Stages
    Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
    Single
    DOE Regional Compliance Learn More
    DOE Regional Compliance
    In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
    Nationwide
    Installation Available
    Yes
    UPC
    663051518612
    Performance
    AFUE Learn More
    AFUE
    AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
    81 %
    Capacity Learn More
    Capacity
    Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
    4.0 Tons
    Cooling Capacity
    47000 BTU
    Heating Capacity
    60000 BTU
    SEER Learn More
    SEER
    SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
    14.0
    EER Learn More
    EER
    EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
    11.0
    Maximum Air Flow
    1780 CFM
    Minimum Air Flow
    1465 CFM
    Electrical Data
    Voltage
    208/230 Volts
    Phase
    1
    Frequency
    60 Hz
    Minimum Circuit Ampacity
    32 Amps
    Recommended Breaker Size
    50 Amps
    Dimensions
    Product Height
    42 3/4 Inches
    Product Width
    47 Inches
    Product Depth
    51 Inches
    Product Weight
    518 Pounds
    Shipping Weight
    540 Pounds
    Certifications
    ETL Listed
    Yes
    AHRI Certified
    Yes
    Warranty Information
    Parts Warranty Learn More
    Parts Warranty
    A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
    10 Limited Years
    Heat Exchanger Warranty
    20 Limited Years
    Compressor Warranty
    Limited* 10 Years
    Features
    Features
      Specifications
      General Information
      Type
      Gas/Electric Packaged Unit
      Product Line
      GPG14
      Operating Mode Learn More
      Operating Mode
      Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
      Heating and Cooling
      Fuel Type Learn More
      Fuel Type
      To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
      Natural Gas
      Modulating/Staging Learn More
      Modulating/Staging
      Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
      Single Stage
      Refrigerant Type
      R-410A
      Blower Motor
      Multi-Speed
      Motor Type
      ECM
      Configuration Learn More
      Configuration
      Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
      Downflow/Horizontal
      Installation Location
      Outdoor
      Gas Conversion Kit
      Available
      Compressor Stages Learn More
      Compressor Stages
      Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
      Single
      DOE Regional Compliance Learn More
      DOE Regional Compliance
      In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
      Nationwide
      Installation Available
      Yes
      UPC
      663051518612
      Performance
      AFUE Learn More
      AFUE
      AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
      81 %
      Capacity Learn More
      Capacity
      Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
      4.0 Tons
      Cooling Capacity
      47000 BTU
      Heating Capacity
      60000 BTU
      SEER Learn More
      SEER
      SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
      14.0
      EER Learn More
      EER
      EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
      11.0
      Maximum Air Flow
      1780 CFM
      Minimum Air Flow
      1465 CFM
      Electrical Data
      Voltage
      208/230 Volts
      Phase
      1
      Frequency
      60 Hz
      Minimum Circuit Ampacity
      32 Amps
      Recommended Breaker Size
      50 Amps
      Dimensions
      Product Height
      42 3/4 Inches
      Product Width
      47 Inches
      Product Depth
      51 Inches
      Product Weight
      518 Pounds
      Shipping Weight
      540 Pounds
      Certifications
      ETL Listed
      Yes
      AHRI Certified
      Yes
      Warranty Information
      Parts Warranty Learn More
      Parts Warranty
      A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
      10 Limited Years
      Heat Exchanger Warranty
      20 Limited Years
      Compressor Warranty
      Limited* 10 Years
      Product Specs
      +
      Specifications
      General Information
      Type
      Gas/Electric Packaged Unit
      Product Line
      GPG14
      Operating Mode Learn More
      Operating Mode
      Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
      Heating and Cooling
      Fuel Type Learn More
      Fuel Type
      To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
      Natural Gas
      Modulating/Staging Learn More
      Modulating/Staging
      Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
      Single Stage
      Refrigerant Type
      R-410A
      Blower Motor
      Multi-Speed
      Motor Type
      ECM
      Configuration Learn More
      Configuration
      Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
      Downflow/Horizontal
      Installation Location
      Outdoor
      Gas Conversion Kit
      Available
      Compressor Stages Learn More
      Compressor Stages
      Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
      Single
      DOE Regional Compliance Learn More
      DOE Regional Compliance
      In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
      Nationwide
      Installation Available
      Yes
      UPC
      663051518612
      Performance
      AFUE Learn More
      AFUE
      AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
      81 %
      Capacity Learn More
      Capacity
      Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
      4.0 Tons
      Cooling Capacity
      47000 BTU
      Heating Capacity
      60000 BTU
      SEER Learn More
      SEER
      SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
      14.0
      EER Learn More
      EER
      EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
      11.0
      Maximum Air Flow
      1780 CFM
      Minimum Air Flow
      1465 CFM
      Electrical Data
      Voltage
      208/230 Volts
      Phase
      1
      Frequency
      60 Hz
      Minimum Circuit Ampacity
      32 Amps
      Recommended Breaker Size
      50 Amps
      Dimensions
      Product Height
      42 3/4 Inches
      Product Width
      47 Inches
      Product Depth
      51 Inches
      Product Weight
      518 Pounds
      Shipping Weight
      540 Pounds
      Certifications
      ETL Listed
      Yes
      AHRI Certified
      Yes
      Warranty Information
      Parts Warranty Learn More
      Parts Warranty
      A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
      10 Limited Years
      Heat Exchanger Warranty
      20 Limited Years
      Compressor Warranty
      Limited* 10 Years
      Reviews
      (5)
      +
      Goodman GPG1448060M41 Reviews & Ratings
      Product Q&A
      +
      Be the first to ask a question.
      Recommended Accessories
      +
      Expert Recommended Accessories Hand Picked By Our Expert Chris
      icon-social-fb1
      Required Accessories Add All Required
      Optional Accessories
      How-To Articles
      +
      Manuals
      +
       
       
      ×
      Goodman GPG13M - 4 Ton Cooling - 60,000 BTU Heating - Packaged Gas & Electric Central Air System
      Goodman GPG1448060M41
      +
      Reset View
      ×
      Customer Review Images