Model: IN5PVNI-M2
$3,495.00
Factory-Direct
Ships in 7-14 Business Days
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping
Free Lift Gate Service - 
Add-Ons
 
Factory-Direct
Ships in 7-14 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to California, Texas, Utah or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • 1
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Burnham is devoted to pushing the limits of heating technology and efficiency. Their ingenuity is responsible for some of the most efficient boilers on the market today. The Independence line brings reliability and simplicity to the forefront. Burnham's Independence PV boilers are an efficient, low profile solution for your hydronic heating needs. With an Independence PV you will get all the benefits of an Independence boiler, but in a power vent system. The large water volume of Independence boilers means that they are suited for a variety of applications. The IN5PVNI-M2 has an insulated jacket that covers the gas valves and burner to improve not just heat retention and efficiency but safety as well. High quality Honeywell controls are also concealed within the jacket. If you are looking for a well-rounded, dependable steam boiler, you don't need to look further than the Independence PV.
  • Venting Technology
  • Instead of venting through a chimney, Independence PV boilers use a fan and vent directly through your wall. This fan draws combustion air into the boiler and over the heat exchanger, improving efficiency.
  • Durable Construction
  • Cast-iron construction of the boiler sections and stainless steel burners contribute to the incredible longevity of Independence PV models. The heat exchanger is also made of cast iron, which allows it to accept lower return water temperatures.
  • Product Includes
  • (1) Burnham IN5PVNI-M2 Steam Boiler
  • (1) Induced Draft Fan
  • (1) Instruction Envelope
Specifications
General Information
Product Line
Independence PV
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Heat Exchanger Material
Cast Iron
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Gas Conversion Kit
Not Convertible
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
116000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
87000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82.2 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
0.5 Inches
Supply Connection
2 Inches
Return Connection
2 Inches
Product Height
45 Inches
Product Width
21 Inches
Product Depth
25 Inches
Shipping Weight
490 Pounds
Certifications
Country of Origin
United States
AHRI Certified
Yes
AHRI Reference Number
2101395
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Features
Features
    Burnham is devoted to pushing the limits of heating technology and efficiency. Their ingenuity is responsible for some of the most efficient boilers on the market today. The Independence line brings reliability and simplicity to the forefront. Burnham's Independence PV boilers are an efficient, low profile solution for your hydronic heating needs. With an Independence PV you will get all the benefits of an Independence boiler, but in a power vent system. The large water volume of Independence boilers means that they are suited for a variety of applications. The IN5PVNI-M2 has an insulated jacket that covers the gas valves and burner to improve not just heat retention and efficiency but safety as well. High quality Honeywell controls are also concealed within the jacket. If you are looking for a well-rounded, dependable steam boiler, you don't need to look further than the Independence PV.
  • Venting Technology
  • Instead of venting through a chimney, Independence PV boilers use a fan and vent directly through your wall. This fan draws combustion air into the boiler and over the heat exchanger, improving efficiency.
  • Durable Construction
  • Cast-iron construction of the boiler sections and stainless steel burners contribute to the incredible longevity of Independence PV models. The heat exchanger is also made of cast iron, which allows it to accept lower return water temperatures.
  • Product Includes
  • (1) Burnham IN5PVNI-M2 Steam Boiler
  • (1) Induced Draft Fan
  • (1) Instruction Envelope
Specifications
General Information
Product Line
Independence PV
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Heat Exchanger Material
Cast Iron
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Gas Conversion Kit
Not Convertible
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
116000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
87000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82.2 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
0.5 Inches
Supply Connection
2 Inches
Return Connection
2 Inches
Product Height
45 Inches
Product Width
21 Inches
Product Depth
25 Inches
Shipping Weight
490 Pounds
Certifications
Country of Origin
United States
AHRI Certified
Yes
AHRI Reference Number
2101395
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Product Specs
+
Specifications
General Information
Product Line
Independence PV
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Heat Exchanger Material
Cast Iron
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Power Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Assembly Type
Packaged
Gas Conversion Kit
Not Convertible
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
116000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
87000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82.2 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
0.5 Inches
Supply Connection
2 Inches
Return Connection
2 Inches
Product Height
45 Inches
Product Width
21 Inches
Product Depth
25 Inches
Shipping Weight
490 Pounds
Certifications
Country of Origin
United States
AHRI Certified
Yes
AHRI Reference Number
2101395
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
(1)
+
Search Product Q&A's Answered by Bob, the Heating Product Expert
icon-social-fb1
+
Under what conditions would I need a "fan in a can" for this unit to work properly? Do I need to re-line my old chimney (interior location, clay lined)?
Arthur 
from Massachusetts 
March 30, 2016
Answer
You would need a "Fan in a Can" or other power exhaust system if your chimney is not suitable for use with the IN7 boiler in your inquiry. You will need to have a on-site professional inspect your existing chimney to determine if it is appropriate and if any repairs/updates are needed.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Burnham IN5PVNI - 87K BTU - 82.2% AFUE - Steam Gas Boiler - Power Vent - Packaged with Trim
Burnham IN5PVNI-M2
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile