Williams AC3040TP
Williams AC3040TP
Hover to zoom
1 Of 5

Williams - 40k BTU - Gas Top Vent - Wall Furnace - LP - 80% AFUE - Double Sided

Model:

AC3040TP

Write A Review
$3,339.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
Out of Stock
Sorry, this product is currently unavailable.
Continue Shopping With These Categories
Williams - 40k BTU - Gas Top Vent - Wall Furnace - LP - 80% AFUE - Double Sided
Williams - 40k BTU - Gas Top Vent - Wall Furnace - LP - 80% AFUE - Double Sided
Model: AC3040TP
$3,339.00
Out of Stock
Accessories
Features
Specifications
Reviews
Product Q&A
How-To Articles
Manuals
Share

Recommended Accessories

eComfort expert image
Expert Recommended Accessories Selected by Ken, our Expert
Required Accessories 9
These accessories are required to properly setup/install this product.
Optional Accessories 10

Features

    The AC3040TP top vent gas wall heater is the next generation high performance vented wall furnace heating solution. The AC3040TP offers traditional home comfort by lowering heating costs, adding convenience and high efficiency. Individual rooms can also be heated comfortably while saving on fuel costs in unused areas. The AC3040TP can be recessed or surface-mounted and are great in homes, schools, cabins, apartments, offices and shops.
  • Superior Comfort and Efficiency
  • Sustainable 80% AFUE ultra-low NOx emissions.
  • Dynamic Response
  • Energy savings and constant comfortable temperature or just enough heat for your desired environment.
  • No Standing Pilot
  • Eliminates seasonal relighting, saves energy and eliminates methane emissions.
  • Quiet Fans
  • Offer improved comfort and air circulation.
  • Reduced Carbon Footprint
  • Fits into the same opening and uses the same venting as the traditional Monterey wall furnace.
  • Programmable thermostat included for energy savings and comfort
  • Multiple Heating Schedule and Temperatures, BTU Output, Date and Time and Manual and Auto Modes.
  • Product Note
    A programmable thermostat is included with this unit. Product dimensions reflect measurement of furnace coming out from the wall.
California residents see
Warning: This product can expose you to chemicals including Epichlorohydrin which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

AC3040TP
specs product image PID-124699
General Information
Type
Gas Wall Furnace
Product Category
Furnace
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Top Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Gas Conversion Kit
Available
UPC
093909006716
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
40000
High Fire Input
40000 BTU
High Fire Output
33727 BTU
Dimensions
Gas Connection Size
1/2 Inch
Product Height
65 3/4 Inches
Product Width
16 Inches
Product Depth
6 Inches
Product Weight
145 Pounds
Shipping Weight
165 Pounds
Certifications
CSA Listed
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year

Reviews

Williams AC3040TP Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How Gas Furnaces Work
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
Modulating, Single Stage & Two Stage Furnaces
Modulating, Single Stage & Two Stage Furnaces
Think back to a time when you were playing a sport. If you’re like me, yo...
How to Pick the Perfect Furnace
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Williams - 40k BTU - Gas Top Vent - Wall Furnace - LP - 80% AFUE - Double Sided
Williams AC3040TP
Customer Review Images