Williams 6008832
Williams 6008832
Hover to zoom
1 Of 5
Williams Magnum High-Efficiency - 60K BTU - Gas Top-Vent Wall Furnace - 76% AFUE - Standing Pilot
Model: 6008832
4.7 out of 54.7 out of 54.7 out of 54.7 out of 54.7 out of 5
Number of Reviews(21)
Write a Review
$1,300.00
Free Shipping
&
Lift Gate
  Learn More About Free Freight
Free Shipping & Lift Gate
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
In-Stock
Ships in 1-3 Business Days
Shipping to60601
Shipping Details
  • Lift Gate Service Available - Free Lift Gate Learn More
*We currently CANNOT ship this product to Canada or any destination outside of the United States

Available Add-Ons
FREE
Learn More
Lift Gate Service
All products weighing more than 100 lbs. ship via semi-truck. We recommend ordering the Lift Gate Service to safely lower the product to the curb. If you have a loading dock or forklift, you do NOT need a Lift Gate service. If you are a residential customer, you must have at least 2-4 able-bodied people present to unload the product. Learn More
Share
  • Product Description
  • 21
    Reviews
  • 3
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Requiring less than one square foot for installation, the Williams Forsaire High-Efficiency wall furnace can be surface mounted or recessed into a stud bay for even more space savings. Simply place it where you want it and vent it vertically through the ceiling and roof. Whether recessed into the wall or surface mounted, the soft-white powder coated finish provides a discrete durable finish that blends into any home's decor.
  • Counterflow Blower System
  • The Forsaire furnace has a counterflow blower system that takes air from the ceiling and blows the warm air at the floor. This allows for the heat to be evenly distributed throughout the room.
  • Safe Pilot Ignition
  • With matchless pilot ignition, the guess work is taken out of lighting the furnace. By sealing the pilot and igniter away from dirt and debris, the electronic igniter lights the furnace safely and reliably.
  • Vent Limit Safety Switch
  • The vent limit safety switch is equipped on all Forsaire furnaces. This turns off the unit in case the vent is blocked, protecting your family from carbon monoxide and fires.
  • Optional Multi-room Heating
  • Supply an adjacent room with heat using the optional rear or side outlet kits.
  • Product Note
    A thermostat does not come included with this unit. The Williams P322016 thermostat is compatible and can be found under the "Accessories" tab. Alternatively, any standard millivolt thermostat can be used.
Specifications
General Information
Type
Gas Wall Furnace
Product Line
Forsaire
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
PSC Multi-Speed
Mount Type
Wall
Gas Conversion Kit
Available
Installation Available
No
UPC
0093909299309
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
76 %
Heating BTU
60000
High Fire Input
60000 BTU
High Fire Output
45500 BTU
Maximum Air Flow
440 CFM
Electrical Data
Minimum Circuit Ampacity
33 Amps
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
4 Inches
Product Height
80 1/4 Inches
Product Width
14 1/8 Inches
Product Depth
12 Inches
Product Weight
111 Pounds
Shipping Weight
121 Pounds
Certifications
CSA Listed
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Features
Features
    Requiring less than one square foot for installation, the Williams Forsaire High-Efficiency wall furnace can be surface mounted or recessed into a stud bay for even more space savings. Simply place it where you want it and vent it vertically through the ceiling and roof. Whether recessed into the wall or surface mounted, the soft-white powder coated finish provides a discrete durable finish that blends into any home's decor.
  • Counterflow Blower System
  • The Forsaire furnace has a counterflow blower system that takes air from the ceiling and blows the warm air at the floor. This allows for the heat to be evenly distributed throughout the room.
  • Safe Pilot Ignition
  • With matchless pilot ignition, the guess work is taken out of lighting the furnace. By sealing the pilot and igniter away from dirt and debris, the electronic igniter lights the furnace safely and reliably.
  • Vent Limit Safety Switch
  • The vent limit safety switch is equipped on all Forsaire furnaces. This turns off the unit in case the vent is blocked, protecting your family from carbon monoxide and fires.
  • Optional Multi-room Heating
  • Supply an adjacent room with heat using the optional rear or side outlet kits.
  • Product Note
    A thermostat does not come included with this unit. The Williams P322016 thermostat is compatible and can be found under the "Accessories" tab. Alternatively, any standard millivolt thermostat can be used.
Specifications
General Information
Type
Gas Wall Furnace
Product Line
Forsaire
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
PSC Multi-Speed
Mount Type
Wall
Gas Conversion Kit
Available
Installation Available
No
UPC
0093909299309
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
76 %
Heating BTU
60000
High Fire Input
60000 BTU
High Fire Output
45500 BTU
Maximum Air Flow
440 CFM
Electrical Data
Minimum Circuit Ampacity
33 Amps
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
4 Inches
Product Height
80 1/4 Inches
Product Width
14 1/8 Inches
Product Depth
12 Inches
Product Weight
111 Pounds
Shipping Weight
121 Pounds
Certifications
CSA Listed
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Product Specs
+
Specifications
General Information
Type
Gas Wall Furnace
Product Line
Forsaire
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
PSC Multi-Speed
Mount Type
Wall
Gas Conversion Kit
Available
Installation Available
No
UPC
0093909299309
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
76 %
Heating BTU
60000
High Fire Input
60000 BTU
High Fire Output
45500 BTU
Maximum Air Flow
440 CFM
Electrical Data
Minimum Circuit Ampacity
33 Amps
Dimensions
Gas Connection Size
1/2 Inch
Flue Connection Size
4 Inches
Product Height
80 1/4 Inches
Product Width
14 1/8 Inches
Product Depth
12 Inches
Product Weight
111 Pounds
Shipping Weight
121 Pounds
Certifications
CSA Listed
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Reviews
(21)
+
Williams 6008832 Reviews & Ratings
100% of Reviewers Recommend This Product
Product Q&A
(3)
+
Search Product Q&A's Answered by Bob, the Heating Product Expert
icon-social-fb1
+
Will this work on propane?
Cody 
from California 
January 29, 2020
Answer
There is a conversion kit available for this model to allow it to work on propane. The proper NG to LP kit is 7724
Was this answer helpful?
Yes
Thumbs Up Icon
1
No
Thumbs Down Icon
0
+
Is this furnace one or two stage?
Bill 
from California 
February 12, 2019
Answer
This is a two-stage furnace.
Was this answer helpful?
Yes
Thumbs Up Icon
1
No
Thumbs Down Icon
1
+
What is a standing pilot?
Bill 
from California 
February 12, 2019
Answer
A standing pilot means that the pilot flame will consistently burn for ignition instead of sparking.
Was this answer helpful?
Yes
Thumbs Up Icon
1
No
Thumbs Down Icon
0
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
Media Gallery
Williams Magnum High-Efficiency - 60K BTU - Gas Top-Vent Wall Furnace - 76% AFUE - Standing Pilot
Williams 6008832
+
Reset View
×
Customer Review Images