Features

    Viessmann offers a comprehensive range of home comfort products that sets the standards for sustainability and efficiency. Big brother to the Vitodens 100, the Vitodens 200 is the same highly efficient and dependable boiler with the addition of an enhanced combustion system and control unit. These additional components ensure optimal performance and efficiency around the clock. Equipped with state-of-the-art Viessmann radial heat exchangers and cylinder burners, the entire Vitodens lineup boasts a 95% AFUE rating. With versatile venting options and user-friendly controls, the Vitodens 200 is a favorite among professionals and homeowners alike.
  • Ultra Low NOx
  • Some states require that every newly installed boiler emits less than 14 ng/J of NOx gases, a toxic byproduct of combustion. The Viessmann B2HB690 boiler features Ultra Low NOx emissions, conforming to this regulation.
  • Inox-Radial Heat Exchanger
  • The Vitodens 200 boiler features a unique and highly efficient Inox-Radial heat exchanger designed and manufactured by Viessmann. Additionally, this self-cleaning heat exchanger contributes to the Vitodens's long service life and dependable performance.
  • Lambda Pro Combustion Management System
  • Equipped with the state-of-the-art Lambda Pro combustion management system, the Vitodens 200 adapts combustion to changing gas qualities and operating conditions to optimize performance and efficiency.
  • Award-Winning Control Unit
  • The Viessmann-made Vitotronic 200, HO1B control manages the entire heating system and ensures maximum performance and comfort at all times. This user-friendly control features a backlit display, multi-line text and graphics for hassle-free boiler control.
  • Outdoor Reset
  • The Vitotronic 200 control includes an outdoor reset mode that can reduce fuel consumption up to 15%. The outdoor reset adapts the boiler's operating temperature to the changing outdoor temperature, allowing for excellent returns on an initial investment.
  • Installation and Service Flexibility
  • The Vitodens 200 was designed for ease of installation and maintenance with all bottom pipe connections, accessible service components, fuel flexibility and multiple venting options.

Specifications

B2HB690
specs product image PID-102761
General Information
Product Line
Vitodens
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production Learn More
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
No
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
125000 BTU
Minimum Input Capacity
19000 BTU
DOE Heating Capacity Learn More
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
117000 BTU
Net I=B=R Capacity Learn More
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
102000 BTU
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Turndown Ratio
6.5:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
2.375 Inches
Gas Connection Size
3/4 Inch
Boiler Supply
3/4 Inch
Boiler Return
3/4 Inch
Product Height
41 Inches
Product Width
17 3/4 Inches
Product Depth
15 17/24 Inches
Product Weight
110 Pounds
Shipping Weight
120 Pounds
Certifications
CSA Listed
Yes
Energy Star Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
10594289
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
10 Years

Reviews

Viessmann B2HB690 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How to Pick the Perfect Boiler
How to Pick the Perfect Boiler
At the heart of every boiler heating system is the boiler itself. It's responsi...
A Break-Down of Boiler Fuel Options
A Break-Down of Boiler Fuel Options
In many homes around the world, having a boiler is essential. A boiler can prov...
Hydronic System Accessory Guide
Hydronic System Accessory Guide
How warm does a coat keep you without gloves and a hat? Accessories are sometim...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Viessmann Vitodens 200 - 125K BTU - 95% AFUE - Hot Water Gas Boiler - Ultra Low NOx
Viessmann B2HB690
Customer Review Images