Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Revolv - 4.0 Ton Cooling - 72k BTU/Hr Heating - Air Conditioner + High Efficiency Furnace Kit - 14.0 SEER - 95% AFUE - For Downflow Installation

Revolv - 4.0 Ton Cooling - 72k BTU/Hr Heating - Air Conditioner + High Efficiency Furnace Kit - 14.0 SEER - 95% AFUE - For Downflow Installation
Our Price
Compare Prices
Shipping Info
Model: RSC1448RG772D
$3,385.00
Ships in 2-5 Business Days
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Add-Ons
 
Ships in 2-5 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to California or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. Designed for easy installation in mobile and manufactured housing, these units are specifically designed to fit into tight spaces and operate with minimum combustion clearances. The RSC1448RG772D provides you with a efficient air conditioner and a high efficient furnace. The RG7 Furnaces have an amazing 95% AFUE rating while the RSC14 air conditioners meet the standards nationwide. If you use heating and cooling equally, then this is the kit for you
  • High Efficiency Heating
  • RG7 furnaces are designed to save you money. Sporting a 95% AFUE efficiency rating, Revolv's high efficiency line will provide heat while keeping money in your pocket.
  • Multi-Speed Fan Settings
  • The high efficiency furnaces feature PSC multi-speed motors and direct drive blowers. These allow the unit to run at pre-set speeds to help regulate heating.
  • AccuCharge® with FitRight® Fittings
  • All AccuCharge® units come with a factory precise refrigerant charge and FitRight® fittings that provide an easy installation. The combination of the two are engineered for superior efficiency and reliability.
  • Corrosion Resistant Finish
  • The Revolv AccuCharge® air conditioners are made out of a galvanized steel with a polyester urethane coat finish. They are then sprayed with a 950 hour salt finish that has a 50% better corrosion resistant rating than comparable units.
  • Composite Base Pan
  • A composite base pan is stronger and lighter than your standard steel base pan. Being composite, it absorbs sound better and is also corrosion resistant.
  • Sealed Combustion
  • Revolv RG7 furnaces vent directly to the outdoors and draw in fresh air for combustion through a separately purchased roof jack.
  • Compact Design
  • All Revolv furnaces are designed specifically for manufactured and modular homes. This allows them to be installed in utility rooms or closets and streamlines installation.
  • High Quality, Low Maintenance
  • Features such as hot surface ignition, sealed bearings on the motors, reliable controllers, and a clean enamel finish means these units are made to last and provide uninterrupted comfort for years.
  • Factory Installed TXV Valve
  • The AccuCharge® coils come installed with a thermal expansion valve (TXV) that helps control the amount of refrigerant flow into the evaporator.
  • Failure Prevention
  • AccuCharge® coils have features to prevent premature failure of your coil. It has a built-in strainer to prevent debris from entering the coil. It also has a dry-type pan so that it doesn't hold standing water.
  • Product Includes
    • (1) Revolv AccuCharge® - 4.0 Ton - Air Conditioner - Manufactured Home - 14.0 Nominal SEER - Single-Stage - R-410a Refrigerant (RSCQ484)
    • (1) Revolv RG7 - 72k BTU - Gas-Fired Furnace - Manufactured Home - NG - 95% AFUE - Single-Stage - Downflow - Multi-Speed (RG7D72N4)
    • (1) Revolv AccuCharge® M-Series - 3-4 Ton - Downflow A Coil - Uncased (187848M4A)
    • (1) Revolv - Coil Cabinet - Manufactured Home - 26" Height - For RG1 and RG7 Furnaces (922594)
    Product Note
    The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help.
Specifications
General Information
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling and Heating
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
44000 BTU
Heating Capacity
68400 BTU
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.2
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Certifications
AHRI Certified
Yes
RSCQ484 Specifications
General Information
Type
Outdoor Condenser
Product Line
AccuCharge
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling Only
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages ? Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Nominal Capacity
48000 BTU
Heating Capacity
48000 BTU
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Nominal Cooling Capacity
48000 BTU
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.2
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
78 dB
Nominal SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Actual SEER may differ from Nominal SEER depending on the products used in a particular system.
14.0
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
45 Amps
Dimensions
Product Height
41 1/4 Inches
Product Width
31 3/4 Inches
Product Depth
31 3/4 Inches
Product Weight
206 Pounds
Liquid Valve Connection Size
3/8 Inch
Suction Valve Connection Size
7/8 Inch
Certifications
Energy Star Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
RG7D72N4 Specifications
General Information
Type
Gas Furnace
Product Line
RG7
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Type ? Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
PSC Multi-Speed
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Maximum Altitude
2000 Feet
Gas Conversion Kit
Included
Performance
Heating Capacity
68400 BTU
Nominal Heating Capacity
72000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95.1 %
Minimum Air Flow
900 CFM
Maximum Air Flow
1555 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Gas Connection Size
1/2 Inch
Product Height
56 Inches
Product Width
19 7/8 Inches
Product Depth
18 1/2 Inches
Shipping Height
155 Inches
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
8862050
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
10 Years
187848M4A Specifications
General Information
Type
Evaporator Coil
Product Line
AccuCharge
Refrigerant Type
R-410a
Casing
Uncased
Shape
A Coil
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Performance
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Nominal Cooling Capacity
48000 BTU
Dimensions
Liquid Connection Size
3/8 Inch
Gas Connection Size
7/8 Inch
Product Height
19 1/2 Inches
Product Width
18 Inches
Product Depth
19 5/8 Inches
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
922594 Specifications
General Information
Type
Coil Cabinet
Dimensions
Product Height
26 Inches
Product Width
19 3/4 Inches
Product Depth
23 3/4 Inches
Features
Features
    Revolv is dedicated to bringing efficient comfort to the manufactured and mobile home market. Designed for easy installation in mobile and manufactured housing, these units are specifically designed to fit into tight spaces and operate with minimum combustion clearances. The RSC1448RG772D provides you with a efficient air conditioner and a high efficient furnace. The RG7 Furnaces have an amazing 95% AFUE rating while the RSC14 air conditioners meet the standards nationwide. If you use heating and cooling equally, then this is the kit for you
  • High Efficiency Heating
  • RG7 furnaces are designed to save you money. Sporting a 95% AFUE efficiency rating, Revolv's high efficiency line will provide heat while keeping money in your pocket.
  • Multi-Speed Fan Settings
  • The high efficiency furnaces feature PSC multi-speed motors and direct drive blowers. These allow the unit to run at pre-set speeds to help regulate heating.
  • AccuCharge® with FitRight® Fittings
  • All AccuCharge® units come with a factory precise refrigerant charge and FitRight® fittings that provide an easy installation. The combination of the two are engineered for superior efficiency and reliability.
  • Corrosion Resistant Finish
  • The Revolv AccuCharge® air conditioners are made out of a galvanized steel with a polyester urethane coat finish. They are then sprayed with a 950 hour salt finish that has a 50% better corrosion resistant rating than comparable units.
  • Composite Base Pan
  • A composite base pan is stronger and lighter than your standard steel base pan. Being composite, it absorbs sound better and is also corrosion resistant.
  • Sealed Combustion
  • Revolv RG7 furnaces vent directly to the outdoors and draw in fresh air for combustion through a separately purchased roof jack.
  • Compact Design
  • All Revolv furnaces are designed specifically for manufactured and modular homes. This allows them to be installed in utility rooms or closets and streamlines installation.
  • High Quality, Low Maintenance
  • Features such as hot surface ignition, sealed bearings on the motors, reliable controllers, and a clean enamel finish means these units are made to last and provide uninterrupted comfort for years.
  • Factory Installed TXV Valve
  • The AccuCharge® coils come installed with a thermal expansion valve (TXV) that helps control the amount of refrigerant flow into the evaporator.
  • Failure Prevention
  • AccuCharge® coils have features to prevent premature failure of your coil. It has a built-in strainer to prevent debris from entering the coil. It also has a dry-type pan so that it doesn't hold standing water.
  • Product Includes
    • (1) Revolv AccuCharge® - 4.0 Ton - Air Conditioner - Manufactured Home - 14.0 Nominal SEER - Single-Stage - R-410a Refrigerant (RSCQ484)
    • (1) Revolv RG7 - 72k BTU - Gas-Fired Furnace - Manufactured Home - NG - 95% AFUE - Single-Stage - Downflow - Multi-Speed (RG7D72N4)
    • (1) Revolv AccuCharge® M-Series - 3-4 Ton - Downflow A Coil - Uncased (187848M4A)
    • (1) Revolv - Coil Cabinet - Manufactured Home - 26" Height - For RG1 and RG7 Furnaces (922594)
    Product Note
    The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help.
Specifications
General Information
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling and Heating
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
44000 BTU
Heating Capacity
68400 BTU
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.2
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Certifications
AHRI Certified
Yes
RSCQ484 Specifications
General Information
Type
Outdoor Condenser
Product Line
AccuCharge
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling Only
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages ? Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Nominal Capacity
48000 BTU
Heating Capacity
48000 BTU
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Nominal Cooling Capacity
48000 BTU
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.2
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
78 dB
Nominal SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Actual SEER may differ from Nominal SEER depending on the products used in a particular system.
14.0
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
45 Amps
Dimensions
Product Height
41 1/4 Inches
Product Width
31 3/4 Inches
Product Depth
31 3/4 Inches
Product Weight
206 Pounds
Liquid Valve Connection Size
3/8 Inch
Suction Valve Connection Size
7/8 Inch
Certifications
Energy Star Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
RG7D72N4 Specifications
General Information
Type
Gas Furnace
Product Line
RG7
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Type ? Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
PSC Multi-Speed
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Maximum Altitude
2000 Feet
Gas Conversion Kit
Included
Performance
Heating Capacity
68400 BTU
Nominal Heating Capacity
72000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95.1 %
Minimum Air Flow
900 CFM
Maximum Air Flow
1555 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Gas Connection Size
1/2 Inch
Product Height
56 Inches
Product Width
19 7/8 Inches
Product Depth
18 1/2 Inches
Shipping Height
155 Inches
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
8862050
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
10 Years
187848M4A Specifications
General Information
Type
Evaporator Coil
Product Line
AccuCharge
Refrigerant Type
R-410a
Casing
Uncased
Shape
A Coil
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Performance
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Nominal Cooling Capacity
48000 BTU
Dimensions
Liquid Connection Size
3/8 Inch
Gas Connection Size
7/8 Inch
Product Height
19 1/2 Inches
Product Width
18 Inches
Product Depth
19 5/8 Inches
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
922594 Specifications
General Information
Type
Coil Cabinet
Dimensions
Product Height
26 Inches
Product Width
19 3/4 Inches
Product Depth
23 3/4 Inches
Product Specs
+
Specifications
General Information
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling and Heating
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
44000 BTU
Heating Capacity
68400 BTU
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.2
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Certifications
AHRI Certified
Yes
RSCQ484 Specifications
General Information
Type
Outdoor Condenser
Product Line
AccuCharge
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling Only
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages ? Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Nominal Capacity
48000 BTU
Heating Capacity
48000 BTU
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Nominal Cooling Capacity
48000 BTU
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.2
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
78 dB
Nominal SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Actual SEER may differ from Nominal SEER depending on the products used in a particular system.
14.0
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
45 Amps
Dimensions
Product Height
41 1/4 Inches
Product Width
31 3/4 Inches
Product Depth
31 3/4 Inches
Product Weight
206 Pounds
Liquid Valve Connection Size
3/8 Inch
Suction Valve Connection Size
7/8 Inch
Certifications
Energy Star Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
RG7D72N4 Specifications
General Information
Type
Gas Furnace
Product Line
RG7
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Type ? Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
PSC Multi-Speed
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Maximum Altitude
2000 Feet
Gas Conversion Kit
Included
Performance
Heating Capacity
68400 BTU
Nominal Heating Capacity
72000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95.1 %
Minimum Air Flow
900 CFM
Maximum Air Flow
1555 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Gas Connection Size
1/2 Inch
Product Height
56 Inches
Product Width
19 7/8 Inches
Product Depth
18 1/2 Inches
Shipping Height
155 Inches
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
8862050
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
10 Years
187848M4A Specifications
General Information
Type
Evaporator Coil
Product Line
AccuCharge
Refrigerant Type
R-410a
Casing
Uncased
Shape
A Coil
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Performance
Tonnage ? Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Nominal Cooling Capacity
48000 BTU
Dimensions
Liquid Connection Size
3/8 Inch
Gas Connection Size
7/8 Inch
Product Height
19 1/2 Inches
Product Width
18 Inches
Product Depth
19 5/8 Inches
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
922594 Specifications
General Information
Type
Coil Cabinet
Dimensions
Product Height
26 Inches
Product Width
19 3/4 Inches
Product Depth
23 3/4 Inches
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Revolv - 4.0 Ton Cooling - 72k BTU/Hr Heating - Air Conditioner + High Efficiency Furnace Kit - 14.0 SEER - 95% AFUE - For Downflow Installation
Revolv RSC1448RG772D
+
Reset View
Revolv RSC1448RG772D
Revolv RSC1448RG772D
Revolv RSC1448RG772D
Revolv RSC1448RG772D
Revolv RSC1448RG772D
Revolv RSC1448RG772D
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile