Peerless MI-04, Gas Fired, Hot water Boiler, Electronic Ignition, Taco 007 Pump, NG - 105,000 BTU
Model:
MI-04-SV-WPC-N
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- Up to 83.8% AFUE
- Honeywell SmartValve Intermittent Ignition or Standing Pilot
- Natural Chimney Draft Venting
- Enameled Steel Jacket Reduces Boiler Heat Loss
- Cast Iron Shell with Stainless Steel Push Nipples
- Built In Safety Controls
- Low Profile Design
- Fully Packaged and Ready to Install
- Parts Warranty: 1 year
- Heat Exchanger Warranty: Limited Lifetime
Peerless MI-04, Gas Fired, Hot water Boiler, Electronic Ignition, Taco 007 Pump, NG - 105,000 BTU
For homeowners with a small utility room or for those who need a boiler with a smaller footprint, Peerless' MI series gas fired boiler offers an excellent space saving option. This cast iron boiler comes fully packaged and ready to install measuring in at only 31 inches tall. Although small, the boiler is not short on power; its cast iron heat exchanger and solid construction lend themselves the higher capacity models achieving heat output of up to 211,000 BTU. The MI series boiler is a chimney vented boiler, and can achieve efficiencies of up to 83.8% AFUE. The boiler can be equipped with either a standing pilot burner or an intermittent ignition to suit the personal preferences of any homeowner.
Peerless MI-04-SV-WPC-N Gas Fired Hot Water Boiler Features:Specifications
MI-04-SV-WPC-N
Performance
Maximum Input Capacity
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
105000 BTU
DOE Heating Capacity
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
86000 BTU
Net I=B=R Capacity
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
75000 BTU
Efficiency
82.1 %
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Lifetime Years
General Information
Medium
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Primary Vent Pipe Diameter
5 Inches
Supply Connection
1 1/2 Inches
Return Connection
1 1/4 Inches
Product Height
31 3/8 Inches
Product Width
15 7/8 Inches
Product Depth
26 5/8 Inches
Product Weight
375 Pounds
Shipping Weight
375 Pounds
Reviews
Peerless MI-04-SV-WPC-N Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
How-To Articles
How to Pick the Perfect City Multi Outdoor Unit
When dealing with very large buildings with many different zones, choosing a hea...
On-Demand Furnace and AC Installation
eComfort Installation is the easiest, most-efficient way to get your home's air...
Smart, Safe, Clean Home Tips
Americans are spending more time at home than ever before. It’s very like...
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Peerless MI-04, Gas Fired, Hot water Boiler, Electronic Ignition, Taco 007 Pump, NG - 105,000 BTU
Customer Review Images