Noritz NRCP982 - 5.8 GPM at 60° F Rise - 0.94 UEF - Gas Tankless Water Heater - Direct Vent
Model: NRCP982-DV-NG
5.0 out of 55.0 out of 55.0 out of 55.0 out of 55.0 out of 5
Number of Reviews(6)
Write a Review
$1,199.00
Was $1,499.00
Closeout Item Icon
Closeout Item
Free Shipping
Learn More About Free Freight
Free Shipping
*This product qualifies for Free Shipping anywhere in the contiguous US. Accessories may ship separately. Items over 100lbs shipped via semi-truck, be sure to select "Lift Gate" to lower the product to the ground curbside. Remote area surcharges may apply, see our full shipping policy for more details.
Factory-Direct
Ships in 4-7 Business Days
Shipping to60601
Shipping Details
*We currently CANNOT ship this product to Canada or any destination outside of the United States

Share
  • Product Description
  • 6
    Reviews
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Fuel
Natural Gas
Location
Indoor
# of Showers
2.8
UEF
Fuel
Natural Gas
Location
Indoor
#of Showers
2.8
Uniform Energy Factor
0.94
Energy Star Rated
Yes
Features
Features
    Noritz has been in the business of providing homes with hot water for over sixty years, and introduced the industry’s first electronically controlled water heater in 1981. The NRCP982-DV-NG represents the culmination of the experience gained over those sixty years. These units are designed with a heavy duty stainless steel heat exchangers that allow for optimal performance and are backed by a 12-year heat exchanger warranty. The NRCP models include a built-in recirculation pump to protect your water heater from freezing and help deliver water to your fixtures more quickly.
  • Built-In Pump Included
  • The NRCP line includes a built-in recirculation pump to provide internal and external pre-heat recirculation. These heaters include a built-in display to program the recirculation system to operate when needed.
  • Built for Efficiency
  • The NRCP982-DV-NG boasts a Uniform Energy Factor of 0.94 and a direct electronic ignition that avoids always-on pilot light installations, saving you fuel and money.
  • Made with Safety in Mind
  • Noritz tankless water heaters have safety devices that protect your unit including a flame sensor, condensate overfill sensor, overheat prevention device, lightning and freeze protection devices, all backed by a five-year parts warranty.
  • Included Remote Controller and Power Cord
  • The Noritz NRCP982-DV-NG includes an easy-to-use, remote controller that allows for convenient, adjustable temperature control for your hot water system. These heaters also include 6' power cords, giving more installation flexibilty.
  • Compact, Modern Design
  • Noritz tankless water heaters are engineered to have a compact design that easily allows for indoor installation.
  • Multiple Unit System Compatibility
  • For extra-demanding systems, the Noritz NRCP982-DV-NG unit can be linked together with another unit for twice the hot water capacity.
  • Temperature Controls
  • Includes remote thermostat that can precisely adjust the output temperature from 100°F to 140°F with the capability to display temperatures in both Celsius and Fahrenheit
Specifications
General Information
Type
Tankless Water Heater
Product Line
ecoTough
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Stainless Steel
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Storage Type
Tankless
Mount Type
Wall
Installation Location
Indoor
Maximum Altitude
10000 Feet
Includes Pump
Yes
Gas Conversion Kit
Not Available
UPC
817000013042
Performance
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
180000 BTU
Minimum Input Capacity
18000 BTU
Flow Rate at 40F Temperature Rise Learn More
Flow Rate at 40F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
8.7 GPM
Flow Rate at 45F Temperature Rise Learn More
Flow Rate at 45F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
7.8 GPM
Flow Rate at 50F Temperature Rise Learn More
Flow Rate at 50F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
7.0 GPM
Flow Rate at 60F Temperature Rise Learn More
Flow Rate at 60F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
5.8 GPM
Flow Rate at 70F Temperature Rise Learn More
Flow Rate at 70F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
4.9 GPM
Uniform Energy Factor Learn More
Uniform Energy Factor
Uniform Energy Factor (UEF) is a measurement of water heater energy efficiency. The higher the energy factor, the more efficient the water heater.
0.94
Minimum Flow Rate
0.5 GPM
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/4 Inch
Cold Water Inlet
3/4 Inch
Hot Water Outlet
3/4 Inch
Product Height
28 17/24 Inches
Product Width
17 7/24 Inches
Product Depth
14 19/24 Inches
Product Weight
85 Pounds
Intake Diameter
3 Inches
Exhaust Diameter
3 Inches
Certifications
Energy Star Listed
Yes
AHRI Certified
Yes
UPC Listed
Yes
NSF Certified Learn More
NSF Certified
The National Sanitation Foundation has developed public health standards and certification programs to protect the world's food, water, consumer products and environment.
Yes
AHRI Reference Number
7432737
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
12 Years
Fuel
Natural Gas
Location
Indoor
# of Showers
2.8
UEF
Fuel
Natural Gas
Location
Indoor
#of Showers
2.8
Uniform Energy Factor
0.94
Energy Star Rated
Yes
Features
Features
    Noritz has been in the business of providing homes with hot water for over sixty years, and introduced the industry’s first electronically controlled water heater in 1981. The NRCP982-DV-NG represents the culmination of the experience gained over those sixty years. These units are designed with a heavy duty stainless steel heat exchangers that allow for optimal performance and are backed by a 12-year heat exchanger warranty. The NRCP models include a built-in recirculation pump to protect your water heater from freezing and help deliver water to your fixtures more quickly.
  • Built-In Pump Included
  • The NRCP line includes a built-in recirculation pump to provide internal and external pre-heat recirculation. These heaters include a built-in display to program the recirculation system to operate when needed.
  • Built for Efficiency
  • The NRCP982-DV-NG boasts a Uniform Energy Factor of 0.94 and a direct electronic ignition that avoids always-on pilot light installations, saving you fuel and money.
  • Made with Safety in Mind
  • Noritz tankless water heaters have safety devices that protect your unit including a flame sensor, condensate overfill sensor, overheat prevention device, lightning and freeze protection devices, all backed by a five-year parts warranty.
  • Included Remote Controller and Power Cord
  • The Noritz NRCP982-DV-NG includes an easy-to-use, remote controller that allows for convenient, adjustable temperature control for your hot water system. These heaters also include 6' power cords, giving more installation flexibilty.
  • Compact, Modern Design
  • Noritz tankless water heaters are engineered to have a compact design that easily allows for indoor installation.
  • Multiple Unit System Compatibility
  • For extra-demanding systems, the Noritz NRCP982-DV-NG unit can be linked together with another unit for twice the hot water capacity.
  • Temperature Controls
  • Includes remote thermostat that can precisely adjust the output temperature from 100°F to 140°F with the capability to display temperatures in both Celsius and Fahrenheit
Specifications
General Information
Type
Tankless Water Heater
Product Line
ecoTough
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Stainless Steel
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Storage Type
Tankless
Mount Type
Wall
Installation Location
Indoor
Maximum Altitude
10000 Feet
Includes Pump
Yes
Gas Conversion Kit
Not Available
UPC
817000013042
Performance
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
180000 BTU
Minimum Input Capacity
18000 BTU
Flow Rate at 40F Temperature Rise Learn More
Flow Rate at 40F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
8.7 GPM
Flow Rate at 45F Temperature Rise Learn More
Flow Rate at 45F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
7.8 GPM
Flow Rate at 50F Temperature Rise Learn More
Flow Rate at 50F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
7.0 GPM
Flow Rate at 60F Temperature Rise Learn More
Flow Rate at 60F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
5.8 GPM
Flow Rate at 70F Temperature Rise Learn More
Flow Rate at 70F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
4.9 GPM
Uniform Energy Factor Learn More
Uniform Energy Factor
Uniform Energy Factor (UEF) is a measurement of water heater energy efficiency. The higher the energy factor, the more efficient the water heater.
0.94
Minimum Flow Rate
0.5 GPM
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/4 Inch
Cold Water Inlet
3/4 Inch
Hot Water Outlet
3/4 Inch
Product Height
28 17/24 Inches
Product Width
17 7/24 Inches
Product Depth
14 19/24 Inches
Product Weight
85 Pounds
Intake Diameter
3 Inches
Exhaust Diameter
3 Inches
Certifications
Energy Star Listed
Yes
AHRI Certified
Yes
UPC Listed
Yes
NSF Certified Learn More
NSF Certified
The National Sanitation Foundation has developed public health standards and certification programs to protect the world's food, water, consumer products and environment.
Yes
AHRI Reference Number
7432737
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
12 Years
Product Specs
+
Specifications
General Information
Type
Tankless Water Heater
Product Line
ecoTough
Medium Learn More
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Stainless Steel
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type Learn More
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Condensing
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Storage Type
Tankless
Mount Type
Wall
Installation Location
Indoor
Maximum Altitude
10000 Feet
Includes Pump
Yes
Gas Conversion Kit
Not Available
UPC
817000013042
Performance
Maximum Input Capacity Learn More
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
180000 BTU
Minimum Input Capacity
18000 BTU
Flow Rate at 40F Temperature Rise Learn More
Flow Rate at 40F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
8.7 GPM
Flow Rate at 45F Temperature Rise Learn More
Flow Rate at 45F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
7.8 GPM
Flow Rate at 50F Temperature Rise Learn More
Flow Rate at 50F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
7.0 GPM
Flow Rate at 60F Temperature Rise Learn More
Flow Rate at 60F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
5.8 GPM
Flow Rate at 70F Temperature Rise Learn More
Flow Rate at 70F Temperature Rise
Flow rate measures how much hot water your heater can deliver. Click Learn More to determine the appropriate temperature rise to use based on your location. Learn More
4.9 GPM
Uniform Energy Factor Learn More
Uniform Energy Factor
Uniform Energy Factor (UEF) is a measurement of water heater energy efficiency. The higher the energy factor, the more efficient the water heater.
0.94
Minimum Flow Rate
0.5 GPM
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/4 Inch
Cold Water Inlet
3/4 Inch
Hot Water Outlet
3/4 Inch
Product Height
28 17/24 Inches
Product Width
17 7/24 Inches
Product Depth
14 19/24 Inches
Product Weight
85 Pounds
Intake Diameter
3 Inches
Exhaust Diameter
3 Inches
Certifications
Energy Star Listed
Yes
AHRI Certified
Yes
UPC Listed
Yes
NSF Certified Learn More
NSF Certified
The National Sanitation Foundation has developed public health standards and certification programs to protect the world's food, water, consumer products and environment.
Yes
AHRI Reference Number
7432737
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
12 Years
Reviews
(6)
+
Noritz NRCP982-DV-NG Reviews & Ratings
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
Media Gallery
Noritz NRCP982 - 5.8 GPM at 60° F Rise - 0.94 UEF - Gas Tankless Water Heater - Direct Vent
Noritz NRCP982-DV-NG
+
Reset View
Noritz NRCP982-DV-NG
Noritz NRCP982-DV-NG
Noritz NRCP982-DV-NG
×
Customer Review Images