Welcome:  Sign In | Contact Us
Call Us: (866)-437-7998

Modine POR - 145,000 BTU - Unit Heater - Oil - 80% AFUE - Chimney Vented - Aluminized Steel Heat Exchanger - Propeller Driven

Modine POR - 145,000 BTU - Unit Heater - Oil - 80% AFUE - Chimney Vented - Aluminized Steel Heat Exchanger - Propeller Driven
Our Price
Compare Prices
Shipping Info
Model: POR145B0101
$4,342.00
Ships in 2-3 Weeks
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Input Capacity (BTU/h)
Add-Ons
 
Ships in 2-3 Weeks
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to California or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    The Modine POR145 is an advanced oil fired unit heater that is both efficient and reliable. Capable of emitting 145,000 BTU/hr of heat, the POR145 has enough power to warm even very large areas. An efficient PSC fan motor powers the propeller while a two stage fuel unit ensures fuel pressure is always kept high. The unit heater uses advanced microprocessor based burner technology to provide an all-in-one tool for data readings, efficient fuel consumption, and automatic reset control.
  • Advanced Flame Retention Burner
  • The flame retention burner on the POR145 produces a highly stable flame, giving the burner a 20 to 30 percent increase in combustion efficiency over non-flame retention burners.
  • Two Stage Fuel Delivery
  • The fuel unit on the POR145 uses two distinct stages to ensure maximum fuel pressure during varying degrees of operation. This allows the unit heater a high degree of functionality even in high lift applications.
  • Permanent Capacitor Split Motor
  • The permanent capacitor split motor design used for the propeller's motor works together with high grade ball bearings to reduce motor energy consumption and maintenance needs.
  • Interrupted-Duty Ignition
  • The sensors included in the ignition disable the igniter once a flame has been detected. This feature extends the life of the ignition system, reduces component noise, and reduces gas usage during the ignition process to an absolute minimum.
  • Beckett CleanCut Oil Pump
  • The POR145 comes with a Beckett CleanCut pump. The cleaning operation of the burner cuts oil flow almost immediately after power to the motor is cut, resulting is less wasted oil and higher system life.
  • Modine Installation
  • Installation by a professional installer is required by the manufacturer.
Specifications
General Information
Product Line
POR
Heat Exchanger Material
Aluminized Steel
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Oil
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Horizontal
Performance
Heating Capacity
116000 BTU
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
145000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Maximum Air Flow
2400 CFM
Air Throw
50 Feet
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
8 Inches
Product Height
35 1/4 Inches
Product Width
27 1/2 Inches
Product Depth
38 1/8 Inches
Shipping Weight
333 Pounds
Certifications
Country of Origin
United States
UL Listed
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Features
Features
    The Modine POR145 is an advanced oil fired unit heater that is both efficient and reliable. Capable of emitting 145,000 BTU/hr of heat, the POR145 has enough power to warm even very large areas. An efficient PSC fan motor powers the propeller while a two stage fuel unit ensures fuel pressure is always kept high. The unit heater uses advanced microprocessor based burner technology to provide an all-in-one tool for data readings, efficient fuel consumption, and automatic reset control.
  • Advanced Flame Retention Burner
  • The flame retention burner on the POR145 produces a highly stable flame, giving the burner a 20 to 30 percent increase in combustion efficiency over non-flame retention burners.
  • Two Stage Fuel Delivery
  • The fuel unit on the POR145 uses two distinct stages to ensure maximum fuel pressure during varying degrees of operation. This allows the unit heater a high degree of functionality even in high lift applications.
  • Permanent Capacitor Split Motor
  • The permanent capacitor split motor design used for the propeller's motor works together with high grade ball bearings to reduce motor energy consumption and maintenance needs.
  • Interrupted-Duty Ignition
  • The sensors included in the ignition disable the igniter once a flame has been detected. This feature extends the life of the ignition system, reduces component noise, and reduces gas usage during the ignition process to an absolute minimum.
  • Beckett CleanCut Oil Pump
  • The POR145 comes with a Beckett CleanCut pump. The cleaning operation of the burner cuts oil flow almost immediately after power to the motor is cut, resulting is less wasted oil and higher system life.
  • Modine Installation
  • Installation by a professional installer is required by the manufacturer.
Specifications
General Information
Product Line
POR
Heat Exchanger Material
Aluminized Steel
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Oil
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Horizontal
Performance
Heating Capacity
116000 BTU
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
145000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Maximum Air Flow
2400 CFM
Air Throw
50 Feet
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
8 Inches
Product Height
35 1/4 Inches
Product Width
27 1/2 Inches
Product Depth
38 1/8 Inches
Shipping Weight
333 Pounds
Certifications
Country of Origin
United States
UL Listed
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Product Specs
+
Specifications
General Information
Product Line
POR
Heat Exchanger Material
Aluminized Steel
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Oil
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Horizontal
Performance
Heating Capacity
116000 BTU
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
145000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Maximum Air Flow
2400 CFM
Air Throw
50 Feet
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
8 Inches
Product Height
35 1/4 Inches
Product Width
27 1/2 Inches
Product Depth
38 1/8 Inches
Shipping Weight
333 Pounds
Certifications
Country of Origin
United States
UL Listed
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Modine POR - 145,000 BTU - Unit Heater - Oil - 80% AFUE - Chimney Vented - Aluminized Steel Heat Exchanger - Propeller Driven
Modine POR145B0101
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile