Answer:This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson Supply location near you.
How Do I Update My Pickup Location?
Answer:The nearest pickup location within a 50-mile radius is automatically chosen when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
How Do I Place a Local Pickup Order?
Answer:Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
When Can Items Be Picked Up?
Answer:Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Orders that have not been picked up within two business days may be cancelled. You should opt to have your items shipped if you are not able to pick them up promptly.
Who Can Pick Up My Order?
Answer:You will be prompted to enter the name, mobile phone, and email address of the person who will be picking up the order during checkout. We will use this information to ensure the order is picked up by an authorized individual.
Why Can't I Select Local Pickup for Some Items?
Answer:Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Why Can't I Select Shipping for Some Items?
Answer:Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Which Payment Methods Are Accepted?
Answer:Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Hover to zoom
1 Of 5
+10
View All
Mitsubishi - 6k BTU Cooling + Heating - M-Series H2i Wall Mounted Air Conditioning System - 33.1 SEER
Expert Recommended AccessoriesSelected by Ken, our Expert
Required Accessories9
These accessories are required to properly setup/install this product.
Optional Accessories10
Features
For over 50 years, Mitsubishi has remained at the forefront of the mini split industry thanks to their dedication to providing efficient, user-friendly comfort solutions. Part of Mitsubishi's hyper-heating product line, the MZ-FH06NA is a packaged single zone heat pump mini split system designed to bring high-efficiency zoned comfort to homes in frigid climates. The wall mounted indoor unit, MSZ-FH06NA, boasts a functional design, and operates at volumes as low as 20 dB. Thanks to the included mounting plate, it is easy to install on nearly any wall. The outdoor condenser uses some of the most advanced technology available to modulate temperature without the energy-wasting overshoots and short-cycling associated with simpler systems. With an included wireless remote controller, this system is the perfect combination of convenience and comfort for any application in a sub-freezing environment.
Precision Temperature Control Technology
The MUZ-FH06NA condenser is equipped with inverter technology and an electronic linear expansion valve. By adjusting compressor speed and refrigerant flow, the unit matches output to the zone for precise temperature control and improved efficiency.
i-see Sensor 3D
The sensor monitors the floor and ceiling of its zone for occupancy and fluctuations in temperature. If it detects an underserved area, the unit will temporarily adjust airflow. If it doesn't find human heat signatures, it will enter energy saving mode.
H2i Technology
Low or negative ambient temperatures don't bother the MUZ-FH06NA. It is rated for 100% heating capacity at 5 degrees F and continues to provide heating in outdoor conditions as low as -13 degrees F.
Advanced Filtration System
A catalyst-coated filter is the first defense against odors. A second deodorizing filter utilizes a ceramic surface element and platinum nanoparticles to absorb smells. An enzyme-based anti-allergy filter captures and destroys bacteria and particulates.
Hot-Start
Mitsubishi's hot start technology prevents cold drafts by delaying fan operation until the heat exchanger has warmed up.
Smart Set
Smart Set allows you to save cooling and heating profiles, each consisting of a temperature, a fan speed, and an airflow direction. These profiles can be activated easily with a single press of the Smart Set button on the remote controller.
Powerful Mode
The powerful setting on the MSZ-FH06NA makes it easy to get your zone to the perfect temperature quickly. When it is activated, the unit temporarily increases refrigerant flow and fan speed to provide quick comfort through rapid heating or cooling.
Econo Cool Mode
By slowly adjusting the cooling set point and swinging the horizontal vanes, the MSZ-FH06NA can improve the efficiency of cooling operations without compromising the comfort provided.
Dehumidification
When the indoor unit is run in dry mode, the coil's temperature stays just below the dew point of the return air, removing unwanted moisture. This improves comfort and reduces the chance of mold growth and other property damage in the conditioned space.
Multiple Vane Control Options
Auto mode selects the best vane position based on operating mode, and the swing modes cycle through all positions for maximum coverage. When wide mode is activated, fan speed increases beyond the current setting.
Product Includes
(1) Mitsubishi - 6k BTU - FH-Series H2i Outdoor Condenser - Single Zone Only (MUZ-FH06NA)
(1) Mitsubishi FH-Series 6k BTU Wall Mounted Unit - For Multi or Single-Zone (MSZ-FH06NA)
Product Note
This product requires the following accessories for installation:
Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
Connecting Wire - This durable, insulated wire provides power to your indoor unit from your outdoor condenser.
Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
Adding these accessories to your order will provide a complete, ready-to-install mini split system.
eComfort.com Note
If you will be using your mini split in conditions where ambient temperatures are expected to be (1) below 32 degrees F for more than 72 continuous hours or (2) below 0 degrees F for more than 24 continuous hours, we advise the use of a drain pan heater to prevent your mini split from halting function due to icing. You can find the appropriate drain pan heater in the accessories tab above.All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
Product Includes
(1) Mitsubishi - 6k BTU - FH-Series H2i Outdoor Condenser - Single Zone Only (MUZ-FH06NA)
(1) Mitsubishi FH-Series 6k BTU Wall Mounted Unit - For Multi or Single-Zone (MSZ-FH06NA)
MZ-FH06NA
General Information
Type
Wall Mounted
Product Line
M-Series H2i
Product Sub-line
Hyper-Heating
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Number of ZonesA zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Indoor Unit Size(s)Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7
Outdoor Unit Size
6000 BTU
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
6000
Cooling Capacity
6000 BTU
Heating Capacity
8700 BTU
SEER SEERSEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
33.1
HSPF HSPFHSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
13.5
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
1
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
6000
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
48 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-13 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Maximum Line Length
65 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 5/8 Inches
Product Width
31 1/2 Inches
Product Depth
11 1/4 Inches
Product Weight
81 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Remote Control
Wireless
Indoor Unit Size(s) Indoor Unit Size(s)Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
6
Installation Location
Indoor
Performance
Cooling BTU
6000
Cooling Capacity
6000 BTU
Maximum Air Flow
381 CFM
Minimum Air Flow
137 CFM
Minimum Sound Level
20 dB
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
42 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
12 11/16 Inches
Product Width
36 7/16 Inches
Product Depth
9 3/16 Inches
Product Weight
29 Pounds
Shipping Weight
36 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Reviews
(45)
Mitsubishi MZ-FH06NA Reviews & Ratings
Customer Photos and Videos
How-To Articles
How to Pick the Perfect Mini Split Wall Mounted Indoor Unit
Wall-mounted units are the most commonly found, most affordable option for indo...