Hover to zoom
1 Of 5
LG Wall Mounted 2-Zone System - 30,000 BTU Outdoor - 12k + 18k Indoor - 19.7 SEER
Model: L2H30W12180000-B
+
Share This Product
-
Product Description
-
9Reviews
-
1Product Q&A
-
Recommended Accessories
-
How-To Articles
-
Manuals
Product Description
+−
Features
Features
- Inverter Technology
- LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
- Gold Fin Protection
- To ensure the reliability and longevity of the LMU30CHV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
- Low Ambient Operations
- This outdoor unit supports Cooling operations down to 14 degrees Fahrenheit and heating operations down to -4 degrees Fahrenheit. There is also a defrost feature, which removes frost from the condenser coil in frigid conditions.
- Quiet Design
- Thanks to brushless fan motors, both the outdoor and indoor units in this system produce less mechanical and electrical noise. The indoor units feature a cross flow fan design that further reduces noise by restricting the surface pressure of airflow.
- Air Flow Options
- These LG units give you two options for automating air flow. In swing mode, a unit will rotate through all four air flow directions. Chaos Wind mode cycles both air flow direction and fan speed to provide a natural circulation pattern.
- Self-Cleaning Coil
- These wall mounted indoor units feature self-cleaning heat exchanger coils that automatically remove dirt and moisture. This helps to prevent unpleasant odors and to combat the formation of mold.
- Built in Wi-Fi
- With built in Wi-Fi, you have the ability to control your LG air conditioner with smart enabled devices. Simply download the SmartThinQ® app on your smart device to get started.
- Dehumidify
- LG's mini split indoor units include a dehumidifying operation mode. In this mode, the unit's internal sensors monitor temperature and modify the set point and fan speed to remove moisture from the air.
- Recommended line set sizes for indoor unit connectivity:
- LSN120HSV5: 1/4" x 3/8" Line Set
- LSN180HSV5: 1/4" x 1/2" Line Set
- (1) LG - 30k BTU - Outdoor Condenser - For 2-4 Zones (LMU30CHV)
- (1) LG 18k BTU Wall Mounted Unit - For Multi or Single-Zone (LSN180HSV5)
- (1) LG 12k BTU Wall Mounted Unit - For Multi or Single-Zone (LSN120HSV5)
- Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
- Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
- Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
- Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
- Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
- Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
The LG Ductless Dual Zone Heat Pump System is a convenient solution that is cost-effective, quiet, and attractive. The LG LSN120HSV5 and LSN180HSV5 wall-mounted heat pump air handlers are slim, lightweight, and aesthetically pleasing units. Also each LG indoor heat pump unit comes with its own remote control, allowing you to set the temperature individually in different rooms. The LG LSN120HSV5 and LSN180HSV5 heat pump air handler units are connected to the LG LMU30CHV heat pump exterior unit. The LG interior units are available in a variety of styles, including Art Cool, Standard, Ceiling Cassette, and Ceiling Concealed Duct models.
Product Includes
Product Note
Each indoor unit will include any port adapters necessary for multi-zone installation.This product requires the following accessories for installation:
LG products include a 10-year warranty with the requirement that installation is completed by a licensed contractor and that the product is registered at https://lg-dfs-warranty.com/ within 60 days of installation.
All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
LG products include a 10-year warranty with the requirement that installation is completed by a licensed contractor and that the product is registered at https://lg-dfs-warranty.com/ within 60 days of installation.
All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
General Information
Type
Wall Mounted
Product Line
Multi F
Product Sub-line
Standard
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12 + 18
Outdoor Unit Size
30000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
22.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
13.0
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.0
Cooling Power Input
2585 Watts
Heating Power Input
2666 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
188 Pounds
Shipping Weight
192 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
8111325
LMU30CHV Specifications+
LSN180HSV5 Specifications+
LSN120HSV5 Specifications+
Features
Features
- Inverter Technology
- LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
- Gold Fin Protection
- To ensure the reliability and longevity of the LMU30CHV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
- Low Ambient Operations
- This outdoor unit supports Cooling operations down to 14 degrees Fahrenheit and heating operations down to -4 degrees Fahrenheit. There is also a defrost feature, which removes frost from the condenser coil in frigid conditions.
- Quiet Design
- Thanks to brushless fan motors, both the outdoor and indoor units in this system produce less mechanical and electrical noise. The indoor units feature a cross flow fan design that further reduces noise by restricting the surface pressure of airflow.
- Air Flow Options
- These LG units give you two options for automating air flow. In swing mode, a unit will rotate through all four air flow directions. Chaos Wind mode cycles both air flow direction and fan speed to provide a natural circulation pattern.
- Self-Cleaning Coil
- These wall mounted indoor units feature self-cleaning heat exchanger coils that automatically remove dirt and moisture. This helps to prevent unpleasant odors and to combat the formation of mold.
- Built in Wi-Fi
- With built in Wi-Fi, you have the ability to control your LG air conditioner with smart enabled devices. Simply download the SmartThinQ® app on your smart device to get started.
- Dehumidify
- LG's mini split indoor units include a dehumidifying operation mode. In this mode, the unit's internal sensors monitor temperature and modify the set point and fan speed to remove moisture from the air.
- Recommended line set sizes for indoor unit connectivity:
- LSN120HSV5: 1/4" x 3/8" Line Set
- LSN180HSV5: 1/4" x 1/2" Line Set
- (1) LG - 30k BTU - Outdoor Condenser - For 2-4 Zones (LMU30CHV)
- (1) LG 18k BTU Wall Mounted Unit - For Multi or Single-Zone (LSN180HSV5)
- (1) LG 12k BTU Wall Mounted Unit - For Multi or Single-Zone (LSN120HSV5)
- Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
- Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
- Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
- Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
- Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
- Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
The LG Ductless Dual Zone Heat Pump System is a convenient solution that is cost-effective, quiet, and attractive. The LG LSN120HSV5 and LSN180HSV5 wall-mounted heat pump air handlers are slim, lightweight, and aesthetically pleasing units. Also each LG indoor heat pump unit comes with its own remote control, allowing you to set the temperature individually in different rooms. The LG LSN120HSV5 and LSN180HSV5 heat pump air handler units are connected to the LG LMU30CHV heat pump exterior unit. The LG interior units are available in a variety of styles, including Art Cool, Standard, Ceiling Cassette, and Ceiling Concealed Duct models.
Product Includes
Product Note
Each indoor unit will include any port adapters necessary for multi-zone installation.This product requires the following accessories for installation:
LG products include a 10-year warranty with the requirement that installation is completed by a licensed contractor and that the product is registered at https://lg-dfs-warranty.com/ within 60 days of installation.
All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
LG products include a 10-year warranty with the requirement that installation is completed by a licensed contractor and that the product is registered at https://lg-dfs-warranty.com/ within 60 days of installation.
All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
General Information
Type
Wall Mounted
Product Line
Multi F
Product Sub-line
Standard
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12 + 18
Outdoor Unit Size
30000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
22.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
13.0
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.0
Cooling Power Input
2585 Watts
Heating Power Input
2666 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
188 Pounds
Shipping Weight
192 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
8111325
LMU30CHV Specifications+
LSN180HSV5 Specifications+
LSN120HSV5 Specifications+
Product Specs
+−
Specifications
General Information
Type
Wall Mounted
Product Line
Multi F
Product Sub-line
Standard
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12 + 18
Outdoor Unit Size
30000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
22.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
13.0
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
10.0
Cooling Power Input
2585 Watts
Heating Power Input
2666 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
188 Pounds
Shipping Weight
192 Pounds
Certifications
ETL Listed
Yes
UL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
8111325
LMU30CHV Specifications+
LSN180HSV5 Specifications+
LSN120HSV5 Specifications+
Product Q&A
(1)
+−

Search Product Q&A's
Answered by Chris, the eComfort Product Expert
+−
Can the LG system deliver heat down to 5 degrees? If so, are the BTU ratings listed the same at this temp?
Andrew S.
from Massachusetts
July 24, 2016
Answer
LG outdoor units do not shut down based on outdoor temperature*. They will deliver heat at 5 degrees, and lower. However, their output will decrease as temperature drops toward freezing and below. For specific details on capacities at different outdoor temperatures, you can reference the Engineering Manual. If you need any help interpreting the manual, feel free to email or call us.
*The units will shut down if operating pressures in the systems are unsafe. Once pressures return to safe levels, the units will resume operation.
*The units will shut down if operating pressures in the systems are unsafe. Once pressures return to safe levels, the units will resume operation.
Was this answer helpful?
Yes

15
No

0
Recommended Accessories
+−

Expert Recommended Accessories
Hand Picked By Our Expert Chris
Required Accessories
Add All Required
Optional Accessories
How-To Articles
+−
By Chris Z.
Manuals
+−
+
Ask Chris, Our Product Expert, A Question!
*Required Fields

+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.

Media Gallery
LG Wall Mounted 2-Zone System - 30,000 BTU Outdoor - 12k + 18k Indoor - 19.7 SEER








×
Customer Review Images