LG Concealed Duct 2-Zone System - 30,000 BTU Outdoor - 12k + 18k Indoor - 15.4 SEER

LG Concealed Duct 2-Zone System - 30,000 BTU Outdoor - 12k + 18k Indoor - 15.4 SEER
Our Price
Compare Prices
Shipping Info
Model: L2H30D12180000-A
(Based on expert analysis, manufacturer ratings and customer reviews)
5.0 out of 55.0 out of 55.0 out of 55.0 out of 55.0 out of 5
Number of Reviews (3)
Write A Review
$3,337.00
$3,170.15
Ships in 2-5 Business Days
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Outdoor Unit BTU/h
Indoor Unit Sizes ? Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (9k + 12k) means the system includes a 9k BTU unit and a 12k BTU unit.
High Heating Capacity
Add-Ons
 
Ships in 2-5 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • 3
    Reviews
  • 1
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    LG's devotion to providing efficient ductless solutions can be seen across the Multi F line. This concealed duct ductless heat pump system pairs a powerful LMU30CHV outdoor condenser with two concealed duct indoor units. These units are designed for installation in short-run ducting with low static pressures. With this system, you can add quiet zoned comfort to your home without mounting anything on your walls. Like a central system, small air registers are all that your guests will see with this concealed duct heat pump system.
  • Inverter Technology
  • LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
  • Gold Fin Protection
  • To ensure the reliability and longevity of the LMU30CHV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
  • Low Ambient Operations
  • This outdoor unit supports cooling operations down to 14 degrees Fahrenheit and heating operations down to -4 degrees Fahrenheit. There is also a defrost feature, which removes frost from the condenser coil in frigid conditions.
  • Quiet Design
  • Thanks to brushless fan motors, both the outdoor and indoor units in this system produce less mechanical and electrical noise. A twin rotary compressor in the outdoor unit also limits vibration noise.
  • Automated Operation
  • Auto operation mode continually compares your zones' current and desired temperatures and uses that data to intelligently adjust fan speed and refrigerant flow to provide optimal comfort.
  • Sleep Mode
  • With the sleep mode and timer functions, you can set the indoor units to save energy at night. Sleep mode will incrementally adjust temperatures for an hour before the timer function automatically deactivates the units.
  • Recommended line set sizes for indoor unit connectivity:
  • LDN127HV4: 1/4" x 3/8" Line Set
  • LMDN186HV: 1/4" x 1/2" Line Set
  • Product Includes
    • (1) LG - 30k BTU - Outdoor Condenser - For 2-4 Zones (LMU30CHV)
    • (1) LG - 18k BTU - Low Static Concealed Duct Unit - For Multi-Zone (LMDN186HV)
    • (1) LG - 12k BTU - Low Static Concealed Duct Unit - For Multi or Single-Zone (LDN127HV4)
    • (2) LG - Simple Remote Controller - Wired (PREMTC00U)
    • (2) LG Wired Remote Control Extension Cable - 32 Feet (PZCWRC1)
    Product Note
    Each indoor unit will include any port adapters necessary for multi-zone installation.This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing. We recommend locally purchased PVC hard pipe for the condensate drain on cassette and concealed duct units.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system
Specifications
General Information
Type
Concealed Duct
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Number of Zones ? A zone is a room or area within a building that has its own temperature control.
2
Indoor Unit Size(s) ? Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (09 + 12) means the system includes a 9k BTU unit and a 12k BTU unit.
12 + 18
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
26030 BTU
Heating Capacity
29700 BTU
SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
15.4
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
9.3
HSPF ? HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
8.2
Cooling Power Input
2788 Watts
Heating Power Input
2987 Watts
Minimum Outdoor Temperature for Heating ? This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
239 Pounds
Shipping Weight
262 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
8111326
LMU30CHV Specifications
General Information
Type
Outdoor Condenser
Product Line
Multi F
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Maximum Number of Zones
4
Multi-Zone Compatible
Yes
Installation Location
Outdoor
Performance
Nominal Capacity
30000 BTU
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
55 dB
Minimum Outdoor Temperature for Heating ? This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
25 Amps
Dimensions
Maximum Line Length
246.1 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Line Set D Liquid Connection
1/4 Inch
Line Set D Gas Connection
3/8 Inch
Product Height
32 41/48 Inches
Product Width
37 10/24 Inches
Product Depth
15 1/2 Inches
Product Weight
137 Pounds
Shipping Weight
148 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
LMDN186HV Specifications
General Information
Type
Concealed Duct Unit
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
Yes
Installation Location
Indoor
Performance
Nominal Capacity
18000 BTU
Minimum Air Flow
353 CFM
Maximum Air Flow
530 CFM
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
36 dB
Minimum Sound Level
31 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
1/4 Inch
Gas Connection Size
1/2 Inch
Product Height
7 23/48 Inches
Product Width
35 7/16 Inches
Product Depth
27 9/16 Inches
Product Weight
51 Pounds
Shipping Weight
57 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
LDN127HV4 Specifications
General Information
Type
Concealed Duct Unit
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
Yes
Installation Location
Indoor
Performance
Nominal Capacity
12000 BTU
Minimum Air Flow
247 CFM
Maximum Air Flow
353 CFM
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
31 dB
Minimum Sound Level
27 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
1/4 Inch
Gas Connection Size
3/8 Inch
Product Height
7 23/48 Inches
Product Width
38 17/48 Inches
Product Depth
27 9/16 Inches
Product Weight
51 Pounds
Shipping Weight
60 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
PREMTC00U Specifications
General Information
Type
Wired Remote
Maximum Number of Zones
16
Power Source
Hard-Wired
Dimensions
Product Height
4 3/4 Inches
Product Width
5/8 Inch
Product Length
2 3/4 Inches
Product Weight
0.18 Pounds
PZCWRC1 Specifications
General Information
Type
Wire Kit
Dimensions
Product Length
33 Feet
Product Weight
0.25 Pounds
Certifications
Country of Origin
Korea
Features
Features
    LG's devotion to providing efficient ductless solutions can be seen across the Multi F line. This concealed duct ductless heat pump system pairs a powerful LMU30CHV outdoor condenser with two concealed duct indoor units. These units are designed for installation in short-run ducting with low static pressures. With this system, you can add quiet zoned comfort to your home without mounting anything on your walls. Like a central system, small air registers are all that your guests will see with this concealed duct heat pump system.
  • Inverter Technology
  • LG's outdoor condensers are designed with efficient inverter technology. An electronic expansion valve and a variable speed compressor carefully regulate the refrigerant flow, reducing energy consumption and allowing for consistent, accurate temperatures.
  • Gold Fin Protection
  • To ensure the reliability and longevity of the LMU30CHV's heat exchanger, LG employs a Gold Fin coating that prevents corrosion and improves durability.
  • Low Ambient Operations
  • This outdoor unit supports cooling operations down to 14 degrees Fahrenheit and heating operations down to -4 degrees Fahrenheit. There is also a defrost feature, which removes frost from the condenser coil in frigid conditions.
  • Quiet Design
  • Thanks to brushless fan motors, both the outdoor and indoor units in this system produce less mechanical and electrical noise. A twin rotary compressor in the outdoor unit also limits vibration noise.
  • Automated Operation
  • Auto operation mode continually compares your zones' current and desired temperatures and uses that data to intelligently adjust fan speed and refrigerant flow to provide optimal comfort.
  • Sleep Mode
  • With the sleep mode and timer functions, you can set the indoor units to save energy at night. Sleep mode will incrementally adjust temperatures for an hour before the timer function automatically deactivates the units.
  • Recommended line set sizes for indoor unit connectivity:
  • LDN127HV4: 1/4" x 3/8" Line Set
  • LMDN186HV: 1/4" x 1/2" Line Set
  • Product Includes
    • (1) LG - 30k BTU - Outdoor Condenser - For 2-4 Zones (LMU30CHV)
    • (1) LG - 18k BTU - Low Static Concealed Duct Unit - For Multi-Zone (LMDN186HV)
    • (1) LG - 12k BTU - Low Static Concealed Duct Unit - For Multi or Single-Zone (LDN127HV4)
    • (2) LG - Simple Remote Controller - Wired (PREMTC00U)
    • (2) LG Wired Remote Control Extension Cable - 32 Feet (PZCWRC1)
    Product Note
    Each indoor unit will include any port adapters necessary for multi-zone installation.This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing. We recommend locally purchased PVC hard pipe for the condensate drain on cassette and concealed duct units.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system
Specifications
General Information
Type
Concealed Duct
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Number of Zones ? A zone is a room or area within a building that has its own temperature control.
2
Indoor Unit Size(s) ? Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (09 + 12) means the system includes a 9k BTU unit and a 12k BTU unit.
12 + 18
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
26030 BTU
Heating Capacity
29700 BTU
SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
15.4
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
9.3
HSPF ? HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
8.2
Cooling Power Input
2788 Watts
Heating Power Input
2987 Watts
Minimum Outdoor Temperature for Heating ? This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
239 Pounds
Shipping Weight
262 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
8111326
LMU30CHV Specifications
General Information
Type
Outdoor Condenser
Product Line
Multi F
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Maximum Number of Zones
4
Multi-Zone Compatible
Yes
Installation Location
Outdoor
Performance
Nominal Capacity
30000 BTU
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
55 dB
Minimum Outdoor Temperature for Heating ? This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
25 Amps
Dimensions
Maximum Line Length
246.1 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Line Set D Liquid Connection
1/4 Inch
Line Set D Gas Connection
3/8 Inch
Product Height
32 41/48 Inches
Product Width
37 10/24 Inches
Product Depth
15 1/2 Inches
Product Weight
137 Pounds
Shipping Weight
148 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
LMDN186HV Specifications
General Information
Type
Concealed Duct Unit
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
Yes
Installation Location
Indoor
Performance
Nominal Capacity
18000 BTU
Minimum Air Flow
353 CFM
Maximum Air Flow
530 CFM
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
36 dB
Minimum Sound Level
31 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
1/4 Inch
Gas Connection Size
1/2 Inch
Product Height
7 23/48 Inches
Product Width
35 7/16 Inches
Product Depth
27 9/16 Inches
Product Weight
51 Pounds
Shipping Weight
57 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
LDN127HV4 Specifications
General Information
Type
Concealed Duct Unit
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
Yes
Installation Location
Indoor
Performance
Nominal Capacity
12000 BTU
Minimum Air Flow
247 CFM
Maximum Air Flow
353 CFM
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
31 dB
Minimum Sound Level
27 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
1/4 Inch
Gas Connection Size
3/8 Inch
Product Height
7 23/48 Inches
Product Width
38 17/48 Inches
Product Depth
27 9/16 Inches
Product Weight
51 Pounds
Shipping Weight
60 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
PREMTC00U Specifications
General Information
Type
Wired Remote
Maximum Number of Zones
16
Power Source
Hard-Wired
Dimensions
Product Height
4 3/4 Inches
Product Width
5/8 Inch
Product Length
2 3/4 Inches
Product Weight
0.18 Pounds
PZCWRC1 Specifications
General Information
Type
Wire Kit
Dimensions
Product Length
33 Feet
Product Weight
0.25 Pounds
Certifications
Country of Origin
Korea
Product Specs
+
Specifications
General Information
Type
Concealed Duct
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Number of Zones ? A zone is a room or area within a building that has its own temperature control.
2
Indoor Unit Size(s) ? Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. For example (09 + 12) means the system includes a 9k BTU unit and a 12k BTU unit.
12 + 18
DOE Regional Compliance ? In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
26030 BTU
Heating Capacity
29700 BTU
SEER ? SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
15.4
EER ? EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
9.3
HSPF ? HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
8.2
Cooling Power Input
2788 Watts
Heating Power Input
2987 Watts
Minimum Outdoor Temperature for Heating ? This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
239 Pounds
Shipping Weight
262 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
8111326
LMU30CHV Specifications
General Information
Type
Outdoor Condenser
Product Line
Multi F
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Maximum Number of Zones
4
Multi-Zone Compatible
Yes
Installation Location
Outdoor
Performance
Nominal Capacity
30000 BTU
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
55 dB
Minimum Outdoor Temperature for Heating ? This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
25 Amps
Dimensions
Maximum Line Length
246.1 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Line Set D Liquid Connection
1/4 Inch
Line Set D Gas Connection
3/8 Inch
Product Height
32 41/48 Inches
Product Width
37 10/24 Inches
Product Depth
15 1/2 Inches
Product Weight
137 Pounds
Shipping Weight
148 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
LMDN186HV Specifications
General Information
Type
Concealed Duct Unit
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
Yes
Installation Location
Indoor
Performance
Nominal Capacity
18000 BTU
Minimum Air Flow
353 CFM
Maximum Air Flow
530 CFM
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
36 dB
Minimum Sound Level
31 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
1/4 Inch
Gas Connection Size
1/2 Inch
Product Height
7 23/48 Inches
Product Width
35 7/16 Inches
Product Depth
27 9/16 Inches
Product Weight
51 Pounds
Shipping Weight
57 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
LDN127HV4 Specifications
General Information
Type
Concealed Duct Unit
Product Line
Multi F
Product Sub-line
Low-Static Ducted
Operating Mode ? Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling + Heating
Multi-Zone Compatible
Yes
Installation Location
Indoor
Performance
Nominal Capacity
12000 BTU
Minimum Air Flow
247 CFM
Maximum Air Flow
353 CFM
Maximum Sound Level ? Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
31 dB
Minimum Sound Level
27 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Dimensions
Liquid Connection Size
1/4 Inch
Gas Connection Size
3/8 Inch
Product Height
7 23/48 Inches
Product Width
38 17/48 Inches
Product Depth
27 9/16 Inches
Product Weight
51 Pounds
Shipping Weight
60 Pounds
Certifications
UL Listed
Yes
ETL Listed
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
PREMTC00U Specifications
General Information
Type
Wired Remote
Maximum Number of Zones
16
Power Source
Hard-Wired
Dimensions
Product Height
4 3/4 Inches
Product Width
5/8 Inch
Product Length
2 3/4 Inches
Product Weight
0.18 Pounds
PZCWRC1 Specifications
General Information
Type
Wire Kit
Dimensions
Product Length
33 Feet
Product Weight
0.25 Pounds
Certifications
Country of Origin
Korea
Reviews
(3)
+
LG L2H30D12180000-A Reviews & Ratings
Product Q&A
(1)
+
Search Product Q&A's Answered by Chris, the eComfort Product Expert
icon-social-fb1
+
Can the LG system deliver heat down to 5 degrees? If so, are the BTU ratings listed the same at this temp?
Andrew S. 
from Massachusetts 
July 24, 2016
Answer
LG outdoor units do not shut down based on outdoor temperature*. They will deliver heat at 5 degrees, and lower. However, their output will decrease as temperature drops toward freezing and below. For specific details on capacities at different outdoor temperatures, you can reference the Engineering Manual. If you need any help interpreting the manual, feel free to email or call us.

*The units will shut down if operating pressures in the systems are unsafe. Once pressures return to safe levels, the units will resume operation.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
LG Concealed Duct 2-Zone System - 30,000 BTU Outdoor - 12k + 18k Indoor - 15.4 SEER
LG L2H30D12180000-A
+
Reset View
LG L2H30D12180000-A
LG L2H30D12180000-A
LG L2H30D12180000-A
LG L2H30D12180000-A
LG L2H30D12180000-A
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile