MENU
/
Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Goodman GMEC96 - 120,000 BTU - Gas-Fired Furnace - NG - 96% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed

Goodman GMEC96 - 120,000 BTU - Gas-Fired Furnace - NG - 96% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed
Model: GMEC961205DN
$1,401.00
Only 4 In-Stock
Ships Monday, Jan 22nd
Free Shipping & 
Tax-Free (Except IL)
Free Lift Gate Service - 
Orientation
Gas Valve Stages
Motor/Blower Type
Add-Ons
 
In-Stock Free ShippingNo Sales Tax* (Except IL)$1,401.00Buy Now
No Sales Tax* (Except FL)$1,401.00Visit Site
Only 4 In-Stock
Ships Monday, Jan 22nd
Enter your ZIP Code below to see an estimated arrival time of delivery to your home or business.
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
  • Product Description
  • 17
    Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features

    Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GMEC96 two-stage, multi-speed furnace was designed to provide premium efficiency at an affordable price. It features Goodman's superior heat exchanger design for the primary heat exchanger and an additional secondary heat exchanger to ensure that your energy dollars aren't being vented out of your home. This combination results in a furnace that converts 96% of the energy used directly into heat for your home, Goodman's highest mark for a two-stage furnace. Instead of a standard multi-speed blower motor, the GMEC961205DN utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GMEC96 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GMEC96.

    Product Features

    Advanced Heat Exchanger Design
    The GMEC96 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used in construction for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.

    Secondary Heat Exchanger
    This furnace produces additional heat without using more fuel by directing combustion gases through a secondary heat exchanger before they are vented. To prevent damage from the gas as it cools, this secondary heat exchanger is made of corrosion-resistant stainless steel and it is sloped to prevent condensate build-up.

    Quiet Comfort
    Goodman takes great pride in producing equipment that doesn't disrupt your home. The blower, motor, and gas valve of the GMEC961205DN were selected for their incredibly low sound levels. Additionally, this unit's fan speed options make it easy to maintain virtually silent circulation.

    Venting Options
    The GMEC961205DN offers several venting options to streamline installation in a variety of applications. It can be used in either a two-pipe direct vent setup or a single-pipe configuration with combustion air provided from within your home. Additionally, it support both top and side venting options.

    Secure Cabinet
    All GMEC96 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is lined with foil-insulation to prevent heat loss and the return side of the cabinet is solid and airtight.

    Easy Integration
    The GMEC961205DN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.

Specifications
General Information
Type
Gas Furnace
Product Line
GMEC96
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Type Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Multi-Speed
Orientation Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
UPC
663051553989
Performance
Nominal Heating Capacity
120000 BTU
High Fire Input
120000 BTU
High Fire Output
115200 BTU
Low Fire Input
84000 BTU
Low Fire Output
80640 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
2000 CFM
Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
13.3 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Product Height
34.5 Inches
Product Width
24.5 Inches
Product Depth
28.75 Inches
Shipping Weight
154 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7423790
Features
Features

    Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GMEC96 two-stage, multi-speed furnace was designed to provide premium efficiency at an affordable price. It features Goodman's superior heat exchanger design for the primary heat exchanger and an additional secondary heat exchanger to ensure that your energy dollars aren't being vented out of your home. This combination results in a furnace that converts 96% of the energy used directly into heat for your home, Goodman's highest mark for a two-stage furnace. Instead of a standard multi-speed blower motor, the GMEC961205DN utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GMEC96 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GMEC96.

    Product Features

    Advanced Heat Exchanger Design
    The GMEC96 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used in construction for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.

    Secondary Heat Exchanger
    This furnace produces additional heat without using more fuel by directing combustion gases through a secondary heat exchanger before they are vented. To prevent damage from the gas as it cools, this secondary heat exchanger is made of corrosion-resistant stainless steel and it is sloped to prevent condensate build-up.

    Quiet Comfort
    Goodman takes great pride in producing equipment that doesn't disrupt your home. The blower, motor, and gas valve of the GMEC961205DN were selected for their incredibly low sound levels. Additionally, this unit's fan speed options make it easy to maintain virtually silent circulation.

    Venting Options
    The GMEC961205DN offers several venting options to streamline installation in a variety of applications. It can be used in either a two-pipe direct vent setup or a single-pipe configuration with combustion air provided from within your home. Additionally, it support both top and side venting options.

    Secure Cabinet
    All GMEC96 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is lined with foil-insulation to prevent heat loss and the return side of the cabinet is solid and airtight.

    Easy Integration
    The GMEC961205DN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.

Specifications
General Information
Type
Gas Furnace
Product Line
GMEC96
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Type Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Multi-Speed
Orientation Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
UPC
663051553989
Performance
Nominal Heating Capacity
120000 BTU
High Fire Input
120000 BTU
High Fire Output
115200 BTU
Low Fire Input
84000 BTU
Low Fire Output
80640 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
2000 CFM
Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
13.3 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Product Height
34.5 Inches
Product Width
24.5 Inches
Product Depth
28.75 Inches
Shipping Weight
154 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7423790
Product Specs
+
Specifications
General Information
Type
Gas Furnace
Product Line
GMEC96
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Type Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Multi-Speed
Orientation Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
UPC
663051553989
Performance
Nominal Heating Capacity
120000 BTU
High Fire Input
120000 BTU
High Fire Output
115200 BTU
Low Fire Input
84000 BTU
Low Fire Output
80640 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
2000 CFM
Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
13.3 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Product Height
34.5 Inches
Product Width
24.5 Inches
Product Depth
28.75 Inches
Shipping Weight
154 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7423790
Reviews
(17)
+
Goodman GMEC961205DN Reviews & Ratings
100% of Reviewers Recommend This Product
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
How-To Articles
+
Manuals
+
 
 
×
Goodman GMEC96 - 120,000 BTU - Gas-Fired Furnace - NG - 96% AFUE - Two-Stage - Upflow/Horizontal - Multi-Speed
+
Reset View

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort Tumbler
View eComfort LinkedIn Company Profile