Answer:This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson Supply location near you.
How Do I Update My Pickup Location?
Answer:The nearest pickup location within a 50-mile radius is automatically chosen when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
How Do I Place a Local Pickup Order?
Answer:Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
When Can Items Be Picked Up?
Answer:Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Orders that have not been picked up within two business days may be cancelled. You should opt to have your items shipped if you are not able to pick them up promptly.
Who Can Pick Up My Order?
Answer:You will be prompted to enter the name, mobile phone, and email address of the person who will be picking up the order during checkout. We will use this information to ensure the order is picked up by an authorized individual.
Why Can't I Select Local Pickup for Some Items?
Answer:Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Why Can't I Select Shipping for Some Items?
Answer:Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Which Payment Methods Are Accepted?
Answer:Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Expert Recommended AccessoriesSelected by Ken, our Expert
Required Accessories9
These accessories are required to properly setup/install this product.
Optional Accessories10
Features
Fujitsu's Multizone systems can have a multitude of combinations with wall mounted, compact cassette or slim duct type indoor units. Mix-and-match flexibility of evaporator type and capacity allows you to choose the indoor unit that best fits the application, whether it be hidden or showcased. These systems are ideal for nursing homes, doctor's offices, condominiums, apartments and residences - any place where individual cooling or heating is needed.
Inverter Technology
Inverter technology drives the compressor, allowing it to match output to demand. The result: a more stable and comfortable temperature within the space. This type of operation removes more moisture, reduces short-cycling, and improves efficiency.
Corrosion Resistant Heat Exchanger
Fujitsu applies a blue fin coating to the heat exchanger of their outdoor condensers. This improves their resistance to many common sources of corrosion and extends their longevity.
Advanced Filtration
A washable ion deodorizing filter uses fine ceramic particles to capture and remove odors. An apple catechin filter isolates and deactivates mold, bacteria, and dust. This combination creates a clean and healthy air flow from your indoor unit.
Timer Function
You can set a sleep timer to gradually decrease the output after you have gone to bed. It also supports a 24-hour timer, allowing you to set on and off time once per day. These timers allow you to curtail energy use without sacrificing comfort.
Dehumidify and Cool
Dry Mode demonstrates the Halcyon HFI's versatility. In addition to providing moderate cooling, dry mode also dehumidifies your zone.
Airflow Control
Swing mode disperses conditioned air evenly across your zone, resulting in consistent and thorough heating and cooling. Swing mode can be used with this unit's auto fan mode and auto changeover for automated comfort in rooms of all shapes and sizes.
Power Diffuser
This unit includes an airflow louver known as a power diffuser that directs heated air to the floor of the room and cold air outwards to blanket the room. This diffuser uses temperature sensors to ensure that your airflow is ideal in any application.
Economy Mode
The Halcyon HFI features an Economy Mode restricts the unit's maximum output to decrease energy use and increase savings. This mode also increases the unit's dehumidification capabilities during cooling operations and in Dry Mode.
Recommended line set sizes for indoor unit connectivity:
ASUH18LPAS: 1/4" x 1/2" Line Set (Qty 2)
Product Includes
(1) Fujitsu - 36k BTU - RLXFZ1 Outdoor Condenser - For 2-4 Zones (AOU36RLXFZ1)
(2) Fujitsu - 18k BTU- Wall Mounted Unit - For Multi or Single-Zone (ASUH18LPAS)
Product Note
This product requires the following accessories for installation:
Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
Connecting Cable - This durable, insulated cable provides power to your indoor units from your outdoor condenser.
Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
Adding these accessories to your order will provide a complete, ready-to-install mini split system. All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
(1) Fujitsu - 36k BTU - RLXFZ1 Outdoor Condenser - For 2-4 Zones (AOU36RLXFZ1)
(2) Fujitsu - 18k BTU- Wall Mounted Unit - For Multi or Single-Zone (ASUH18LPAS)
F2H36W18180000
Overview
Product Category
Mini Split Heat Pump System
General Information
Type
Wall Mounted
Product Line
Halcyon HFI
Product Category
Mini Split Heat Pump System
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Number of ZonesA zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s) Indoor Unit Size(s)Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
18 + 18
Outdoor Unit Size
36000 BTU
DOE Regional Compliance DOE Regional ComplianceIn 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
31600 BTU
Heating Capacity
35800 BTU
Cooling Power Input
3980 Watts
Heating Power Input
3660 Watts
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
14 F
SEER2 SEER2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
19.0
EER2 EER2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
10.0
HSPF2 HSPF2The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. HSPF2 (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF2, the more efficient the system.
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
4
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
36000
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
55 dB
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Minimum Outdoor Temperature for HeatingThis is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
30 Amps
Dimensions
Maximum Line Length
230 Feet
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Line Set C Liquid Connection
1/4 Inch
Line Set C Gas Connection
3/8 Inch
Line Set D Liquid Connection
1/4 Inch
Line Set D Gas Connection
1/2 Inch
Product Height
32 11/16 Inches
Product Width
35 7/16 Inches
Product Depth
13 Inches
Product Weight
149 Pounds
Shipping Width
41 5/16 Inches
Shipping Height
38 3/16 Inches
Shipping Depth
17 1/2 Inches
Shipping Weight
165 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Operating Mode Operating ModeSome products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Remote Control
Wireless
Indoor Unit Size(s) Indoor Unit Size(s)Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
18
Installation Location
Indoor
Performance
Cooling BTU
18000
Cooling Capacity
18000 BTU
Maximum Air Flow
530 CFM
Minimum Air Flow
241 CFM
Minimum Sound Level
26 dB
Maximum Sound Level Maximum Sound LevelSound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
44 dB
Electrical Data
Voltage
208/226 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
1/2 Inch
Liquid Connection Size
1/4 Inch
Product Height
11 Inches
Product Width
38 9/16 Inches
Product Depth
9 7/16 Inches
Product Weight
37 Pounds
Shipping Height
12 11/16 Inches
Shipping Width
42 7/16 Inches
Shipping Depth
13 5/8 Inches
Shipping Weight
46 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Parts WarrantyA warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Reviews
(2)
Fujitsu F2H36W18180000 Reviews & Ratings
Customer Photos and Videos
How-To Articles
How to Pick the Perfect Mini Split Wall Mounted Indoor Unit
Wall-mounted units are the most commonly found, most affordable option for indo...