On Sale

Hover to zoom
1 Of 5
Fujitsu Ceiling Cassette 2-Zone System - 24,000 BTU Outdoor - 7k + 7k Indoor - 18.0 SEER
Model: F2H24C07070000
+
Share This Product
-
Product Description
-
1Reviews
-
Product Q&A
-
Recommended Accessories
-
How-To Articles
-
Manuals
Product Description
+−
Features
Features
- Inverter Technology
- Inverter technology drives the compressor, allowing it to match output to demand. The result: a more stable and comfortable temperature within the space. This type of operation removes more moisture, reduces short-cycling, and improves efficiency.
- Fresh Air Intake
- Fresh air can be added to your system with Fujitsu's optional Fresh Air Intake Kit. This 4"; adaptor connects directly to the indoor unit, increasing indoor air quality by diluting stale and polluted air. A field supplied fan is required for circulation.
- Corrosion Resistant Heat Exchanger
- Fujitsu applies a Blue Fin coating to the heat exchanger of their multi-zone outdoor condensers. This improves their resistance to many common sources of corrosion and extends their longevity.
- Timer Function
- The indoor units offer 7-day programmability with two unique on/off events on each individual day. This allows you to customize heating and cooling operations to suit your personal schedule, improving energy efficiency without compromising comfort.
- Intelligent Temperature Calculation
- Rooms with raised ceilings heat differently than traditionally sized rooms. The indoor units can be set to account for ceiling height when making temperature calculations. This keeps you comfortable, even in rooms with unconventional heating patterns.
- Condensate Protection
- There is a condensate pump in the ceiling cassette units. This pump removes condensation build up from your system, protecting your home from water damage, and keeping your system running efficiently.
- Multiple Operating Modes
- Fujitsu's ceiling cassette units offer multiple operating modes to match all of your needs. These include Dry Mode, to dehumidify rooms, Quiet Mode, to operate a lower decibel level, and Economy Mode, to decrease energy consumption.
- Two-Stage Turbo Fan
- Fujitsu employs a two-stage turbo fan to optimize the distribution of air over this unit's heat exchanger. By employing two separate currents of air, the turbo fan ensures even temperatures and improves both efficiency and comfort.
- Recommended line set sizes for indoor unit connectivity:
- AUU7RLF: 1/4" x 3/8" Line Set (Qty 2)
- (1) Fujitsu - 24k BTU - Outdoor Condenser - For 2-3 Zones (AOU24RLXFZ)
- (2) Fujitsu - 7k BTU - Ceiling Cassette - For Multi or Single-Zone - Grille Sold Separately (AUU7RLF-NOGRILLE)
- (2) Fujitsu Halcyon HFI - Ceiling Cassette Grille (UTG-CCGFG)
- (2) Fujitsu Wired Remote Controller (UTY-RNNUM)
- Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
- Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
- Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
- Connecting Cable - This durable, insulated cable provides power to your indoor units from your outdoor condenser.
- Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
- Outdoor Condenser Plastic Pad (Optional) - This pad provides an even surface, free of debris, on which to place your outdoor condenser.
- Wall Bracket (Optional) - A simple and sturdy way to mount your outdoor condenser off of the ground.
Fujitsu has been providing efficient and responsible heating and air conditioning solutions for decades. Their experience and dedication can be seen in the F2H24C07070000 ceiling cassette mini split system. If you are looking to provide heating and cooling for multiple zones, or supplement existing heating and air conditioning equipment, the Halcyon HFI mini split system is a reliable and efficient choice. The compact ceiling cassette unit mounts easily in your ceiling, allowing you to install the unit at the center of your zone for ideal airflow coverage. With a wide range of operating modes, this system can be customized to suit any of your comfort needs.
Product Includes
Product Note
This product requires the following accessories for installation:
Specifications
General Information
Type
Ceiling Cassette
Product Line
Halcyon HFI
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7 + 7
Outdoor Unit Size
24000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
14100 BTU
Heating Capacity
18800 BTU
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
18.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.5
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9.5
Cooling Power Input
1200 Watts
Heating Power Input
1370 Watts
Minimum Operating Temperature
5 F
Maximum Operating Temperature
115 F
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
202 Pounds
Shipping Weight
202 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
4397405
AOU24RLXFZ Specifications+
AUU7RLF-NOGRILLE Specifications+
UTG-CCGFG Specifications+
UTY-RNNUM Specifications+
Features
Features
- Inverter Technology
- Inverter technology drives the compressor, allowing it to match output to demand. The result: a more stable and comfortable temperature within the space. This type of operation removes more moisture, reduces short-cycling, and improves efficiency.
- Fresh Air Intake
- Fresh air can be added to your system with Fujitsu's optional Fresh Air Intake Kit. This 4"; adaptor connects directly to the indoor unit, increasing indoor air quality by diluting stale and polluted air. A field supplied fan is required for circulation.
- Corrosion Resistant Heat Exchanger
- Fujitsu applies a Blue Fin coating to the heat exchanger of their multi-zone outdoor condensers. This improves their resistance to many common sources of corrosion and extends their longevity.
- Timer Function
- The indoor units offer 7-day programmability with two unique on/off events on each individual day. This allows you to customize heating and cooling operations to suit your personal schedule, improving energy efficiency without compromising comfort.
- Intelligent Temperature Calculation
- Rooms with raised ceilings heat differently than traditionally sized rooms. The indoor units can be set to account for ceiling height when making temperature calculations. This keeps you comfortable, even in rooms with unconventional heating patterns.
- Condensate Protection
- There is a condensate pump in the ceiling cassette units. This pump removes condensation build up from your system, protecting your home from water damage, and keeping your system running efficiently.
- Multiple Operating Modes
- Fujitsu's ceiling cassette units offer multiple operating modes to match all of your needs. These include Dry Mode, to dehumidify rooms, Quiet Mode, to operate a lower decibel level, and Economy Mode, to decrease energy consumption.
- Two-Stage Turbo Fan
- Fujitsu employs a two-stage turbo fan to optimize the distribution of air over this unit's heat exchanger. By employing two separate currents of air, the turbo fan ensures even temperatures and improves both efficiency and comfort.
- Recommended line set sizes for indoor unit connectivity:
- AUU7RLF: 1/4" x 3/8" Line Set (Qty 2)
- (1) Fujitsu - 24k BTU - Outdoor Condenser - For 2-3 Zones (AOU24RLXFZ)
- (2) Fujitsu - 7k BTU - Ceiling Cassette - For Multi or Single-Zone - Grille Sold Separately (AUU7RLF-NOGRILLE)
- (2) Fujitsu Halcyon HFI - Ceiling Cassette Grille (UTG-CCGFG)
- (2) Fujitsu Wired Remote Controller (UTY-RNNUM)
- Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
- Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
- Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
- Connecting Cable - This durable, insulated cable provides power to your indoor units from your outdoor condenser.
- Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
- Outdoor Condenser Plastic Pad (Optional) - This pad provides an even surface, free of debris, on which to place your outdoor condenser.
- Wall Bracket (Optional) - A simple and sturdy way to mount your outdoor condenser off of the ground.
Fujitsu has been providing efficient and responsible heating and air conditioning solutions for decades. Their experience and dedication can be seen in the F2H24C07070000 ceiling cassette mini split system. If you are looking to provide heating and cooling for multiple zones, or supplement existing heating and air conditioning equipment, the Halcyon HFI mini split system is a reliable and efficient choice. The compact ceiling cassette unit mounts easily in your ceiling, allowing you to install the unit at the center of your zone for ideal airflow coverage. With a wide range of operating modes, this system can be customized to suit any of your comfort needs.
Product Includes
Product Note
This product requires the following accessories for installation:
Specifications
General Information
Type
Ceiling Cassette
Product Line
Halcyon HFI
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7 + 7
Outdoor Unit Size
24000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
14100 BTU
Heating Capacity
18800 BTU
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
18.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.5
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9.5
Cooling Power Input
1200 Watts
Heating Power Input
1370 Watts
Minimum Operating Temperature
5 F
Maximum Operating Temperature
115 F
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
202 Pounds
Shipping Weight
202 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
4397405
AOU24RLXFZ Specifications+
AUU7RLF-NOGRILLE Specifications+
UTG-CCGFG Specifications+
UTY-RNNUM Specifications+
Product Specs
+−
Specifications
General Information
Type
Ceiling Cassette
Product Line
Halcyon HFI
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
7 + 7
Outdoor Unit Size
24000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Cooling Capacity
14100 BTU
Heating Capacity
18800 BTU
SEER
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
18.0
EER
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.5
HSPF
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9.5
Cooling Power Input
1200 Watts
Heating Power Input
1370 Watts
Minimum Operating Temperature
5 F
Maximum Operating Temperature
115 F
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
5 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
202 Pounds
Shipping Weight
202 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
4397405
AOU24RLXFZ Specifications+
AUU7RLF-NOGRILLE Specifications+
UTG-CCGFG Specifications+
UTY-RNNUM Specifications+
Product Q&A
+−
Be the first to ask a question.
Recommended Accessories
+−

Expert Recommended Accessories
Hand Picked By Our Expert Chris
Required Accessories
Add All Required
Optional Accessories
How-To Articles
+−
By Chris Z.
Manuals
+−
+
Ask Chris, Our Product Expert, A Question!
*Required Fields

+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.

Media Gallery
Fujitsu Ceiling Cassette 2-Zone System - 24,000 BTU Outdoor - 7k + 7k Indoor - 18.0 SEER









×
Customer Review Images
