Fujitsu - 12k BTU Cooling + Heating - RL2 115V Wall Mounted Air Conditioning System - 16.0 SEER

Fujitsu - 12k BTU Cooling + Heating - RL2 115V Wall Mounted Air Conditioning System - 16.0 SEER
Our Price
Compare Prices
Shipping Info
Model: 12RL2
4.0 out of 54.0 out of 54.0 out of 54.0 out of 54.0 out of 5
Number of Reviews (2)
Write A Review
$1,237.91
$1,176.01

In-Stock
Ships in 2-3 Business Days
Shipping Crate Icon
Free Shipping
Free Lift Gate Service - 
System BTU/h
Add-Ons
In-Stock
Ships in 2-3 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • 2
    Reviews
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Fujitsu has been providing efficient and responsible heating and air conditioning solutions for decades. Their experience and dedication can be seen in the 12RL2 wall mounted mini split system. This system is a single zone heating and cooling solution for use in 115 volt electrical systems. If you are looking to provide heating and cooling for an individual space, or to supplement existing heating and air conditioning equipment, the 12RL2 mini split system is a reliable and efficient choice for low voltage applications. This system has an array of effective operating modes that allow you to customize operations to suit your comfort, making it an intelligent addition to any home or business.
  • Inverter Technology
  • The 12RL2 outdoor condenser uses an inverter to drive the compressor, allowing it to match its output to the amount of heating or cooling required by a space, even as conditions change. This enables the system to maintain a more stable temperature.
  • Timer Function
  • With this unit, you can set a sleep timer to gradually decrease the heating or cooling output after you have gone to bed. This timer allows you to curtail energy use without sacrificing comfort.
  • Dehumidify and Cool
  • Dry Mode demonstrates the ASU12RL2's versatility. In addition to providing moderate cooling, dry mode also dehumidifies your zone.
  • Airflow Control
  • The airflow direction of this indoor unit may be set to swing automatically between its seven vertical positions. This disperses the hot or cold air evenly across your zone, resulting in consistent and thorough heating and cooling.
  • Concentrated Heating and Cooling
  • The 12RL2 mini split system has a powerful operation mode. This operating mode runs your indoor unit at maximum power for up to twenty minutes or until your zone reaches the desired temperature, whichever occurs first.
  • Quiet Operating Mode
  • The ASU12RL2 may be set in a quiet operating mode. This operating mode limits airflow slightly to reduce fan noise from the unit, allowing you to enjoy supremely quiet comfort.
  • Economy Mode
  • The 12RL2 system features an Economy Mode restricts the unit's maximum output to decrease energy use and increase savings. This mode also increases the unit's dehumidification capabilities during cooling operations and in Dry Mode.
  • Product Includes
    • (1) Fujitsu - 12k BTU - RL2 Outdoor Condenser - Single Zone Only (AOU12RL2)
    • (1) Fujitsu 12k BTU Wall Mounted Unit - For Single-Zone (ASU12RL2)
    Product Note
    This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Cable - This durable, insulated cable provides power to your indoor unit from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system. All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
General Information
Type
Wall Mounted
Product Line
Halcyon
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Outdoor Unit Size
12000 BTU
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Heating Capacity
14000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
16
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
10
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9
Minimum Operating Temperature
15 F
Maximum Operating Temperature
15 F
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
15 F
Minimum Outdoor Temperature for Cooling
15 F
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15 Amps
Recommended Breaker Size
20 Amps
Dimensions
Suction Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Weight
85 Pounds
Shipping Weight
92 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Warranty Learn More
Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
10 Limited Years
AOU12RL2 Specifications+
General Information
Type
Outdoor Condenser
Product Line
RL2
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
12000
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
51 dB
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
15 F
Minimum Outdoor Temperature for Cooling
15 F
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
20 Amps
Dimensions
Maximum Line Length
66 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 1/4 Inches
Product Width
26 Inches
Product Depth
11 17/48 Inches
Product Weight
69 Pounds
Shipping Height
24 1/16 Inches
Shipping Width
31 3/8 Inches
Shipping Weight
73 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
ASU12RL2 Specifications+
General Information
Type
Wall Mounted
Product Line
RL2
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Remote Control
Wireless
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Maximum Air Flow
436 CFM
Minimum Air Flow
191 CFM
Minimum Sound Level
23 dB
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
43 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
10 5/16 Inches
Product Depth
8 1/8 Inches
Product Weight
16 Pounds
Shipping Width
34 1/4 Inches
Shipping Weight
20 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Features
Features
    Fujitsu has been providing efficient and responsible heating and air conditioning solutions for decades. Their experience and dedication can be seen in the 12RL2 wall mounted mini split system. This system is a single zone heating and cooling solution for use in 115 volt electrical systems. If you are looking to provide heating and cooling for an individual space, or to supplement existing heating and air conditioning equipment, the 12RL2 mini split system is a reliable and efficient choice for low voltage applications. This system has an array of effective operating modes that allow you to customize operations to suit your comfort, making it an intelligent addition to any home or business.
  • Inverter Technology
  • The 12RL2 outdoor condenser uses an inverter to drive the compressor, allowing it to match its output to the amount of heating or cooling required by a space, even as conditions change. This enables the system to maintain a more stable temperature.
  • Timer Function
  • With this unit, you can set a sleep timer to gradually decrease the heating or cooling output after you have gone to bed. This timer allows you to curtail energy use without sacrificing comfort.
  • Dehumidify and Cool
  • Dry Mode demonstrates the ASU12RL2's versatility. In addition to providing moderate cooling, dry mode also dehumidifies your zone.
  • Airflow Control
  • The airflow direction of this indoor unit may be set to swing automatically between its seven vertical positions. This disperses the hot or cold air evenly across your zone, resulting in consistent and thorough heating and cooling.
  • Concentrated Heating and Cooling
  • The 12RL2 mini split system has a powerful operation mode. This operating mode runs your indoor unit at maximum power for up to twenty minutes or until your zone reaches the desired temperature, whichever occurs first.
  • Quiet Operating Mode
  • The ASU12RL2 may be set in a quiet operating mode. This operating mode limits airflow slightly to reduce fan noise from the unit, allowing you to enjoy supremely quiet comfort.
  • Economy Mode
  • The 12RL2 system features an Economy Mode restricts the unit's maximum output to decrease energy use and increase savings. This mode also increases the unit's dehumidification capabilities during cooling operations and in Dry Mode.
  • Product Includes
    • (1) Fujitsu - 12k BTU - RL2 Outdoor Condenser - Single Zone Only (AOU12RL2)
    • (1) Fujitsu 12k BTU Wall Mounted Unit - For Single-Zone (ASU12RL2)
    Product Note
    This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Cable - This durable, insulated cable provides power to your indoor unit from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system. All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
General Information
Type
Wall Mounted
Product Line
Halcyon
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Outdoor Unit Size
12000 BTU
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Heating Capacity
14000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
16
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
10
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9
Minimum Operating Temperature
15 F
Maximum Operating Temperature
15 F
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
15 F
Minimum Outdoor Temperature for Cooling
15 F
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15 Amps
Recommended Breaker Size
20 Amps
Dimensions
Suction Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Weight
85 Pounds
Shipping Weight
92 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Warranty Learn More
Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
10 Limited Years
AOU12RL2 Specifications+
General Information
Type
Outdoor Condenser
Product Line
RL2
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
12000
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
51 dB
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
15 F
Minimum Outdoor Temperature for Cooling
15 F
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
20 Amps
Dimensions
Maximum Line Length
66 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 1/4 Inches
Product Width
26 Inches
Product Depth
11 17/48 Inches
Product Weight
69 Pounds
Shipping Height
24 1/16 Inches
Shipping Width
31 3/8 Inches
Shipping Weight
73 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
ASU12RL2 Specifications+
General Information
Type
Wall Mounted
Product Line
RL2
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Remote Control
Wireless
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Maximum Air Flow
436 CFM
Minimum Air Flow
191 CFM
Minimum Sound Level
23 dB
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
43 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
10 5/16 Inches
Product Depth
8 1/8 Inches
Product Weight
16 Pounds
Shipping Width
34 1/4 Inches
Shipping Weight
20 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Product Specs
+
Specifications
General Information
Type
Wall Mounted
Product Line
Halcyon
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Learn More
Number of Zones
A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Outdoor Unit Size
12000 BTU
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Heating Capacity
14000 BTU
SEER Learn More
SEER
SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
16
EER Learn More
EER
EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
10
HSPF Learn More
HSPF
HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9
Minimum Operating Temperature
15 F
Maximum Operating Temperature
15 F
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
15 F
Minimum Outdoor Temperature for Cooling
15 F
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15 Amps
Recommended Breaker Size
20 Amps
Dimensions
Suction Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Weight
85 Pounds
Shipping Weight
92 Pounds
Certifications
ETL Listed
Yes
Warranty Information
Warranty Learn More
Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
10 Limited Years
AOU12RL2 Specifications+
General Information
Type
Outdoor Condenser
Product Line
RL2
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
12000
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
51 dB
Low Ambient Heating
No
Minimum Outdoor Temperature for Heating Learn More
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
15 F
Minimum Outdoor Temperature for Cooling
15 F
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
20 Amps
Dimensions
Maximum Line Length
66 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 1/4 Inches
Product Width
26 Inches
Product Depth
11 17/48 Inches
Product Weight
69 Pounds
Shipping Height
24 1/16 Inches
Shipping Width
31 3/8 Inches
Shipping Weight
73 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
ASU12RL2 Specifications+
General Information
Type
Wall Mounted
Product Line
RL2
Operating Mode Learn More
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Remote Control
Wireless
Indoor Unit Size(s) Learn More
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Maximum Air Flow
436 CFM
Minimum Air Flow
191 CFM
Minimum Sound Level
23 dB
Maximum Sound Level Learn More
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
43 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
10 5/16 Inches
Product Depth
8 1/8 Inches
Product Weight
16 Pounds
Shipping Width
34 1/4 Inches
Shipping Weight
20 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Reviews
(2)
+
Fujitsu 12RL2 Reviews & Ratings
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Fujitsu - 12k BTU Cooling + Heating - RL2 115V Wall Mounted Air Conditioning System - 16.0 SEER
Fujitsu 12RL2
+
Reset View
Fujitsu 12RL2
Fujitsu 12RL2
Fujitsu 12RL2
Fujitsu 12RL2
Fujitsu 12RL2
×
Customer Review Images