  • Product Description
  • Reviews
  • Product Q&A
  • How-To Articles
  • Manuals
Product Description
+
Features
Features

    EM-WD102D8-SL2, WarmFlo Two Stage Electric Plenum Duct Heater - 18" Downflow, 10 kW - 34,000 BTU

    Our WarmFlo Select Plenum Heater makes ordering and installing a WarmFlo plenum heater easier than ever. We have integrated the control and interface modules into one discrete system which includes all of the features and flexibility of WarmFlo EM-WD102D8-SL2 II plenum heaters. In other words, you no longer have to worry about which interface module or chip code you need whether you are installing the plenum heater in conjunction with air conditioning, without air conditioning, or with a single stage heat pump.

    How does WarmFlo work with an air source heat pump?

    The WarmFlo controller receives temperature information from the warm air plenum sensor and the outside sensor to monitor the heating system performance. Using data from the sensors, the WarmFlo intelligent controller automatically establishes a warm air delivery temperature ideal for the specific outdoor temperature. As outside temperature drops, the air source heat pump output decreases and the warm air required to heat the home increases. The WarmFlo plenum heater automatically adds heat in 500 watt increments to meet the heating requirements of the home.

    Benefits of EM-WD102D8-SL2, WarmFlo Two Stage Electric Plenum Duct Heater at a glance:

      Outstanding 100% Efficiency.

    • Uses low electric kWh rate for 91+ % of the annual heating.
    • No chip code selection required.
    • Application selection dial HP or non-HP.
    • Duel-Fuel Capability.
    • One model, can be used with a Gas/Oil/Wood Furnace.
    • Variable Speed Motor Furnaces and Air Handlers Comparable.
    • Quiet operation with DC relays.
    • Energy control selector.
    • Simple 4-wire conventional thermostat wiring used for both heat pump heating and air conditioning systems.
    WarmFlo Select Electric Plenum Heater Series Other Standard Features:
    • Provides a control technology for utilizing the high efficiencies of a heat pump down to at least 0 F.
    • Generally provides $400+ annual operating savings compared to dual fuel HP installations.
    • Proportional control - outlet temperature ramps up with decrease in outdoor temperature.
    • Overcomes heat pump "cold air syndrome".
    • Mini Demand Control or Load Shed.
    • Setup dial selections - Heat Pump or non-Heat Pump.
    • Heating capacity determined by outdoor temperature.
    • Thermostat or end switch connection (R and W).
    • Load management control provisions.
    • Heavy duty sheet metal enclosure.
    • Approved zero clearance above A-coil or furnace.
    • Single conventional 4-wire thermostat control.
    • Spin finned rod elements (20-year warranty).
    • 2-year parts warranty.
    • Can be added to most 100-amp service entrances - 5 kW firm load, 5 kW shed load.
    • Typically less airflow upgrades and less baffling requirements.
    • Quiet operation with individual DC relays.
    • Energy control selector.
    • Factory tested.
    • Made in the USA.
    WarmFlo Select Electric Plenum Heater Series Warranty:
    • 2 years parts / 20 years Heating Elements.

    All of the WarmFlo Plenum Duct Electric Heaters makes ordering and installing a WarmFlo plenum heater easier than ever. We have integrated the control and interface modules into one discrete system which includes all of the features and flexibility of our WarmFlo II plenum heaters. In other words, you no longer have to worry about which interface module or chip code you need whether you are installing the plenum heater in conjunction with air conditioning, without air conditioning, or with a single stage heat pump.

Specifications
General Information
Product Line
WarmFlo
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Orientation Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Performance
Heating Capacity
10 kW
Minimum Air Flow
700 CFM
Electrical Data
Voltage
240 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
60 Amps
Dimensions
Product Height
11.125 Inches
Product Width
16.5 Inches
Product Depth
27 Inches
Product Weight
24 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heating Element Warranty
20 Years
Features
Features

    EM-WD102D8-SL2, WarmFlo Two Stage Electric Plenum Duct Heater - 18" Downflow, 10 kW - 34,000 BTU

    Our WarmFlo Select Plenum Heater makes ordering and installing a WarmFlo plenum heater easier than ever. We have integrated the control and interface modules into one discrete system which includes all of the features and flexibility of WarmFlo EM-WD102D8-SL2 II plenum heaters. In other words, you no longer have to worry about which interface module or chip code you need whether you are installing the plenum heater in conjunction with air conditioning, without air conditioning, or with a single stage heat pump.

    How does WarmFlo work with an air source heat pump?

    The WarmFlo controller receives temperature information from the warm air plenum sensor and the outside sensor to monitor the heating system performance. Using data from the sensors, the WarmFlo intelligent controller automatically establishes a warm air delivery temperature ideal for the specific outdoor temperature. As outside temperature drops, the air source heat pump output decreases and the warm air required to heat the home increases. The WarmFlo plenum heater automatically adds heat in 500 watt increments to meet the heating requirements of the home.

    Benefits of EM-WD102D8-SL2, WarmFlo Two Stage Electric Plenum Duct Heater at a glance:

      Outstanding 100% Efficiency.

    • Uses low electric kWh rate for 91+ % of the annual heating.
    • No chip code selection required.
    • Application selection dial HP or non-HP.
    • Duel-Fuel Capability.
    • One model, can be used with a Gas/Oil/Wood Furnace.
    • Variable Speed Motor Furnaces and Air Handlers Comparable.
    • Quiet operation with DC relays.
    • Energy control selector.
    • Simple 4-wire conventional thermostat wiring used for both heat pump heating and air conditioning systems.
    WarmFlo Select Electric Plenum Heater Series Other Standard Features:
    • Provides a control technology for utilizing the high efficiencies of a heat pump down to at least 0 F.
    • Generally provides $400+ annual operating savings compared to dual fuel HP installations.
    • Proportional control - outlet temperature ramps up with decrease in outdoor temperature.
    • Overcomes heat pump "cold air syndrome".
    • Mini Demand Control or Load Shed.
    • Setup dial selections - Heat Pump or non-Heat Pump.
    • Heating capacity determined by outdoor temperature.
    • Thermostat or end switch connection (R and W).
    • Load management control provisions.
    • Heavy duty sheet metal enclosure.
    • Approved zero clearance above A-coil or furnace.
    • Single conventional 4-wire thermostat control.
    • Spin finned rod elements (20-year warranty).
    • 2-year parts warranty.
    • Can be added to most 100-amp service entrances - 5 kW firm load, 5 kW shed load.
    • Typically less airflow upgrades and less baffling requirements.
    • Quiet operation with individual DC relays.
    • Energy control selector.
    • Factory tested.
    • Made in the USA.
    WarmFlo Select Electric Plenum Heater Series Warranty:
    • 2 years parts / 20 years Heating Elements.

    All of the WarmFlo Plenum Duct Electric Heaters makes ordering and installing a WarmFlo plenum heater easier than ever. We have integrated the control and interface modules into one discrete system which includes all of the features and flexibility of our WarmFlo II plenum heaters. In other words, you no longer have to worry about which interface module or chip code you need whether you are installing the plenum heater in conjunction with air conditioning, without air conditioning, or with a single stage heat pump.

Specifications
General Information
Product Line
WarmFlo
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Orientation Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Performance
Heating Capacity
10 kW
Minimum Air Flow
700 CFM
Electrical Data
Voltage
240 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
60 Amps
Dimensions
Product Height
11.125 Inches
Product Width
16.5 Inches
Product Depth
27 Inches
Product Weight
24 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heating Element Warranty
20 Years
Product Specs
+
Specifications
General Information
Product Line
WarmFlo
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Orientation Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Performance
Heating Capacity
10 kW
Minimum Air Flow
700 CFM
Electrical Data
Voltage
240 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
60 Amps
Dimensions
Product Height
11.125 Inches
Product Width
16.5 Inches
Product Depth
27 Inches
Product Weight
24 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heating Element Warranty
20 Years
Reviews
+
This product has no reviews.
Be the first to voice your opinion on this Electro Industries product.
Product Q&A
+
Be the first to ask a question.
How-To Articles
+
Manuals
+
 
 
×
Electro Industries EM-WD102D8-SL2, WarmFlo Two Stage Electric Plenum Duct Heater-18" Downflow,10kW
+
Reset View

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort Tumbler
View eComfort LinkedIn Company Profile