- Sirius Heat™ Low Ambient Operations
- This outdoor unit supports cooling operations down to 5 degrees Fahrenheit, heating operations down to -22 degrees Fahrenheit and provides up to 100% heating capacity at 0 degrees.
- Wireless Remote Control With "Follow Me" Technology
- This function uses the temperature at the remote's location, instead of the indoor unit's location, to optimize the temperature around you and ensure maximum comfort.
- Auto Restart
- The indoor unit has an auto-restart module that allows the unit to restart automatically and, in the case of a sudden power failure, will restore those setting automatically after power returns.
- 24-Hour Timer Feature
- Third-Party Thermostat Interface
- The DR24VINT1 interface works with Durastar indoor units, enabling third-party Wi-Fi compatible thermostats to control them. It's compatible with various 24V Wi-Fi thermostat brands like Nest, Ecobee, Honeywell, and Proselect for wireless control.
- (1) Durastar - 18k BTU - Outdoor Condenser - For 2 Zones (DRA2U18M1B)
- (2) Durastar - 9k BTU - Wall Mounted - For Multi or Single Zone (DRAW09F1B)
- Please note, installation manuals are not currently included with your mini split. Please see the Manuals tab for the Installation Manual.
- Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor units.
- Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor units to drain locations of your choosing.
- Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
- Connecting Wire - This durable, insulated wire provides power to your indoor units from your outdoor condenser.
- Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
Engineered for comfort, Durastar is backed by resilient technology and will withstand the test of time and nature's elements. Providing energy efficient, value-friendly HVAC equipment for every space, Durastar creates a comfortable environment for any homeowner. Durastar mini-splits are ideal for renovations, remodels and zone-specific heating and cooling needs.
Product Includes
Product Note
California residents see
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
For more information go to: www.p65Warnings.ca.gov
Specifications
Product Includes
- (1) Durastar - 18k BTU - Outdoor Condenser - For 2 Zones (DRA2U18M1B)
- (2) Durastar - 9k BTU - Wall Mounted - For Multi or Single Zone (DRAW09F1B)
DR2H18W0909
Overview
Product Category
Mini Split Heat Pump System
General Information
Type
Wall Mounted
Product Category
Mini Split Heat Pump System
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones
Number of Zones
A zone is a room or area within a building that has its own temperature control.
2
Refrigerant Type
R-410A
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
9 + 9
Base Pan Heater Included
Yes
Outdoor Unit Size
18000 BTU
DOE Regional Compliance
DOE Regional Compliance
In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Performance
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-13 F
Minimum Outdoor Temperature for Cooling
5 F
SEER2
SEER2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. SEER2 (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER2, the more energy efficient the system.
21.0
EER2
EER2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. EER2 (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER2, the more efficient the system.
12.5
HSPF2
HSPF2
The U.S Department of Energy has raised the minimum rating requirements starting in 2023 that include updated testing conditions and metrics to better reflect real-world conditions. HSPF2 (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF2, the more efficient the system.
10.2
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
207787171
DRA2U18M1B
General Information
Type
Outdoor Condenser
Product Category
Mini Split System Components
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
2
Multi-Zone Compatible
Yes
Installation Location
Outdoor
Performance
Cooling BTU
18000
Heating BTU
19000
Maximum Air Flow
1765 CFM
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
58.5 dB
Minimum Outdoor Temperature for Heating
Minimum Outdoor Temperature for Heating
This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-13 F
Minimum Outdoor Temperature for Cooling
5 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
25 Amps
Dimensions
Line Set A Liquid Connection
1/4 Inch
Line Set A Gas Connection
3/8 Inch
Line Set B Liquid Connection
1/4 Inch
Line Set B Gas Connection
3/8 Inch
Product Height
26 1/2 Inches
Product Width
35 1/16 Inches
Product Depth
13 7/16 Inches
Product Weight
100.3 Pounds
Certifications
Energy Star Listed
Yes
ETL Listed
No
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
DRAW09F1B
General Information
Type
Wall Mounted
Product Category
Mini Split System Components
Operating Mode
Operating Mode
Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Indoor Unit Size(s)
Indoor Unit Size(s)
Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
9
Installation Location
Indoor
Remote Included
Yes
Performance
Cooling BTU
9000
Heating BTU
10000
Moisture Removal
37.2 Pints/Hour
Maximum Air Flow
291 CFM
Minimum Air Flow
153 CFM
Minimum Sound Level
24 dB
Maximum Sound Level
Maximum Sound Level
Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
40 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Recommended Breaker Size
15 Amps
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
11 5/8 Inches
Product Width
31 9/16 Inches
Product Depth
7 7/8 Inches
Product Weight
19 Pounds
Certifications
Energy Star Listed
Yes
ETL Listed
No
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Reviews
Durastar DR2H18W0909 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
Product Q&A
Be the First to Ask A Question
Answered by Ken, the eComfort Product Expert
How-To Articles
How to Pick the Perfect Mini Split Wall Mounted Indoor Unit
Wall-mounted units are the most commonly found, most affordable option for indo...
What You Should Know About Mini-Split Wiring
Although they are easier to install than central air conditioning systems, mini...
How to Pick the Perfect Mini Split Floor Mounted Indoor Unit
If you are installing a mini split system but you don't have enough clearance f...
Manuals
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Durastar Wall Mounted 2-Zone System - 18,000 BTU Outdoor - 9k + 9k Indoor - 21.0 SEER2
Customer Review Images