Dunkirk PVSB-6D Standing Pilot, Gas Fired, Steam Boiler, NG, Probe LWCO - 187,500 BTU
Model:
356002000
+
Share This Product
Recommended Accessories

Expert Recommended Accessories
Selected by Ken, our Expert
Optional Accessories
1
$225.00
Factory-Direct
Features
- up to 82.7% AFUE
- Chimney Vented Exhaust
- Cast Iron Heat Exchanger
- Easy Installation in a Wide Variety of Spaces
- Titanium Burner
- Environmentally Friendly
- Built In Low Water Cutoff
- Heat exchanger: 20 years
- Parts: 1 year
Dunkirk PVSB-6D Standing Pilot, Gas Fired, Steam Boiler, NG, Probe LWCO- 187,500 BTU
Dunkirk's Plymouth line of hot water boilers offers a great combination of efficiency and dependability. The PSVB series uses a cast iron heat exchanger to achieve 82.7% AFUE as well as provide reliability for decades. The titanium burners used in the PVSB are incredibly resistant to corrosion, further backing Dunkirk's reputation for dependability. The PVSB allows for easy maintenance, as all of the controls are readily accessible without having to remove the jacket of the boiler. The built in field damper closes automatically when the unit turns off, preventing hot air from escaping through the chimney.
Dunkirk PVSB-6D Standing Pilot, Gas Fired, Steam Boiler Features:Specifications
356002000

Performance
Maximum Input Capacity
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
187500 BTU
DOE Heating Capacity
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
153000 BTU
Net I=B=R Capacity
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
115000 BTU
Efficiency
79.6 %
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
12 Years
General Information
Medium
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Steam
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Primary Vent Pipe Diameter
7 Inches
Supply Connection
2 1/2 Inches
Return Connection
2 1/2 Inches
Product Height
36 3/8 Inches
Product Width
21 Inches
Product Depth
26 1/2 Inches
Product Weight
512 Pounds
Reviews
Dunkirk 356002000 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
How-To Articles
How to Pick the Perfect City Multi Outdoor Unit
When dealing with very large buildings with many different zones, choosing a hea...
Smart, Safe, Clean Home Tips
Americans spend around 90 percent of their time indoors, whether it's working, ...
Heat Pump Hybrid Water Heater Buyers Guide
If your gas or electric water heater is nearing the end of its life, replacing ...
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.

Media Gallery
Dunkirk PVSB-6D Standing Pilot, Gas Fired, Steam Boiler, NG, Probe LWCO - 187,500 BTU


Customer Review Images