Burnham K2WT-080 - 74K BTU - 94.0% AFUE - Hot Water Gas Boiler - Direct Vent

Burnham K2WT-080 - 74K BTU - 94.0% AFUE - Hot Water Gas Boiler - Direct Vent
Model: K2-080
$2,679.95
Factory-Direct
Ships in 7-14 Business Days
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping & 
Tax-Free (Except IL)
Free Lift Gate Service - 
Add-Ons
 
Factory-Direct
Ships in 7-14 Business Days
Enter your ZIP Code below to see an estimated arrival time of delivery to your home or business.
*We currently CANNOT ship this product to California, Texas or any destination outside of the United States
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
  • Product Description
  • 1
    Reviews
  • 2
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features

    Burnham continues to be on the forefront of home heating technology. By contantly working to improve the efficiency of their boilers, they are able to pass the savings on directly to the homeowner. The K2-080 is the next model in a history of state of the art, economical machines. The K2 line improves upon Burnham's condenser technology, allowing for optimal heating performance at up to 94% AFUE efficiency. The stainless steel body and included wall mount system allow for easy installation and long-term realiabilty. The K2 line also introduces the Sage2.2 system, providing high efficiency heating right out of the box, as well as an easy to use touch screen interface with intuitive menus and graphs. Burnham has strived to deliver the best, most efficient machines for residential heating, and the K2 continues that mission.

    Product Features

    Sage2.2 Control System
    The Sage2.2 provides pre-set, out of the box high performance from day one. If changes are required, the Sage2.2 system has an easy to read and use touchscreen interface built into the boiler. The system provides step-by-step instructions for changing settings as well as running system diagnostics, making the K2 one of the most user friendly boilers on the market.

    Built to be Efficient
    The K2 line was designed to keep costs down, while still being as efficient as possible. With that in mind, the K2 line is designed to be easy to service, allowing for quick, efficient maintenance. Quicker maintenance combined with ease of installtion keeps initial and year-to-year costs down, saving the money over the lifetime of the boiler.

    Manage Multiple Boilers
    Like many of Burnham's other models, the K2 can be linked with other boilers, automatically communicating between each other to serve even the largest of spaces and efficiently heat your home. Using smart features such as "lead/lag cycling" the boilers work in tandem to share the load between all boilers, keeping your home warm while keeping the boilers working efficiently.

    High Altitude Boilers
    Due to Burnham's condensing technology, the K2 model suffers little to no efficieny loss at higher altitudes. With an easily adjustable option built into the boiler, the the K2 model can work at near maximum efficiency up to 10,000 feet. By staying efficient, the K2 eliminates the need to oversize your boiler at higher altitudes.

    Multiple Installation Options
    The K2 model comes with a built-in wall mount allowing for flexibilty in almost any installation situation. The K2's relativley small size and weight allow it to fit in nearly any space.

    Product Includes
    • (1) Burnham K2-080 K2 Hot Water Boiler
    • (1) Wall Mounting Kit
    • (1) Universal Exhaust Vent Termination Kit
    • (1) Miscellanous Parts Kit
Specifications
General Information
Product Line
K2
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Condensing
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
UPC
672616733117
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
80000 BTU
Minimum Input Capacity
16000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
74000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
64000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
94 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Turndown Ratio
5:1
Electrical Data
Voltage
115 Volts
Frequency
60 Hz
Dimensions
Flue Connection Size
2 Inches
Supply Connection
1 Inch
Return Connection
1 Inch
Product Height
35 Inches
Product Width
17 Inches
Product Depth
16.1875 Inches
Shipping Weight
149 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
7163094
Features
Features

    Burnham continues to be on the forefront of home heating technology. By contantly working to improve the efficiency of their boilers, they are able to pass the savings on directly to the homeowner. The K2-080 is the next model in a history of state of the art, economical machines. The K2 line improves upon Burnham's condenser technology, allowing for optimal heating performance at up to 94% AFUE efficiency. The stainless steel body and included wall mount system allow for easy installation and long-term realiabilty. The K2 line also introduces the Sage2.2 system, providing high efficiency heating right out of the box, as well as an easy to use touch screen interface with intuitive menus and graphs. Burnham has strived to deliver the best, most efficient machines for residential heating, and the K2 continues that mission.

    Product Features

    Sage2.2 Control System
    The Sage2.2 provides pre-set, out of the box high performance from day one. If changes are required, the Sage2.2 system has an easy to read and use touchscreen interface built into the boiler. The system provides step-by-step instructions for changing settings as well as running system diagnostics, making the K2 one of the most user friendly boilers on the market.

    Built to be Efficient
    The K2 line was designed to keep costs down, while still being as efficient as possible. With that in mind, the K2 line is designed to be easy to service, allowing for quick, efficient maintenance. Quicker maintenance combined with ease of installtion keeps initial and year-to-year costs down, saving the money over the lifetime of the boiler.

    Manage Multiple Boilers
    Like many of Burnham's other models, the K2 can be linked with other boilers, automatically communicating between each other to serve even the largest of spaces and efficiently heat your home. Using smart features such as "lead/lag cycling" the boilers work in tandem to share the load between all boilers, keeping your home warm while keeping the boilers working efficiently.

    High Altitude Boilers
    Due to Burnham's condensing technology, the K2 model suffers little to no efficieny loss at higher altitudes. With an easily adjustable option built into the boiler, the the K2 model can work at near maximum efficiency up to 10,000 feet. By staying efficient, the K2 eliminates the need to oversize your boiler at higher altitudes.

    Multiple Installation Options
    The K2 model comes with a built-in wall mount allowing for flexibilty in almost any installation situation. The K2's relativley small size and weight allow it to fit in nearly any space.

    Product Includes
    • (1) Burnham K2-080 K2 Hot Water Boiler
    • (1) Wall Mounting Kit
    • (1) Universal Exhaust Vent Termination Kit
    • (1) Miscellanous Parts Kit
Specifications
General Information
Product Line
K2
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Condensing
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
UPC
672616733117
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
80000 BTU
Minimum Input Capacity
16000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
74000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
64000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
94 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Turndown Ratio
5:1
Electrical Data
Voltage
115 Volts
Frequency
60 Hz
Dimensions
Flue Connection Size
2 Inches
Supply Connection
1 Inch
Return Connection
1 Inch
Product Height
35 Inches
Product Width
17 Inches
Product Depth
16.1875 Inches
Shipping Weight
149 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
7163094
Product Specs
+
Specifications
General Information
Product Line
K2
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Condensing
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Wall
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
UPC
672616733117
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
80000 BTU
Minimum Input Capacity
16000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
74000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
64000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
94 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Turndown Ratio
5:1
Electrical Data
Voltage
115 Volts
Frequency
60 Hz
Dimensions
Flue Connection Size
2 Inches
Supply Connection
1 Inch
Return Connection
1 Inch
Product Height
35 Inches
Product Width
17 Inches
Product Depth
16.1875 Inches
Shipping Weight
149 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Certifications
Country of Origin
United States
Energy Star Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
7163094
Reviews
(1)
+
Burnham K2-080 Reviews & Ratings
Product Q&A
(2)
+
Can I use the K2 for a radiant heat system in a driveway for snow melting?
Vance 
from Maryland 
October 19, 2015
Read Response +
Answer
The Burnham K2 Boiler can be used for a snow melting application with heat exchanger and appropriate anti-freeze. Running the fluid directly from the driveway to the boiler can be harmful and cause excessive thermal stress to the boiler.
Hide Response -
Can this boiler be converted to LP?
Cindy 
from West Virginia 
October 05, 2015
Read Response +
Answer
Yes the K2 boiler can be field-converted for LP gas, and includes all the necessary labeling for the conversion. No additional parts are required, but your technician will need a combustion analyzer to make sure the burner is set-up properly for LP operation. Full instructions are available in "Appendix A: Instructions for Conversion of this Boiler for use with LP Gas" of the installation manual.
Hide Response -
Recommended Accessories
+
How-To Articles
+
Manuals
+
 
 
×
Burnham K2WT-080 - 74K BTU - 94.0% AFUE - Hot Water Gas Boiler - Direct Vent
+
Reset View

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort Tumbler
View eComfort LinkedIn Company Profile