Welcome:  Sign In | Contact Us
Call Us: (877) 326-3833

Mitsubishi - 12k BTU Cooling + Heating - M-Series One-Way Ceiling Cassette Air Conditioning System - 19.8 SEER

Mitsubishi - 12k BTU Cooling + Heating - M-Series One-Way Ceiling Cassette Air Conditioning System - 19.8 SEER
Our Price
Compare Prices
Shipping Info
Model: ML-KP12NA.TH
$2,104.50

Only 5 In-Stock
Ships Friday, Nov 22nd
Shipping Crate Icon
Free Shipping
Free Lift Gate Service - 
System BTU/h
Add-Ons
In-Stock Free Shipping$2,104.50Buy Now
$2,104.50Visit Site
Only 5 In-Stock
Ships Friday, Nov 22nd
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • 1
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    For over 50 years, Mitsubishi has remained at the forefront of the mini split industry thanks to their dedication to providing efficient, user-friendly comfort solutions. The ML-KP12NA.TH is a packaged single zone heat pump mini split system designed to bring discreet heating and cooling to any room in your home. The outdoor condenser uses some of the most advanced technology available to modulate temperature without energy-wasting overshoots and short-cycling associated with simpler systems. With an included wireless remote controller, this system is the perfect combination of convenience and comfort for any application.
  • Precision Temperature Control Technology
  • The SUZ-KA outdoor condenser uses inverter technology when cooling or heating your home. Rather than simply turning on and off, the outdoor condenser adjusts output based on temperature demand, resulting in efficient and precise heating and cooling.
  • Hot-Start
  • Mitsubishi's hot start technology prevents cold drafts by delaying fan operation until the heat exchanger has warmed up.
  • Dehumidification
  • When the indoor unit runs in dry mode, the coil's temperature stays just below the dew point of the return air, removing unwanted moisture. This improves comfort and reduces the chance of mold growth and other property damage in the conditioned space.
  • Condensate Removal System
  • The MLZ-KP contains an internal drain mechanism capable of lifting condensate 19-11/16". This simplifies installation and prevents condensate overflow, which can damage or destroy your property.
  • Serviceability
  • The MLZ-KP is designed to fit between standard 16" joists and be serviced from below, making installation and maintenance easier than ever.
  • Product Includes
    • (1) Mitsubishi - 12k BTU - M-Series SUZ Outdoor Condenser - Single Zone Only (SUZ-KA12NA2.MX)
    • (1) Mitsubishi - 12k BTU - M-Series One-Way Ceiling Cassette without Grille - For Multi or Single-Zone (MLZ-KP12NA)
    • (1) Mitsubishi MLP-444W Ceiling Cassette Grille For Mitsubishi MLZ-KP Mini Split Units (MLP-444W)
    Product Note
    This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Wire - This durable, insulated wire provides power to your indoor unit from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system. All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
General Information
Type
Ceiling Cassette
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Learn More A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Heating Capacity
12000 BTU
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
19.8
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.5
HSPF Learn More HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
12.1
Cooling Power Input
960 Watts
Heating Power Input
1300 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
115 Pounds
Shipping Weight
119 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202392019
SUZ-KA12NA2.MX Specifications+
General Information
Type
Outdoor Condenser
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
1
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
12000
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
51 dB
Minimum Sound Level
49 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
9 Amps
Recommended Breaker Size
16 Amps
Dimensions
Maximum Line Length
65 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 5/8 Inches
Product Width
31 1/2 Inches
Product Depth
11 1/4 Inches
Product Weight
81 Pounds
Shipping Weight
88 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
MLZ-KP12NA Specifications+
General Information
Type
Ceiling Cassette
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Grille
Not Included
Required Grille Model
MLP-444W
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Minimum Air Flow
212 CFM
Maximum Air Flow
350 CFM
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
40 dB
Minimum Sound Level
26 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
7 1/2 Inches
Product Width
45 11/16 Inches
Product Depth
15 1/8 Inches
Product Weight
34 Pounds
Grille Depth
15/16 Inch
Grille Width
16 11/16 Inches
Grille Length
47 1/4 Inches
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
MLP-444W Specifications+
General Information
Type
Grille
Dimensions
Product Weight
5 Pounds
Grille Depth
15/16 Inch
Grille Width
16 11/16 Inches
Grille Length
47 1/4 Inches
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Features
Features
    For over 50 years, Mitsubishi has remained at the forefront of the mini split industry thanks to their dedication to providing efficient, user-friendly comfort solutions. The ML-KP12NA.TH is a packaged single zone heat pump mini split system designed to bring discreet heating and cooling to any room in your home. The outdoor condenser uses some of the most advanced technology available to modulate temperature without energy-wasting overshoots and short-cycling associated with simpler systems. With an included wireless remote controller, this system is the perfect combination of convenience and comfort for any application.
  • Precision Temperature Control Technology
  • The SUZ-KA outdoor condenser uses inverter technology when cooling or heating your home. Rather than simply turning on and off, the outdoor condenser adjusts output based on temperature demand, resulting in efficient and precise heating and cooling.
  • Hot-Start
  • Mitsubishi's hot start technology prevents cold drafts by delaying fan operation until the heat exchanger has warmed up.
  • Dehumidification
  • When the indoor unit runs in dry mode, the coil's temperature stays just below the dew point of the return air, removing unwanted moisture. This improves comfort and reduces the chance of mold growth and other property damage in the conditioned space.
  • Condensate Removal System
  • The MLZ-KP contains an internal drain mechanism capable of lifting condensate 19-11/16". This simplifies installation and prevents condensate overflow, which can damage or destroy your property.
  • Serviceability
  • The MLZ-KP is designed to fit between standard 16" joists and be serviced from below, making installation and maintenance easier than ever.
  • Product Includes
    • (1) Mitsubishi - 12k BTU - M-Series SUZ Outdoor Condenser - Single Zone Only (SUZ-KA12NA2.MX)
    • (1) Mitsubishi - 12k BTU - M-Series One-Way Ceiling Cassette without Grille - For Multi or Single-Zone (MLZ-KP12NA)
    • (1) Mitsubishi MLP-444W Ceiling Cassette Grille For Mitsubishi MLZ-KP Mini Split Units (MLP-444W)
    Product Note
    This product requires the following accessories for installation:
    • Line Set - This double insulated tubing transfers refrigerant efficiently between your outdoor condenser and indoor unit.
    • Drain Tubing - Drain tubing facilitates the reliable and effective removal of condensate from your system. It connects your indoor unit to drain locations of your choosing.
    • Disconnect Box & Electrical Whip Kit - The Disconnect Box & Whip Kit provides a safe and simple way to connect your outdoor condenser to your fuse box.
    • Connecting Wire - This durable, insulated wire provides power to your indoor unit from your outdoor condenser.
    • Base Pan Heater - The base pan heater prevents ice from building up on the outdoor unit. Excessive ice build will lead to performance issues and could damage your unit.
    • Outdoor Condenser Plastic Pad or Wall Bracket - We recommend outdoor condensers should not be placed directly on the ground. An outdoor condenser pad or wall bracket will provide a stable way to mount your condenser free from obstructions and debris.
    Adding these accessories to your order will provide a complete, ready-to-install mini split system. All Mini Split Systems require one Primary Mini Split Installation Kit. You may also require one or more Secondary Installation Kits if you have a Multi-Zone system. You will need a Secondary Installation Kit for each additional indoor unit.
Specifications
General Information
Type
Ceiling Cassette
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Learn More A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Heating Capacity
12000 BTU
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
19.8
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.5
HSPF Learn More HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
12.1
Cooling Power Input
960 Watts
Heating Power Input
1300 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
115 Pounds
Shipping Weight
119 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202392019
SUZ-KA12NA2.MX Specifications+
General Information
Type
Outdoor Condenser
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
1
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
12000
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
51 dB
Minimum Sound Level
49 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
9 Amps
Recommended Breaker Size
16 Amps
Dimensions
Maximum Line Length
65 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 5/8 Inches
Product Width
31 1/2 Inches
Product Depth
11 1/4 Inches
Product Weight
81 Pounds
Shipping Weight
88 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
MLZ-KP12NA Specifications+
General Information
Type
Ceiling Cassette
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Grille
Not Included
Required Grille Model
MLP-444W
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Minimum Air Flow
212 CFM
Maximum Air Flow
350 CFM
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
40 dB
Minimum Sound Level
26 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
7 1/2 Inches
Product Width
45 11/16 Inches
Product Depth
15 1/8 Inches
Product Weight
34 Pounds
Grille Depth
15/16 Inch
Grille Width
16 11/16 Inches
Grille Length
47 1/4 Inches
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
MLP-444W Specifications+
General Information
Type
Grille
Dimensions
Product Weight
5 Pounds
Grille Depth
15/16 Inch
Grille Width
16 11/16 Inches
Grille Length
47 1/4 Inches
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Product Specs
+
Specifications
General Information
Type
Ceiling Cassette
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Number of Zones Learn More A zone is a room or area within a building that has its own temperature control.
1
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Line Set Size
1/4" x 3/8"
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Heating Capacity
12000 BTU
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
19.8
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.5
HSPF Learn More HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
12.1
Cooling Power Input
960 Watts
Heating Power Input
1300 Watts
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Dimensions
Product Weight
115 Pounds
Shipping Weight
119 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202392019
SUZ-KA12NA2.MX Specifications+
General Information
Type
Outdoor Condenser
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Maximum Number of Zones
1
Multi-Zone Compatible
No
Refrigerant Type
R-410A
Installation Location
Outdoor
Performance
Cooling BTU
12000
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
51 dB
Minimum Sound Level
49 dB
Low Ambient Heating
Yes
Minimum Outdoor Temperature for Heating Learn More This is the lowest rated outdoor temperature for heating operation. Because heat pumps rely on heat available in outdoor air, the amount of heat they are able to supply decreases with outdoor temperatures. Learn More
-4 F
Minimum Outdoor Temperature for Cooling
14 F
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
9 Amps
Recommended Breaker Size
16 Amps
Dimensions
Maximum Line Length
65 Feet
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
21 5/8 Inches
Product Width
31 1/2 Inches
Product Depth
11 1/4 Inches
Product Weight
81 Pounds
Shipping Weight
88 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
7 Years
MLZ-KP12NA Specifications+
General Information
Type
Ceiling Cassette
Product Line
M-Series
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Multi-Zone Compatible
Yes
Refrigerant Type
R-410A
Indoor Unit Size(s) Learn More Mini split systems can have one or more indoor units connected to a single outdoor unit. Indoor Unit Size(s) specifies what indoor unit sizes are used in a system. We have combined 6k and 7k indoor units to enhance searchability.
12
Installation Location
Indoor
Grille
Not Included
Required Grille Model
MLP-444W
Performance
Cooling BTU
12000
Cooling Capacity
12000 BTU
Minimum Air Flow
212 CFM
Maximum Air Flow
350 CFM
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
40 dB
Minimum Sound Level
26 dB
Electrical Data
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
3/8 Inch
Liquid Connection Size
1/4 Inch
Product Height
7 1/2 Inches
Product Width
45 11/16 Inches
Product Depth
15 1/8 Inches
Product Weight
34 Pounds
Grille Depth
15/16 Inch
Grille Width
16 11/16 Inches
Grille Length
47 1/4 Inches
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
MLP-444W Specifications+
General Information
Type
Grille
Dimensions
Product Weight
5 Pounds
Grille Depth
15/16 Inch
Grille Width
16 11/16 Inches
Grille Length
47 1/4 Inches
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
(1)
+
Search Product Q&A's Answered by Chris, the eComfort Product Expert
icon-social-fb1
+
I'm looking at the Mitsubishi mini split system that uses the recessed cassette. Would the cassette install in a cathedral ceiling with a slant? It would mean that the cassette would be placed at an angle.
A. D. 
from Maryland 
March 10, 2019
Answer
 My apologies, but no, they have to be installed flat due to the drainage of the unit.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Mitsubishi - 12k BTU Cooling + Heating - M-Series One-Way Ceiling Cassette Air Conditioning System - 19.8 SEER
Mitsubishi ML-KP12NA.TH
+
Reset View
Mitsubishi ML-KP12NA.TH
Mitsubishi ML-KP12NA.TH
Mitsubishi ML-KP12NA.TH
Mitsubishi ML-KP12NA.TH
×
Customer Review Images