Local Pickup FAQ's

Hover to zoom
1 Of 5
Dunkirk Q90-200 Quantum High Efficiency Condensing Boiler, Taco Pump - 200,000 BTU
Model:
381001080
+
Share This Product
Recommended Accessories
Expert Recommended Accessories
Selected by Ken, our Expert
Required Accessories
9
These accessories are required to properly setup/install this product.
Optional Accessories
10
Features
- 90% AFUE
- Direct Vent Exhaust
- Cast Aluminum Heat Exchanger
- Safe, Cost Effective PVC Vent Piping
- Simplified Controls
- Environmentally Friendly
- Easy To Install
- Residential Applications: 15 years heat exchanger
- Commercial Applications: 8 years heat exchanger
- Parts: 1 year
Dunkirk Q90-200 Quantum High Efficiency Condensing Boiler, Taco Pump - 200,000 BTU
The Dunkirk Quantum 90 series uses modern technological advances in heating technology to provide an efficient, high performance condensing boiler. The quantum uses a cast aluminum heat exchanger, providing unmatched heat transfer speed as well as high efficiency. The boiler uses sealed combustion technology, preserving in home air quality as well as ensuring a fresh supply of oxygen for the burner. The boiler is capable of achieving up to 90% AFUE in normal residential operation, and can go even higher in low temperature applications.
Dunkirk Q90-200 Quantum High Efficiency Condensing Boiler Features:Specifications
381001080

Performance
Maximum Input Capacity
Maximum Input Capacity
The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
200000 BTU
DOE Heating Capacity
DOE Heating Capacity
Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
180000 BTU
Net I=B=R Capacity
Net I=B=R Capacity
I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
157000 BTU
Efficiency
90 %
Warranty Information
Parts Warranty
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
15 Years
General Information
Medium
Medium
Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Fuel Type
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas (Convertible)
Combustion Type
Combustion Type
Condensing appliances use leftover thermal energy from combustion gases to heat water in a secondary heat exchanger, resulting in higher efficiency and lower exhaust temperature.
Conventional
Vent Type
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production
DHW Production
DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
Yes
Modulating/Staging
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Staging
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Dimensions
Primary Vent Pipe Diameter
3 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
40 1/4 Inches
Product Width
20 1/8 Inches
Product Depth
32 1/8 Inches
Product Weight
284 Pounds
Reviews
Dunkirk 381001080 Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Please share your insights with fellow shoppers.
How-To Articles
How to Pick the Perfect City Multi Outdoor Unit
When dealing with very large buildings with many different zones, choosing a hea...
Smart, Safe, Clean Home Tips
Americans spend around 90 percent of their time indoors, whether it's working, ...
Heat Pump Hybrid Water Heater Buyers Guide
If your gas or electric water heater is nearing the end of its life, replacing ...
Ask A Question!
*Required Fields
+
Thank You For Submitting Your Question
Your submission has been sent successfully. Please give our experts up to two business days to respond.
Media Gallery
Dunkirk Q90-200 Quantum High Efficiency Condensing Boiler, Taco Pump - 200,000 BTU
Customer Review Images