Model: GWA-070-N-T-S2
(Based on expert analysis, manufacturer ratings and customer reviews)
4.7 out of 54.7 out of 54.7 out of 54.7 out of 54.7 out of 5
Number of Reviews (11)
Write A Review
$1,430.95
Only 3 In-Stock
Ships Monday, Oct 22nd
Free Shipping
Free Lift Gate Service - 
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Add-Ons
 
Only 3 In-Stock
Ships Monday, Oct 22nd
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Texas, Utah, California or any destination outside of the United States
Share
  • Product Description
  • 11
    Reviews
  • 6
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    "Uncover warm possibilities" with Williamson-Thermoflo's GWA Gas Water Atmospheric boiler. The highly efficient GWA-070-N-T-S2 pumps out 70,000 BTUs with an AFUE (annual fuel utilization efficiency) rating of 83.0 percent. The GWA is also equipped with flue baffles, stainless steel burners, and an automatic vent damper to maintain that efficiency. This factory-packaged boiler has many features; like a spark (intermittent) pilot system, cast-iron sections with built-in air separator, and an insulated heavy-gauge steel jacket. The GWA is also easily serviced with all controls in reach and a one-piece access door. Since it is factory tested and comes with a limited lifetime warranty, you can be absolutely sure that your investment is reliable and built to last.
  • Factory Tested
  • GWA boilers are factory tested, ensuring reliability and properly functioning equipment.
  • Easy Service
  • Service is simple with a one-piece access door and easily accessible controls.
  • Inferred Heat Program
  • GWA is designed with an inferred heat program which provides automatic adjustment of the boiler water temperature to match heating demands.
  • Limited Lifetime Warranty
  • A limited lifetime warranty on the heat exchanger means that you can rest assured that your investment is covered, should there be a problem.
  • Product Includes
  • Taco 007 Circulator Pump
Specifications
General Information
Product Line
GWA
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
70000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
58000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
50000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
4 Inches
Gas Connection Size
0.5 Inches
Supply Connection
1.25 Inches
Return Connection
1.25 Inches
Product Height
52.375 Inches
Product Width
19 Inches
Product Depth
23.25 Inches
Product Weight
200 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Lifetime Years
Features
Features
    "Uncover warm possibilities" with Williamson-Thermoflo's GWA Gas Water Atmospheric boiler. The highly efficient GWA-070-N-T-S2 pumps out 70,000 BTUs with an AFUE (annual fuel utilization efficiency) rating of 83.0 percent. The GWA is also equipped with flue baffles, stainless steel burners, and an automatic vent damper to maintain that efficiency. This factory-packaged boiler has many features; like a spark (intermittent) pilot system, cast-iron sections with built-in air separator, and an insulated heavy-gauge steel jacket. The GWA is also easily serviced with all controls in reach and a one-piece access door. Since it is factory tested and comes with a limited lifetime warranty, you can be absolutely sure that your investment is reliable and built to last.
  • Factory Tested
  • GWA boilers are factory tested, ensuring reliability and properly functioning equipment.
  • Easy Service
  • Service is simple with a one-piece access door and easily accessible controls.
  • Inferred Heat Program
  • GWA is designed with an inferred heat program which provides automatic adjustment of the boiler water temperature to match heating demands.
  • Limited Lifetime Warranty
  • A limited lifetime warranty on the heat exchanger means that you can rest assured that your investment is covered, should there be a problem.
  • Product Includes
  • Taco 007 Circulator Pump
Specifications
General Information
Product Line
GWA
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
70000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
58000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
50000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
4 Inches
Gas Connection Size
0.5 Inches
Supply Connection
1.25 Inches
Return Connection
1.25 Inches
Product Height
52.375 Inches
Product Width
19 Inches
Product Depth
23.25 Inches
Product Weight
200 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Lifetime Years
Product Specs
+
Specifications
General Information
Product Line
GWA
Medium Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Performance
Maximum Input Capacity The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
70000 BTU
DOE Heating Capacity Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
58000 BTU
Net I=B=R Capacity I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
50000 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83 %
Ultra Low NOx Emissions NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
4 Inches
Gas Connection Size
0.5 Inches
Supply Connection
1.25 Inches
Return Connection
1.25 Inches
Product Height
52.375 Inches
Product Width
19 Inches
Product Depth
23.25 Inches
Product Weight
200 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
Lifetime Years
Reviews
(11)
+
Williamson-Thermoflo GWA-070-N-T-S2 Reviews & Ratings
100% of Reviewers Recommend This Product
Product Q&A
(6)
+
Search Product Q&A's Answered by Bob, the Heating Product Expert
icon-social-fb1
+
Does this unit include a pump? Do you get everything shown in the photo? What is the temperature range of the water it delivers?
Dee And Cindy 
from Oregon 
September 19, 2016
Answer
The GWA-105 boiler comes with a Taco 007 Circulator Pump, and also includes everything in the photo. The controller allows you to select water temperatures ranging from 140F-220F, and will also automatically adjust supply water temperatures to match the heating load.
+
Does this system work if the power is out? My current boiler does but is very inefficient.
Dennis 
from Massachusetts 
July 02, 2016
Answer
This boiler from Williamson-Thermoflo will not work if power is lost.
+
I have a 7" inside measured square clay lined brick chimney in good condition. Do I need a new chimney liner installed?
Louis 
from New Jersey 
March 30, 2016
Answer
I took the following excerpt from the boiler manual: "A lined chimney is preferred and must be used when required by local, state, provincial and national codes, laws, regulations and ordinances. Vitreous tile linings with joints that prevent retention of moisture and linings made of noncorrosive materials are best. Advice for flue connections and chimney linings can be obtained from local gas utility. Type B double-wall metal vent pipe or single-wall vent pipe may be used as a liner."
+
What is the operating temperature range for this boiler?
Mark 
from Michigan 
December 23, 2015
Answer
GWA-series boilers can be adjusted to have a supply water set point as high as 220F, but temperatures above 180 F should be avoided except in exceptional circumstances. The return water should be maintained at no less than 140 F, to prevent condensation of the flue gasses that will lead to premature boiler failure.
+
Can I vent this unit out through an exterior wall with a short vent, instead of through the chimney?
Vince 
from Pennsylvania 
December 18, 2015
Answer
The GWA Series boilers require a chimney to operate properly and the installation you describe could result in the exhaust gases, including carbon monoxide, entering your home. If you would like a boiler that can safely vent through a side wall, I suggest considering on of our power vented models which have a built in blower to push exhaust gases out of the building.
+
What size is the gas pipe feed?
John 
from New Jersey 
October 15, 2015
Answer
The gas connection on GWA boilers is 1/2", though your pipe diameter from the meter to the boiler will depend on local utility requirements. See page 13 of the installation manual for further sizing details.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Williamson-Thermoflo GWA-070 - 58K BTU - 83.0% AFUE - Hot Water Gas Boiler - Chimney Vent
Williamson-Thermoflo GWA-070-N-T-S2
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile