MENU
/
Welcome:  Sign In | Contact Us
Call Us: (877)-412-5296

Tekmar 265 - Boiler Control - Outdoor Temp. Reset - Three Modulating Boiler - DHW/Setpoint

Tekmar 265 - Boiler Control - Outdoor Temp. Reset - Three Modulating Boiler - DHW/Setpoint
Model: 265
$1,082.00
Factory-Direct
Ships in 4-7 Business Days
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping & 
Tax-Free (Except IL)
 
Free ShippingNo Sales Tax* (Except IL)$1,082.00Buy Now
No Sales Tax* (Except IL)$35.99Visit Site
Factory-Direct
Ships in 4-7 Business Days
Enter your ZIP Code below to see an estimated arrival time of delivery to your home or business.
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Free Shipping
Free Shipping
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features

    For nearly three decades, tekmar has been providing zoning and control solutions for a variety of heating and cooling applications. Products made by tekmar can improve the efficiency and comfort delivered by almost any system. The tekmar 265 Boiler Control controls a single water temperature. It is equipped to operate a system pump, DHW pump, boiler pumps, and as many as three modulating boilers in order to satisfy heating demands in a hydronic system. This unit also provides setpoint control, and DHW control is available if setpoint operation is not in use and two or fewer boilers are connected. The 265 Boiler Control possesses several energy saving features, including outdoor temperature reset, to make your system more economical.

    Product Features:

    Intelligent Control
    By monitoring system and outdoor temperatures, the tekmar 265 is able to make intelligent decisions about system operation. This includes adjusting supply temperatures based on outdoor conditions and providing boiler protection by monitoring and maintaining a minimum return water temperature. With the wide variety of operating modes and equipment it supports, the tekmar 374 is sure to make your system operate more efficiently, without sacrificing comfort.

    Setback Period
    The tekmar 265 allows you to designate a setback period when your home or business is unoccupied, reducing the water temperature to limit energy waste.

    Warm Weather Shutdown
    A warm weather shut down temperature may be programmed to prevent your system from running when it in unnecessary or untenable.

    Proportional, Integral, Derivative (PID) Staging Mode
    In PID mode, an advanced algorithm weighs many variables, including sensor temperatures, when making operation decisions. PID reduces short-cycling, improves efficiency, and prevents temperature drops in your system.

    Boiler Rotation
    When you are using the tekmar 265 Boiler Control with two boilers, it will take each boiler's cumulative run time into account when deciding which boiler will fire first. This prevents one of your boilers from being overused.

    Product Includes
    • (1) tekmar 265 Boiler Control
    • (2) tekmar 071 Universal Sensors
    • (1) tekmar 070 Outdoor Sensor
    • (4) 500 Ohm Resistors
Specifications
General Information
Stages
Multi-Stage
Voltage Type
Line-Voltage
Interface
Buttons
Electrical Data
Maximum Load
5 Amps
Dimensions
Product Height
6.625 Inches
Product Width
7.5625 Inches
Product Depth
2.8125 Inches
Product Weight
3.3 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Certifications
UL Listed
Yes
CSA Listed
Yes
Features
Features

    For nearly three decades, tekmar has been providing zoning and control solutions for a variety of heating and cooling applications. Products made by tekmar can improve the efficiency and comfort delivered by almost any system. The tekmar 265 Boiler Control controls a single water temperature. It is equipped to operate a system pump, DHW pump, boiler pumps, and as many as three modulating boilers in order to satisfy heating demands in a hydronic system. This unit also provides setpoint control, and DHW control is available if setpoint operation is not in use and two or fewer boilers are connected. The 265 Boiler Control possesses several energy saving features, including outdoor temperature reset, to make your system more economical.

    Product Features:

    Intelligent Control
    By monitoring system and outdoor temperatures, the tekmar 265 is able to make intelligent decisions about system operation. This includes adjusting supply temperatures based on outdoor conditions and providing boiler protection by monitoring and maintaining a minimum return water temperature. With the wide variety of operating modes and equipment it supports, the tekmar 374 is sure to make your system operate more efficiently, without sacrificing comfort.

    Setback Period
    The tekmar 265 allows you to designate a setback period when your home or business is unoccupied, reducing the water temperature to limit energy waste.

    Warm Weather Shutdown
    A warm weather shut down temperature may be programmed to prevent your system from running when it in unnecessary or untenable.

    Proportional, Integral, Derivative (PID) Staging Mode
    In PID mode, an advanced algorithm weighs many variables, including sensor temperatures, when making operation decisions. PID reduces short-cycling, improves efficiency, and prevents temperature drops in your system.

    Boiler Rotation
    When you are using the tekmar 265 Boiler Control with two boilers, it will take each boiler's cumulative run time into account when deciding which boiler will fire first. This prevents one of your boilers from being overused.

    Product Includes
    • (1) tekmar 265 Boiler Control
    • (2) tekmar 071 Universal Sensors
    • (1) tekmar 070 Outdoor Sensor
    • (4) 500 Ohm Resistors
Specifications
General Information
Stages
Multi-Stage
Voltage Type
Line-Voltage
Interface
Buttons
Electrical Data
Maximum Load
5 Amps
Dimensions
Product Height
6.625 Inches
Product Width
7.5625 Inches
Product Depth
2.8125 Inches
Product Weight
3.3 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Certifications
UL Listed
Yes
CSA Listed
Yes
Product Specs
+
Specifications
General Information
Stages
Multi-Stage
Voltage Type
Line-Voltage
Interface
Buttons
Electrical Data
Maximum Load
5 Amps
Dimensions
Product Height
6.625 Inches
Product Width
7.5625 Inches
Product Depth
2.8125 Inches
Product Weight
3.3 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Certifications
UL Listed
Yes
CSA Listed
Yes
Reviews
+
This product has no reviews.
Be the first to voice your opinion on this Tekmar product.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
How-To Articles
+
Manuals
+
 
 
×
Tekmar 265 - Boiler Control - Outdoor Temp. Reset - Three Modulating Boiler - DHW/Setpoint
+
Reset View

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort Tumbler
View eComfort LinkedIn Company Profile