Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Rinnai EnergySaver EX22C Gas Fired Direct Vent Wall Furnace, LP, Beige - 20,700 BTU

Rinnai EnergySaver EX22C Gas Fired Direct Vent Wall Furnace, LP, Beige - 20,700 BTU
Model: RHFE-559FTA-A-P
Product Discontinued
Sorry, this product is no longer available.
Continue Shopping With These Categories
Discontinued
Sorry, this product is no longer available
Free Freight
Free Freight
*We currently CANNOT ship this product to Canada or any destination outside of the United States
  • Product Description
  • 1
    Reviews
  • 2
    Product Q&A
  • How-To Articles
  • Manuals
Product Description
+
Features
Features

    Rinnai EnergySaver EX22C Gas Fired Direct Vent Wall Furnace, LP, Beige - 20,700 BTU

    The Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace Direct Vent Wall Furnace is a fantastic heating unit. A programmable thermostat designed in a user friendly manner ensures that you can quickly and easily set your home to the temperature of your choosing. The Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace is safety-conscious as well, sporting a "cool to touch" cabinet and child safety lock. The Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace is also energy efficient, with a standby power of less than 1 Watt and 7-state modulating gas valve with variable speed blower to use only what it needs to warm your environment. A self-diagnostic with error code indicator system, backed by a warranties covering the heat exchanger, parts and labor make the Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace a long lasting heating unit.

    Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace Features:
    • Rated to 16,560 BTU
    • 7-State Modulating Gas Valve and Variable Speed Blower
    • User Friendly Control System with Programmable Thermostat
    • Self-Diagnostic with Error Code Indicator
    • Whisper Quiet Fan
    • Cool to Touch Cabinet
    Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace Warranty Information:
    • Heat Exchanger: 12 Years
    • Parts: 2 Years
Specifications
General Information
Type
Gas Wall Furnace
Product Line
Energysaver
Product Sub-line
EX22C
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Blower Type Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Variable-Speed
Gas Conversion Kit
Available
Color
Beige
Performance
Nominal Heating Capacity
20700 BTU
High Fire Input
20700 BTU
High Fire Output
16974 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82 %
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
42 dB
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
0.5 Inches
Supply Connection
0.5 Inches
Product Height
22.88 Inches
Product Width
29.88 Inches
Product Depth
10.13 Inches
Product Weight
57 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
12 Years
Certifications
CSA Listed
Yes
Features
Features

    Rinnai EnergySaver EX22C Gas Fired Direct Vent Wall Furnace, LP, Beige - 20,700 BTU

    The Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace Direct Vent Wall Furnace is a fantastic heating unit. A programmable thermostat designed in a user friendly manner ensures that you can quickly and easily set your home to the temperature of your choosing. The Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace is safety-conscious as well, sporting a "cool to touch" cabinet and child safety lock. The Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace is also energy efficient, with a standby power of less than 1 Watt and 7-state modulating gas valve with variable speed blower to use only what it needs to warm your environment. A self-diagnostic with error code indicator system, backed by a warranties covering the heat exchanger, parts and labor make the Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace a long lasting heating unit.

    Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace Features:
    • Rated to 16,560 BTU
    • 7-State Modulating Gas Valve and Variable Speed Blower
    • User Friendly Control System with Programmable Thermostat
    • Self-Diagnostic with Error Code Indicator
    • Whisper Quiet Fan
    • Cool to Touch Cabinet
    Rinnai RHFE-559FTA-A-P Gas Fired Direct Vent Wall Furnace Warranty Information:
    • Heat Exchanger: 12 Years
    • Parts: 2 Years
Specifications
General Information
Type
Gas Wall Furnace
Product Line
Energysaver
Product Sub-line
EX22C
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Blower Type Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Variable-Speed
Gas Conversion Kit
Available
Color
Beige
Performance
Nominal Heating Capacity
20700 BTU
High Fire Input
20700 BTU
High Fire Output
16974 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82 %
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
42 dB
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
0.5 Inches
Supply Connection
0.5 Inches
Product Height
22.88 Inches
Product Width
29.88 Inches
Product Depth
10.13 Inches
Product Weight
57 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
12 Years
Certifications
CSA Listed
Yes
Product Specs
+
Specifications
General Information
Type
Gas Wall Furnace
Product Line
Energysaver
Product Sub-line
EX22C
Fuel Type To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Liquid Propane
Vent Type Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Blower Type Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
ECM Variable-Speed
Gas Conversion Kit
Available
Color
Beige
Performance
Nominal Heating Capacity
20700 BTU
High Fire Input
20700 BTU
High Fire Output
16974 BTU
AFUE AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
82 %
Maximum Sound Level Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
42 dB
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Gas Connection Size
0.5 Inches
Supply Connection
0.5 Inches
Product Height
22.88 Inches
Product Width
29.88 Inches
Product Depth
10.13 Inches
Product Weight
57 Pounds
Warranty Information
Parts Warranty A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
2 Years
Heat Exchanger Warranty
12 Years
Certifications
CSA Listed
Yes
Reviews
(1)
+
Rinnai RHFE-559FTA-A-P Reviews & Ratings
Product Q&A
(2)
+
If power is lost, will it turn back on automatically when power is restored?
Ed 
from California 
December 23, 2015
Read Response +
Answer
Yes, as long as they were on prior to the power failure, the EnergySaver series wall furnaces will restart automatically once power is restored.
Hide Response -
Any special wiring needed for this heater?
Pat 
from Pennsylvania 
October 24, 2015
Read Response +
Answer
Rinnai suggests that a dedicated electrical circuit with a 120V AC, 60 Hz, 10 amp power source be used. You can find full installation instructions in the owners manual linked on the manuals tab, or here.

Thanks for your question!
Hide Response -
How-To Articles
+
Manuals
+
 
 
×
Rinnai EnergySaver EX22C Gas Fired Direct Vent Wall Furnace, LP, Beige - 20,700 BTU
+
Reset View

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile