Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Rheem - 3.5 Ton Cooling - 100k BTU/Hr Heating - Air Conditioner + Furnace Kit - 14.5 SEER - 80% AFUE - For Downflow Installation

Rheem - 3.5 Ton Cooling - 100k BTU/Hr Heating - Air Conditioner + Furnace Kit - 14.5 SEER - 80% AFUE - For Downflow Installation
Our Price
Compare Prices
Shipping Info
Model: WA1442W801T100D
$3,269.00

Only 1 In-Stock
Ships Thursday, Dec 12th
Shipping Crate Icon
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Cooling Capacity (Tons) Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
Furnace Capacity (BTU/h)
Configuration
Furnace Width (Inches)
Add-Ons
Only 1 In-Stock
Ships Thursday, Dec 12th
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Arizona, California, New Mexico, Nevada or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Rheem provides reliable home comfort solutions with its WeatherKing line of HVAC systems. The WA1442W801T100D kit includes an air conditioner, furnace, and cased evaporator coil, providing everything you need to update your home's central air system. The WA14 air conditioner features a louvered steel cabinet to protect the unit from the elements and uses a wrap-around outdoor coil for improved airflow and heat transfer. The W801T furnace features a high-efficiency blower motor, providing powerful home heating without you having to worry about the energy bill. Each component of the kit is built with durability and reliability in mind, allowing for hassle-free home comfort for years to come.
  • Wrap-Around Coil
  • The WeatherKing WA14 implements a unique wrap-around coil which improves air flow and heat transfer while reducing energy consumption.
  • Solid Construction
  • Made with a sturdy louvered steel cabinet, the WA14 is built to withstand inclement weather, yard hazards, and corrosion.
  • Quiet Operation
  • Several characteristics of the WA14 reduce sound and vibration: a motor mount/grille combination, the discharge pattern of the top grilles that minimizes air restriction, and a one-piece base pan that elevates the coil off the pad to reduce vibration.
  • Direct Spark Ignition
  • The WeatherKing W801T features a direct spark ignition system, the same used on gas ovens and stoves. This means the furnace will only fire when it is needed, unlike a less efficient constant pilot light.
  • Aluminized Steel Heat Exchanger
  • The aluminized steel heat exchanger in the W801T provides incredibly efficient heat transfer as well as maximum corrosion resistance and thermal fatigue reliability.
  • LED Display
  • An industry first, WeatherKing furnaces feature a 7-segment LED display, making service calls quick and easy.
  • Product Includes
    • (1) Rheem WA14 - 3.5 Ton - Air Conditioner - 14 Nominal SEER - Single-Stage - R-410A Refrigerant (WA1442CJ1NA)
    • (1) Rheem W801T - 100k BTU - Gas Furnace - 80% AFUE (W801TA100521ZSB)
    • (1) Rheem TCF - 4 Ton - High Efficiency - Multi-Position N Coil - Cased - 24.5" Width (TCF4824HTAMCA)
    Product Note
    The recommended line set size for this system will vary based on the length of line set you require for installation. | The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help.
Specifications
General Information
Product Line
WeatherKing
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
ECM Multi-Speed
Coil Width
24.5 Inches
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North and Southeast
Installation Available
No
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling Capacity
41500 BTU
Nominal Cooling Capacity
42000 BTU
Heating BTU
100000
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.5
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.0
Maximum Air Flow
1450 CFM
Dimensions
Shipping Weight
412 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202865165
WA1442CJ1NA Specifications+
General Information
Type
Condenser
Product Line
WeatherKing
Product Sub-line
WA14
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Learn More Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North and Southeast
Performance
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling BTU
42000
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
11.5
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
23 Amps
Recommended Breaker Size
35 Amps
Dimensions
Suction Connection Size
7/8 Inch
Liquid Connection Size
3/8 Inch
Product Height
32 1/4 Inches
Product Width
27 5/8 Inches
Product Depth
27 5/8 Inches
Product Weight
176 Pounds
Shipping Weight
184 Pounds
Certifications
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
5 Years
W801TA100521ZSB Specifications+
General Information
Type
Gas Furnace
Product Line
WeatherKing
Product Sub-line
W801T
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
PSC Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Available
Installation Available
No
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
100000
High Fire Output
82000 BTU
High Fire Input
100000 BTU
Maximum Air Flow
2072 CFM
Ultra Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
12 Amps
Recommended Breaker Size
15 Amps
Dimensions
Cabinet Width
21 Inches
Product Height
34 Inches
Product Width
21 Inches
Product Depth
29 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
10 Years
TCF4824HTAMCA Specifications+
General Information
Type
Evaporator Coil
Product Line
WeatherKing
Product Sub-line
TCF
Refrigerant Type
R-410A
Casing
Cased
Style
N Coil
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Multi-Position
Installation Available
No
Performance
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Cooling BTU
48000
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
24 1/2 Inches
Product Height
32 Inches
Product Width
24 1/2 Inches
Product Depth
19 7/8 Inches
Product Weight
108 Pounds
Shipping Weight
108 Pounds
Certifications
UL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Features
Features
    Rheem provides reliable home comfort solutions with its WeatherKing line of HVAC systems. The WA1442W801T100D kit includes an air conditioner, furnace, and cased evaporator coil, providing everything you need to update your home's central air system. The WA14 air conditioner features a louvered steel cabinet to protect the unit from the elements and uses a wrap-around outdoor coil for improved airflow and heat transfer. The W801T furnace features a high-efficiency blower motor, providing powerful home heating without you having to worry about the energy bill. Each component of the kit is built with durability and reliability in mind, allowing for hassle-free home comfort for years to come.
  • Wrap-Around Coil
  • The WeatherKing WA14 implements a unique wrap-around coil which improves air flow and heat transfer while reducing energy consumption.
  • Solid Construction
  • Made with a sturdy louvered steel cabinet, the WA14 is built to withstand inclement weather, yard hazards, and corrosion.
  • Quiet Operation
  • Several characteristics of the WA14 reduce sound and vibration: a motor mount/grille combination, the discharge pattern of the top grilles that minimizes air restriction, and a one-piece base pan that elevates the coil off the pad to reduce vibration.
  • Direct Spark Ignition
  • The WeatherKing W801T features a direct spark ignition system, the same used on gas ovens and stoves. This means the furnace will only fire when it is needed, unlike a less efficient constant pilot light.
  • Aluminized Steel Heat Exchanger
  • The aluminized steel heat exchanger in the W801T provides incredibly efficient heat transfer as well as maximum corrosion resistance and thermal fatigue reliability.
  • LED Display
  • An industry first, WeatherKing furnaces feature a 7-segment LED display, making service calls quick and easy.
  • Product Includes
    • (1) Rheem WA14 - 3.5 Ton - Air Conditioner - 14 Nominal SEER - Single-Stage - R-410A Refrigerant (WA1442CJ1NA)
    • (1) Rheem W801T - 100k BTU - Gas Furnace - 80% AFUE (W801TA100521ZSB)
    • (1) Rheem TCF - 4 Ton - High Efficiency - Multi-Position N Coil - Cased - 24.5" Width (TCF4824HTAMCA)
    Product Note
    The recommended line set size for this system will vary based on the length of line set you require for installation. | The US Department of Energy regulates minimum efficiency standards for central air conditioners and heat pumps based on geographic regions. We are required to abide by these regulations when selling products, and take this responsibility seriously. The standards depend on the rated efficiency of the entire system, not the nominal efficiencies of individual components. If you are unsure if your system will be compliant, please call or email us for help.
Specifications
General Information
Product Line
WeatherKing
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
ECM Multi-Speed
Coil Width
24.5 Inches
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North and Southeast
Installation Available
No
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling Capacity
41500 BTU
Nominal Cooling Capacity
42000 BTU
Heating BTU
100000
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.5
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.0
Maximum Air Flow
1450 CFM
Dimensions
Shipping Weight
412 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202865165
WA1442CJ1NA Specifications+
General Information
Type
Condenser
Product Line
WeatherKing
Product Sub-line
WA14
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Learn More Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North and Southeast
Performance
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling BTU
42000
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
11.5
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
23 Amps
Recommended Breaker Size
35 Amps
Dimensions
Suction Connection Size
7/8 Inch
Liquid Connection Size
3/8 Inch
Product Height
32 1/4 Inches
Product Width
27 5/8 Inches
Product Depth
27 5/8 Inches
Product Weight
176 Pounds
Shipping Weight
184 Pounds
Certifications
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
5 Years
W801TA100521ZSB Specifications+
General Information
Type
Gas Furnace
Product Line
WeatherKing
Product Sub-line
W801T
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
PSC Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Available
Installation Available
No
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
100000
High Fire Output
82000 BTU
High Fire Input
100000 BTU
Maximum Air Flow
2072 CFM
Ultra Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
12 Amps
Recommended Breaker Size
15 Amps
Dimensions
Cabinet Width
21 Inches
Product Height
34 Inches
Product Width
21 Inches
Product Depth
29 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
10 Years
TCF4824HTAMCA Specifications+
General Information
Type
Evaporator Coil
Product Line
WeatherKing
Product Sub-line
TCF
Refrigerant Type
R-410A
Casing
Cased
Style
N Coil
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Multi-Position
Installation Available
No
Performance
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Cooling BTU
48000
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
24 1/2 Inches
Product Height
32 Inches
Product Width
24 1/2 Inches
Product Depth
19 7/8 Inches
Product Weight
108 Pounds
Shipping Weight
108 Pounds
Certifications
UL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Product Specs
+
Specifications
General Information
Product Line
WeatherKing
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
ECM Multi-Speed
Coil Width
24.5 Inches
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North and Southeast
Installation Available
No
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling Capacity
41500 BTU
Nominal Cooling Capacity
42000 BTU
Heating BTU
100000
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.5
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
12.0
Maximum Air Flow
1450 CFM
Dimensions
Shipping Weight
412 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
202865165
WA1442CJ1NA Specifications+
General Information
Type
Condenser
Product Line
WeatherKing
Product Sub-line
WA14
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Cooling
Refrigerant Type
R-410A
Installation Location
Outdoor
Compressor Stages Learn More Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Single
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
North and Southeast
Performance
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
3.5 Tons
Cooling BTU
42000
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
11.5
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
14.0
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
23 Amps
Recommended Breaker Size
35 Amps
Dimensions
Suction Connection Size
7/8 Inch
Liquid Connection Size
3/8 Inch
Product Height
32 1/4 Inches
Product Width
27 5/8 Inches
Product Depth
27 5/8 Inches
Product Weight
176 Pounds
Shipping Weight
184 Pounds
Certifications
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Compressor Warranty
5 Years
W801TA100521ZSB Specifications+
General Information
Type
Gas Furnace
Product Line
WeatherKing
Product Sub-line
W801T
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
PSC Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Available
Installation Available
No
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
100000
High Fire Output
82000 BTU
High Fire Input
100000 BTU
Maximum Air Flow
2072 CFM
Ultra Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
12 Amps
Recommended Breaker Size
15 Amps
Dimensions
Cabinet Width
21 Inches
Product Height
34 Inches
Product Width
21 Inches
Product Depth
29 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
10 Years
TCF4824HTAMCA Specifications+
General Information
Type
Evaporator Coil
Product Line
WeatherKing
Product Sub-line
TCF
Refrigerant Type
R-410A
Casing
Cased
Style
N Coil
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Multi-Position
Installation Available
No
Performance
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
4.0 Tons
Cooling BTU
48000
Dimensions
Suction Connection Size
3/4 Inch
Liquid Connection Size
3/8 Inch
Cabinet Width
24 1/2 Inches
Product Height
32 Inches
Product Width
24 1/2 Inches
Product Depth
19 7/8 Inches
Product Weight
108 Pounds
Shipping Weight
108 Pounds
Certifications
UL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Rheem - 3.5 Ton Cooling - 100k BTU/Hr Heating - Air Conditioner + Furnace Kit - 14.5 SEER - 80% AFUE - For Downflow Installation
Rheem WA1442W801T100D
+
Reset View
Rheem WA1442W801T100D
Rheem WA1442W801T100D
Rheem WA1442W801T100D
Rheem WA1442W801T100D
×
Customer Review Images