Model: 92-2-N
$6,006.95
Factory-Direct
Ships in 3-4 Weeks
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Add-Ons
 
Factory-Direct
Ships in 3-4 Weeks
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to California or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    For over a century Peerless has dedicated itself to making efficient, durable boilers. Their Cast 92 hot water boilers represent these qualities in all regards. Solid cast iron construction of the boiler sections and heat exchanger is one of the highlights of the Cast 92 line. The 92-2-N also includes an advanced control board, with a simplified display, that can connect to building management systems. These qualities combine to make a sturdy boiler that is very user friendly. Reliability and ease of use are not the only defining characteristics of the Cast 92 line
Specifications
General Information
Product Line
Cast 92
Medium ? Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Condensing
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production ? DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
199000 BTU
Minimum Input Capacity
40000 BTU
DOE Heating Capacity ? Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
184000 BTU
Net I=B=R Capacity ? I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
150000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
90 %
Ultra Low NOx Emissions ? NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Turndown Ratio
5:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
1/2 Inch
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
51 1/8 Inches
Product Width
17 3/16 Inches
Product Depth
28 3/8 Inches
Product Weight
540 Pounds
Shipping Height
61 1/4 Inches
Shipping Width
25 Inches
Shipping Depth
34 Inches
Shipping Weight
510 Pounds
Certifications
Country of Origin
United States
Energy Star Listed
Yes
CSA Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
2105061
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Features
Features
    For over a century Peerless has dedicated itself to making efficient, durable boilers. Their Cast 92 hot water boilers represent these qualities in all regards. Solid cast iron construction of the boiler sections and heat exchanger is one of the highlights of the Cast 92 line. The 92-2-N also includes an advanced control board, with a simplified display, that can connect to building management systems. These qualities combine to make a sturdy boiler that is very user friendly. Reliability and ease of use are not the only defining characteristics of the Cast 92 line
Specifications
General Information
Product Line
Cast 92
Medium ? Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Condensing
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production ? DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
199000 BTU
Minimum Input Capacity
40000 BTU
DOE Heating Capacity ? Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
184000 BTU
Net I=B=R Capacity ? I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
150000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
90 %
Ultra Low NOx Emissions ? NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Turndown Ratio
5:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
1/2 Inch
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
51 1/8 Inches
Product Width
17 3/16 Inches
Product Depth
28 3/8 Inches
Product Weight
540 Pounds
Shipping Height
61 1/4 Inches
Shipping Width
25 Inches
Shipping Depth
34 Inches
Shipping Weight
510 Pounds
Certifications
Country of Origin
United States
Energy Star Listed
Yes
CSA Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
2105061
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Product Specs
+
Specifications
General Information
Product Line
Cast 92
Medium ? Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Condensing
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
DHW Production ? DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Modulating
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
10000 Feet
Includes Pump
Yes
Assembly Type
Packaged
Gas Conversion Kit
Included
Performance
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
199000 BTU
Minimum Input Capacity
40000 BTU
DOE Heating Capacity ? Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
184000 BTU
Net I=B=R Capacity ? I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
150000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
90 %
Ultra Low NOx Emissions ? NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Turndown Ratio
5:1
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
3 Inches
Gas Connection Size
1/2 Inch
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
51 1/8 Inches
Product Width
17 3/16 Inches
Product Depth
28 3/8 Inches
Product Weight
540 Pounds
Shipping Height
61 1/4 Inches
Shipping Width
25 Inches
Shipping Depth
34 Inches
Shipping Weight
510 Pounds
Certifications
Country of Origin
United States
Energy Star Listed
Yes
CSA Listed
Yes
ASME Certified
Yes
AHRI Certified
Yes
AHRI Reference Number
2105061
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
10 Years
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Peerless 92-2 - 184K BTU - 90.0% AFUE - Hot Water Gas Boiler - Direct Vent
Peerless 92-2-N
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile