Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Hover to zoom
1 Of 5
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA

Oxbox J951X - 54k BTU - Gas Furnace - 95% AFUE

Model:

J951X054BU4SAA

Write A Review
Product Discontinued
Sorry, this product is no longer available.
Oxbox J951X - 54k BTU - Gas Furnace - 95% AFUE
Oxbox J951X - 54k BTU - Gas Furnace - 95% AFUE
Model: J951X054BU4SAA
Product Discontinued
Features
Specifications
Reviews
How-To Articles
Manuals
Share

Features

    Oxbox furnaces provide reliable heating throughout the winter months with components that are built to last. With an aluminized steel heat exchanger and secondary stainless steel heat exchanger, the furnace is able to conduct heat quickly while remaining durable for years to come. A galvanized steel cabinet protects from corrosion, while a silicon nitride igniter ensures proper operation when you need it. The furnace is certified to achieve the Energy Star cabinet leakage requirement of less than or equal to 2%, allowing for little to no wasted energy.
  • Aluminized Steel Heat Exchanger
  • Oxbox furnaces feature aluminized steel heat exchangers to conduct heat quickly and increase durability.
  • Secondary Heat Exchanger
  • A secondary stainless steel heat exchanger transfers leftover heat from the first, maximizing efficiency while providing even more heat for your home.
  • Silicon Nitride Igniters
  • Oxbox furnaces include silicon nitride igniters to ensure heating operation whenever you need it.
  • Durable Cabinet
  • The furnace features a galvanized steel cabinet to resist corrosion and remain reliable for years to come.
  • Product Note
  • In order to maintain the warranty, product must be installed by a licensed contractor. Proof of installation by a licensed contractor is required.
California residents see
Warning: This product can expose you to chemicals including Lead and lead compounds which is known to the State of California to cause Cancer.
For more information go to: www.p65Warnings.ca.gov

Specifications

J951X054BU4SAA
specs product image PID-110469
Overview
Product Category
Furnace
Additional Model Numbers

J951X054BU4SAA, J951X054BU4SAA

General Information
Type
Gas Furnace
Product Line
J951X
Product Category
Furnace
Fuel Type Learn More
Fuel Type
To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More
Vent Type
Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More
Modulating/Staging
Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor Type
ECM Multi-Speed
Configuration Learn More
Configuration
Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Performance
AFUE Learn More
AFUE
AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
95 %
Heating BTU
54000
High Fire Input
54000 BTU
High Fire Output
51000 BTU
Maximum Air Flow
1600 CFM
Ultra Low NOx Emissions Learn More
Ultra Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Low NOx Emissions Learn More
Low NOx Emissions
NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
9.3 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 or 3 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 Inches
Product Weight
119 Pounds
Shipping Height
35 3/4 Inches
Shipping Width
21 1/4 Inches
Shipping Length
31 Inches
Shipping Weight
131 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Parts Warranty Learn More
Parts Warranty
A warranty is a safeguard from defects in manufacturing and can vary in length and terms. Some manufacturers require registration for extended warranty benefits, be sure to check out features and the warranty document. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years

Reviews

Oxbox J951X054BU4SAA Reviews & Ratings
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.

How-To Articles

How Gas Furnaces Work
How Gas Furnaces Work
Do you wish you had a better grasp on things when the heat goes out and your fa...
Modulating, Single Stage & Two Stage Furnaces
Modulating, Single Stage & Two Stage Furnaces
Think back to a time when you were playing a sport. If you’re like me, yo...
How to Pick the Perfect Furnace
How to Pick the Perfect Furnace
The heart of nearly every forced air heating system is the furnace. Gas furnace...
eComfort How-To Library
eComfort How-To Library
Articles, Tips and Buying Guides from Our Experts

Manuals

 
Media Gallery
Oxbox J951X - 54k BTU - Gas Furnace - 95% AFUE
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Oxbox J951X054BU4SAA
Customer Review Images