Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Goodman - 2.0 Ton Cooling - 40k BTU/Hr Heating - Two-Stage Heat Pump + Furnace Kit - 17.5 SEER - 96% AFUE - For Upflow Installation

Goodman - 2.0 Ton Cooling - 40k BTU/Hr Heating - Two-Stage Heat Pump + Furnace Kit - 17.5 SEER - 96% AFUE - For Upflow Installation
Our Price
Compare Prices
Shipping Info
Model: GSZC1824GMVC96040U
$4,548.00
Add to Cart for Lower Price

Ships in 7-14 Business Days
Shipping Crate Icon
Free Shipping
Free Lift Gate Service - 
Cooling Capacity (Tons) Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
Orientation Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Furnace Capacity (BTU/h)
Furnace Width (Inches)
Add-Ons
 
Ships in 7-14 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    A Goodman high efficiency heat pump and furnace package is the perfect way to upgrade your home's HVAC system. This kit contains a GSZC two-stage heat pump with an advanced coil design to maximize efficiency. The heat pump is paired with a GMVC furnace equipped with an ECM variable speed motor. This pair was specifically chosen to provide efficient comfort year round. A cased coil and valve kit are included, making this kit an affordable, efficient, whole home solution.
  • Quiet Comfort
  • The wire fan discharge grille and condenser fan motor of the GSZC line were designed to reduce noise levels without compromising performance. This model also has a high-capacity discharge muffler and a high-density foam sound blanket.
  • SmartShift
  • Goodman's SmartShift technology, combined with ambient and coil temperature sensors, gives this unit a quiet and effective defrost system. SmartShift also helps to prevent short-cycling, increasing the efficiency of defrost operations.
  • UltraTech Compressor
  • A two-stage Copeland UltraTech scroll compressor provides the GSZC with incredibly reliable refrigerant flow. The second stage increases efficiency by allowing the compressor to operate at a lower capacity when your demand is low.
  • All-Aluminum Coil
  • Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort.
  • Condensate Management
  • The included coil features foil-faced insulation to inhibit the formation of condensate and a rust-resistant thermoplastic drain pan to capture what does form, keeping your system safe and operational.
  • Advanced Heat Exchanger Design
  • The GMVC furnace employs a dual-diameter tubular heat exchanger design. Aluminized steel is used in construction for efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance dependability and longevity.
  • Secondary Heat Exchanger
  • This furnace produces additional heat without using more fuel by directing combustion gases through a secondary heat exchanger before they are vented. To prevent damage, this secondary heat exchanger is made of corrosion-resistant stainless steel.
  • Variable Speed ECM Motor
  • The GMVC line features a variable speed ECM motor. Variable speed motors allow the furnace to operate at higher efficiencies than multi-speed blowers by controlling the speed of the blower based on heating demands.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
  • Product Includes
    • (1) Goodman GSZC18 - 2 Ton - Heat Pump - 18 Nominal SEER - Two-Stage - R-410a Refrigerant (GSZC180241)
    • (1) Goodman GMVC96 - 40k BTU - Two-Stage Gas Furnace - 96% AFUE (GMVC960403BN)
    • (1) Goodman CAPF - 2.5 - 3.0 Ton - Upflow/Downflow A Coil - Cased - 17.5" Width (CAPF3137B6)
    • (1) Goodman TXV Kit - 1.5-2 Ton - R-410A (TX2N4A)
    Product Note
    The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab.
Specifications
General Information
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Variable-Speed
Coil Width
17.5 Inches
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Installation Available
Yes
Performance
Cooling Capacity
23600 BTU
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Heating BTU
40000
Nominal Cooling Capacity
24000 BTU
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
17.5
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
13.5
HSPF Learn More HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9.6
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
810 CFM
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
10570165
GSZC180241 Specifications+
General Information
Type
Condenser
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Refrigerant Type
R-410a
Installation Location
Outdoor
Compressor Stages Learn More Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Two
Installation Available
Yes
Performance
Cooling BTU
24000
Cooling Capacity
24000 BTU
Heating Capacity
23000 BTU
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
18
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
68 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15 Amps
Recommended Breaker Size
25 Amps
Dimensions
Liquid Connection Size
3/8 Inch
Suction Connection Size
7/8 Inch
Product Height
40 Inches
Product Width
35 1/2 Inches
Product Depth
35 1/2 Inches
Product Weight
230 Pounds
Shipping Weight
250 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Limited* 10 Years Years
Compressor Warranty
LIFETIME Years
GMVC960403BN Specifications+
General Information
Type
Gas Furnace
Product Line
GMVC96
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Variable-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
Heating BTU
40000
High Fire Input
40000 BTU
Low Fire Input
28000 BTU
High Fire Output
38400 BTU
Low Fire Output
26880 BTU
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
1200 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
7.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
114 Pounds
Shipping Weight
114 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368841
Warranty Information
Unit Replacement Warranty
10 Years
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
CAPF3137B6 Specifications+
General Information
Type
Evaporator Coil
Product Line
CAPF
Refrigerant Type
R-410A
Casing
Cased
Style
A Coil
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
Performance
Cooling BTU
36000
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.5 - 3.0 Tons
Nominal Minimum Cooling Capacity
30000 BTU
Dimensions
Liquid Connection Size
3/8 Inch
Suction Connection Size
3/4 Inch
Cabinet Width
17 1/2 Inches
Product Height
30 Inches
Product Width
17 1/2 Inches
Product Depth
21 Inches
Product Weight
53 Pounds
Shipping Weight
53 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
TX2N4A Specifications+
General Information
Type
TXV Kit
Product Line
TX
Refrigerant Type
R-410A
Dimensions
Product Weight
1 Pound
Shipping Weight
2 Pounds
Features
Features
    A Goodman high efficiency heat pump and furnace package is the perfect way to upgrade your home's HVAC system. This kit contains a GSZC two-stage heat pump with an advanced coil design to maximize efficiency. The heat pump is paired with a GMVC furnace equipped with an ECM variable speed motor. This pair was specifically chosen to provide efficient comfort year round. A cased coil and valve kit are included, making this kit an affordable, efficient, whole home solution.
  • Quiet Comfort
  • The wire fan discharge grille and condenser fan motor of the GSZC line were designed to reduce noise levels without compromising performance. This model also has a high-capacity discharge muffler and a high-density foam sound blanket.
  • SmartShift
  • Goodman's SmartShift technology, combined with ambient and coil temperature sensors, gives this unit a quiet and effective defrost system. SmartShift also helps to prevent short-cycling, increasing the efficiency of defrost operations.
  • UltraTech Compressor
  • A two-stage Copeland UltraTech scroll compressor provides the GSZC with incredibly reliable refrigerant flow. The second stage increases efficiency by allowing the compressor to operate at a lower capacity when your demand is low.
  • All-Aluminum Coil
  • Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort.
  • Condensate Management
  • The included coil features foil-faced insulation to inhibit the formation of condensate and a rust-resistant thermoplastic drain pan to capture what does form, keeping your system safe and operational.
  • Advanced Heat Exchanger Design
  • The GMVC furnace employs a dual-diameter tubular heat exchanger design. Aluminized steel is used in construction for efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance dependability and longevity.
  • Secondary Heat Exchanger
  • This furnace produces additional heat without using more fuel by directing combustion gases through a secondary heat exchanger before they are vented. To prevent damage, this secondary heat exchanger is made of corrosion-resistant stainless steel.
  • Variable Speed ECM Motor
  • The GMVC line features a variable speed ECM motor. Variable speed motors allow the furnace to operate at higher efficiencies than multi-speed blowers by controlling the speed of the blower based on heating demands.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
  • Product Includes
    • (1) Goodman GSZC18 - 2 Ton - Heat Pump - 18 Nominal SEER - Two-Stage - R-410a Refrigerant (GSZC180241)
    • (1) Goodman GMVC96 - 40k BTU - Two-Stage Gas Furnace - 96% AFUE (GMVC960403BN)
    • (1) Goodman CAPF - 2.5 - 3.0 Ton - Upflow/Downflow A Coil - Cased - 17.5" Width (CAPF3137B6)
    • (1) Goodman TXV Kit - 1.5-2 Ton - R-410A (TX2N4A)
    Product Note
    The recommended line set size for this system will vary based on the length of line set you require for installation. Compatible line sets can be found under the "Recommended Accessories" tab.
Specifications
General Information
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Variable-Speed
Coil Width
17.5 Inches
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Installation Available
Yes
Performance
Cooling Capacity
23600 BTU
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Heating BTU
40000
Nominal Cooling Capacity
24000 BTU
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
17.5
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
13.5
HSPF Learn More HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9.6
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
810 CFM
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
10570165
GSZC180241 Specifications+
General Information
Type
Condenser
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Refrigerant Type
R-410a
Installation Location
Outdoor
Compressor Stages Learn More Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Two
Installation Available
Yes
Performance
Cooling BTU
24000
Cooling Capacity
24000 BTU
Heating Capacity
23000 BTU
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
18
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
68 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15 Amps
Recommended Breaker Size
25 Amps
Dimensions
Liquid Connection Size
3/8 Inch
Suction Connection Size
7/8 Inch
Product Height
40 Inches
Product Width
35 1/2 Inches
Product Depth
35 1/2 Inches
Product Weight
230 Pounds
Shipping Weight
250 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Limited* 10 Years Years
Compressor Warranty
LIFETIME Years
GMVC960403BN Specifications+
General Information
Type
Gas Furnace
Product Line
GMVC96
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Variable-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
Heating BTU
40000
High Fire Input
40000 BTU
Low Fire Input
28000 BTU
High Fire Output
38400 BTU
Low Fire Output
26880 BTU
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
1200 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
7.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
114 Pounds
Shipping Weight
114 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368841
Warranty Information
Unit Replacement Warranty
10 Years
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
CAPF3137B6 Specifications+
General Information
Type
Evaporator Coil
Product Line
CAPF
Refrigerant Type
R-410A
Casing
Cased
Style
A Coil
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
Performance
Cooling BTU
36000
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.5 - 3.0 Tons
Nominal Minimum Cooling Capacity
30000 BTU
Dimensions
Liquid Connection Size
3/8 Inch
Suction Connection Size
3/4 Inch
Cabinet Width
17 1/2 Inches
Product Height
30 Inches
Product Width
17 1/2 Inches
Product Depth
21 Inches
Product Weight
53 Pounds
Shipping Weight
53 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
TX2N4A Specifications+
General Information
Type
TXV Kit
Product Line
TX
Refrigerant Type
R-410A
Dimensions
Product Weight
1 Pound
Shipping Weight
2 Pounds
Product Specs
+
Specifications
General Information
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Variable-Speed
Coil Width
17.5 Inches
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow
DOE Regional Compliance Learn More In 2015, the US Department of Energy broke the country into three regions - North, Southeast, and Southwest - and set legal standards for energy efficiency within each region. Learn More
Nationwide
Installation Available
Yes
Performance
Cooling Capacity
23600 BTU
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
Heating BTU
40000
Nominal Cooling Capacity
24000 BTU
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
17.5
EER Learn More EER (Energy Efficiency Ratio) is a measurement of cooling efficiency under fixed conditions. It is useful for comparing units that will operate consistently under one set of conditions (e.g. server room). The higher the EER, the more efficient the system. Learn More
13.5
HSPF Learn More HSPF (Heating Seasonal Performance Factor) is a measure of heating efficiency for heat pumps. It is useful for comparing energy efficiency of heat pumps. The higher the HSPF, the more efficient the system. Learn More
9.6
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
810 CFM
Certifications
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
10570165
GSZC180241 Specifications+
General Information
Type
Condenser
Operating Mode Learn More Some products are only capable of cooling, while others can either heat or cool a space. Some products heat via "heat pump" technology while others use electric heating elements. Learn More
Heating and Cooling
Refrigerant Type
R-410a
Installation Location
Outdoor
Compressor Stages Learn More Stages are the distinct levels of output that an air conditioner or heat pump can deliver. Having more than one stage allows the equipment to better match the needs of the space and deliver better comfort and more efficiency.
Two
Installation Available
Yes
Performance
Cooling BTU
24000
Cooling Capacity
24000 BTU
Heating Capacity
23000 BTU
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.0 Tons
SEER Learn More SEER (Seasonal Energy Efficiency Ratio) is a measurement of cooling efficiency over a typical cooling season. It is useful for comparing energy efficiency of cooling systems. The higher the SEER, the more energy efficient the system. Learn More
18
Maximum Sound Level Learn More Sound levels are measured in decibels (dB). The lower the decibel rating, the less noise the product makes. As an example, a ticking watch is 20 dB while on the other end of the scale, a lawn mower is around 90 dB. Learn More
68 dB
Electrical Data
Voltage
208/230 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15 Amps
Recommended Breaker Size
25 Amps
Dimensions
Liquid Connection Size
3/8 Inch
Suction Connection Size
7/8 Inch
Product Height
40 Inches
Product Width
35 1/2 Inches
Product Depth
35 1/2 Inches
Product Weight
230 Pounds
Shipping Weight
250 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
Limited* 10 Years Years
Compressor Warranty
LIFETIME Years
GMVC960403BN Specifications+
General Information
Type
Gas Furnace
Product Line
GMVC96
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Direct Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Variable-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
Heating BTU
40000
High Fire Input
40000 BTU
Low Fire Input
28000 BTU
High Fire Output
38400 BTU
Low Fire Output
26880 BTU
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
96 %
Maximum Air Flow
1200 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
7.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
2 Inches
Cabinet Width
17 1/2 Inches
Product Height
34 1/2 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Product Weight
114 Pounds
Shipping Weight
114 Pounds
Certifications
ETL Listed
Yes
Energy Star Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
7368841
Warranty Information
Unit Replacement Warranty
10 Years
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
CAPF3137B6 Specifications+
General Information
Type
Evaporator Coil
Product Line
CAPF
Refrigerant Type
R-410A
Casing
Cased
Style
A Coil
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Downflow
Installation Available
Yes
Performance
Cooling BTU
36000
Capacity Learn More Tonnage, or tons of cooling, is a short hand method for describing the capacity of cooling equipment. One ton is equal to approximately 12 kBTU/hr.
2.5 - 3.0 Tons
Nominal Minimum Cooling Capacity
30000 BTU
Dimensions
Liquid Connection Size
3/8 Inch
Suction Connection Size
3/4 Inch
Cabinet Width
17 1/2 Inches
Product Height
30 Inches
Product Width
17 1/2 Inches
Product Depth
21 Inches
Product Weight
53 Pounds
Shipping Weight
53 Pounds
Certifications
ETL Listed
Yes
AHRI Certified
Yes
Warranty Information
Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
TX2N4A Specifications+
General Information
Type
TXV Kit
Product Line
TX
Refrigerant Type
R-410A
Dimensions
Product Weight
1 Pound
Shipping Weight
2 Pounds
Reviews
+
Be the First to Write a Review
Do you own this product?
Please share your insights with fellow shoppers.
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Goodman - 2.0 Ton Cooling - 40k BTU/Hr Heating - Two-Stage Heat Pump + Furnace Kit - 17.5 SEER - 96% AFUE - For Upflow Installation
Goodman GSZC1824GMVC96040U
+
Reset View
Goodman GSZC1824GMVC96040U
Goodman GSZC1824GMVC96040U
Goodman GSZC1824GMVC96040U
Goodman GSZC1824GMVC96040U
Goodman GSZC1824GMVC96040U
Goodman GSZC1824GMVC96040U
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort on Instagram