Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Goodman GME8 - 100k BTU - Two-Stage Gas Furnace - 80% AFUE

Add Installation & Save with Code: good10
Goodman GME81005CN
Goodman GME81005CN
Goodman GME81005CN
Goodman GME81005CN
Goodman GME8 - 100k BTU - Two-Stage Gas Furnace - 80% AFUE
Our Price
Compare Prices
Shipping Info
Model: GME81005CN
(Based on expert analysis, manufacturer ratings and customer reviews)
4.8 out of 54.8 out of 54.8 out of 54.8 out of 54.8 out of 5
Number of Reviews (4)
Write A Review
Product Discontinued
Sorry, this product is no longer available.
Try This Instead
Model: 
GMEC801005CN
$1,117.00
Factory-Direct
Discontinued
Sorry, this product is no longer available
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to California or any destination outside of the United States
Share
  • Product Description
  • 4
    Reviews
  • 1
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GME8 two-stage, multi-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. It is equipped with a four-speed ECM blower motor, which provides your home with comfortable, efficient circulation through a wide variety of conditions. The GME81005CN was designed for ease of installation, it has multiple options for orientation and gas and electrical connections. Maintenance is just as easy as installation thanks to the unit's self-diagnosing control board. Backed by Goodman's generous warranty, the GME8 provides comfort and peace of mind to homeowners.
  • Advanced Heat Exchanger Design
  • The GME8 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
  • Dual$aver Technology
  • Dual$aver Technology allows GME8 furnaces to begin operating at the lower stage for ideal efficiency. The control board uses historical data about the rate of temperature change in your home to decide whether the higher stage of heating is necessary.
  • Quiet Comfort
  • The blower, gas valve, and draft inducer of the GME81005CN were selected for their incredibly low sound levels. Additionally, this unit's fan speed options make it easy to maintain virtually silent circulation.
  • Secure Cabinet
  • All GME8 furnaces are protected by a durable steel cabinet with an insulated heat exchanger section to prevent heat loss.
  • Easy Integration
  • The GME81005CN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
  • Extended Warranty
  • Goodman offers a 10-year limited unit replacement and parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See the "Manuals" tab for more information.
Specifications
General Information
Type
Gas Furnace
Product Line
GME8
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
UPC
663051572386
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
High Fire Output
80000 BTU
High Fire Input
100000 BTU
Heating BTU
100000
Low Fire Input
75000 BTU
Low Fire Output
60000 BTU
Maximum Air Flow
2000 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
14.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
21 Inches
Product Height
33 3/8 Inches
Product Width
21 Inches
Product Depth
28 3/4 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5012584
Warranty Information
Unit Replacement Warranty
10 Years
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Features
Features
    Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GME8 two-stage, multi-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. It is equipped with a four-speed ECM blower motor, which provides your home with comfortable, efficient circulation through a wide variety of conditions. The GME81005CN was designed for ease of installation, it has multiple options for orientation and gas and electrical connections. Maintenance is just as easy as installation thanks to the unit's self-diagnosing control board. Backed by Goodman's generous warranty, the GME8 provides comfort and peace of mind to homeowners.
  • Advanced Heat Exchanger Design
  • The GME8 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
  • Dual$aver Technology
  • Dual$aver Technology allows GME8 furnaces to begin operating at the lower stage for ideal efficiency. The control board uses historical data about the rate of temperature change in your home to decide whether the higher stage of heating is necessary.
  • Quiet Comfort
  • The blower, gas valve, and draft inducer of the GME81005CN were selected for their incredibly low sound levels. Additionally, this unit's fan speed options make it easy to maintain virtually silent circulation.
  • Secure Cabinet
  • All GME8 furnaces are protected by a durable steel cabinet with an insulated heat exchanger section to prevent heat loss.
  • Easy Integration
  • The GME81005CN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
  • Extended Warranty
  • Goodman offers a 10-year limited unit replacement and parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See the "Manuals" tab for more information.
Specifications
General Information
Type
Gas Furnace
Product Line
GME8
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
UPC
663051572386
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
High Fire Output
80000 BTU
High Fire Input
100000 BTU
Heating BTU
100000
Low Fire Input
75000 BTU
Low Fire Output
60000 BTU
Maximum Air Flow
2000 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
14.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
21 Inches
Product Height
33 3/8 Inches
Product Width
21 Inches
Product Depth
28 3/4 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5012584
Warranty Information
Unit Replacement Warranty
10 Years
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Product Specs
+
Specifications
General Information
Type
Gas Furnace
Product Line
GME8
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Motor
ECM Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Upflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
UPC
663051572386
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
High Fire Output
80000 BTU
High Fire Input
100000 BTU
Heating BTU
100000
Low Fire Input
75000 BTU
Low Fire Output
60000 BTU
Maximum Air Flow
2000 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
14.8 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
21 Inches
Product Height
33 3/8 Inches
Product Width
21 Inches
Product Depth
28 3/4 Inches
Product Weight
120 Pounds
Shipping Weight
120 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5012584
Warranty Information
Unit Replacement Warranty
10 Years
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Reviews
(4)
+
Goodman GME81005CN Reviews & Ratings
Product Q&A
(1)
+
Search Product Q&A's Answered by Bob, the Heating Product Expert
icon-social-fb1
+
Can this unit be used in California?
Francisco 
from California 
December 28, 2015
Answer
Goodman makes special Low NOx models for use in California and other areas that limit nitrous oxide emissions. These models can be easily found and identified because that have an 'X' instead of an 'N' at the end of the model number. All of the high-efficiency models (AFUE >= 90%), are compliant with these emissions regulations.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Goodman GME8 - 100k BTU - Two-Stage Gas Furnace - 80% AFUE
Goodman GME81005CN
+
Reset View
Goodman GME81005CN
Goodman GME81005CN
Goodman GME81005CN
×
Customer Review Images