Goodman GDH8 - 80k BTU - Two-Stage Gas Furnace - 80% AFUE

Goodman GDH8 - 80k BTU - Two-Stage Gas Furnace - 80% AFUE
Our Price
Compare Prices
Shipping Info
Model: GDH80804BN
(Based on expert analysis, manufacturer ratings and customer reviews)
4.6 out of 54.6 out of 54.6 out of 54.6 out of 54.6 out of 5
Number of Reviews (11)
Write A Review
$656.00
Only 3 In-Stock
Ships Tuesday, Dec 18th
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Gas Valve Stages ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control.
Low NOx Output
Add-Ons
 
Only 3 In-Stock
Ships Tuesday, Dec 18th
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to California, Texas or any destination outside of the United States
Share
  • Product Description
  • 11
    Reviews
  • 3
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GDH8 two-stage, multi-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. This furnace also excels at providing comfortable circulation in a variety of conditions thanks to its four-speed blower motor. Designed for ease of installation, the GDH8 furnace has multiple options for gas, electrical, and return air connections. Maintenance is just as easy thanks to the unit's self-diagnosing control board. Backed by Goodman's generous warranty, the GDH8 provides comfort and peace of mind to homeowners.
  • Advanced Heat Exchanger Design
  • The GDH8 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
  • Dual$aver Technology
  • Dual$aver Technology allows GDH8 furnaces to begin operating at the lower stage for ideal efficiency. The control board uses historical data about the rate of temperature change in your home to decide whether the higher stage of heating is necessary.
  • Quiet Comfort
  • The blower, motor, and gas valve of the GDH80804BN were selected for their incredibly low sound levels.
  • Secure Cabinet
  • All GDH8 furnaces are protected by a durable steel cabinet with a long-lasting powder paint finish. The heat exchanger section of the cabinet is lined with foil-insulation to prevent heat loss.
  • Easy Integration
  • The GDH80804BN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
Specifications
General Information
Type
Gas Furnace
Product Line
GDH8
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Type ? Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
PSC Multi-Speed
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Available
UPC
663051572287
Performance
Nominal Heating Capacity
80000 BTU
High Fire Input
80000 BTU
High Fire Output
64000 BTU
Low Fire Input
60000 BTU
Low Fire Output
48000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Maximum Air Flow
1600 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
12.9 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Product Height
33 3/8 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Shipping Weight
106 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5012572
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Features
Features
    Goodman established itself as the largest HVAC manufacturer in the US by producing high-quality, efficient equipment and providing it to homeowners at a great value. The GDH8 two-stage, multi-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. This furnace also excels at providing comfortable circulation in a variety of conditions thanks to its four-speed blower motor. Designed for ease of installation, the GDH8 furnace has multiple options for gas, electrical, and return air connections. Maintenance is just as easy thanks to the unit's self-diagnosing control board. Backed by Goodman's generous warranty, the GDH8 provides comfort and peace of mind to homeowners.
  • Advanced Heat Exchanger Design
  • The GDH8 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
  • Dual$aver Technology
  • Dual$aver Technology allows GDH8 furnaces to begin operating at the lower stage for ideal efficiency. The control board uses historical data about the rate of temperature change in your home to decide whether the higher stage of heating is necessary.
  • Quiet Comfort
  • The blower, motor, and gas valve of the GDH80804BN were selected for their incredibly low sound levels.
  • Secure Cabinet
  • All GDH8 furnaces are protected by a durable steel cabinet with a long-lasting powder paint finish. The heat exchanger section of the cabinet is lined with foil-insulation to prevent heat loss.
  • Easy Integration
  • The GDH80804BN makes it simple to enhance your system with a humidifier and an electronic air cleaner; just wire them directly to the low-voltage terminals on the control board.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
Specifications
General Information
Type
Gas Furnace
Product Line
GDH8
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Type ? Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
PSC Multi-Speed
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Available
UPC
663051572287
Performance
Nominal Heating Capacity
80000 BTU
High Fire Input
80000 BTU
High Fire Output
64000 BTU
Low Fire Input
60000 BTU
Low Fire Output
48000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Maximum Air Flow
1600 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
12.9 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Product Height
33 3/8 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Shipping Weight
106 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5012572
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Product Specs
+
Specifications
General Information
Type
Gas Furnace
Product Line
GDH8
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Two Stage
Blower Type ? Blower type describes the motor that powers the fan in the unit. PSC multi-speed is the standard motor that operates with pre-set fan speed levels. ECM multi-speed are more efficient but still operate with pre-set fan speeds. Finally, ECM variable-speed motors are also energy efficient and automatically adjust to changing system conditions.
PSC Multi-Speed
Orientation ? Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow
Gas Conversion Kit
Available
UPC
663051572287
Performance
Nominal Heating Capacity
80000 BTU
High Fire Input
80000 BTU
High Fire Output
64000 BTU
Low Fire Input
60000 BTU
Low Fire Output
48000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Maximum Air Flow
1600 CFM
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
12.9 Amps
Recommended Breaker Size
15 Amps
Dimensions
Flue Connection Size
4 Inches
Product Height
33 3/8 Inches
Product Width
17 1/2 Inches
Product Depth
28 3/4 Inches
Shipping Weight
106 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
5012572
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
5 Years
Heat Exchanger Warranty
20 Years
Reviews
(11)
+
Goodman GDH80804BN Reviews & Ratings
100% of Reviewers Recommend This Product
Product Q&A
(3)
+
Search Product Q&A's Answered by Chris, the eComfort Product Expert
icon-social-fb1
+
Where is cold air return located on this product?
Ken K. 
from Michigan 
September 13, 2016
Answer
The GDH8 downflow furnace has the return opening on the top. Please refer to the install manual for more details
+
Can this unit be used in California?
Francisco 
from California 
December 28, 2015
Answer
Goodman makes special Low NOx models for use in California and other areas that limit nitrous oxide emissions. These models can be easily found and identified because that have an 'X' instead of an 'N' at the end of the model number. All of the high-efficiency models (AFUE >= 90%), are compliant with these emissions regulations.
+
Can this furnace be converted to propane?
Scott 
from Pennsylvania 
December 04, 2015
Answer
Yes, the Goodman GDH8 series furnaces can be converted to propane with the LPM-06 LP Conversion Kit.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Chris
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Goodman GDH8 - 80k BTU - Two-Stage Gas Furnace - 80% AFUE
Goodman GDH80804BN
+
Reset View
Goodman GDH80804BN
Goodman GDH80804BN
Goodman GDH80804BN
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile