Welcome:  Sign In | Contact Us
Call Us: (877) 436-6469

Goodman GCES80 - 100k BTU - Gas Furnace - 80% AFUE

Goodman GCES80 - 100k BTU - Gas Furnace - 80% AFUE
Our Price
Compare Prices
Shipping Info
Model: GCES801005CX
(Based on expert analysis, manufacturer ratings and customer reviews)
5.0 out of 55.0 out of 55.0 out of 55.0 out of 55.0 out of 5
Number of Reviews (1)
Write A Review
$880.00

Ships in 4-7 Business Days
Shipping Crate Icon
Free Shipping
Free Lift Gate Service - 
Orientation Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Low NOx Ouput
Add-Ons
Ships in 4-7 Business Days
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Canada or any destination outside of the United States
Share
  • Product Description
  • 1
    Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    Goodman's GCES80 furnaces feature high-quality construction and efficient operation at a great value. The GCES80 single-stage, multi-speed furnaces utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. Instead of a standard multi-speed blower motor, the GCES80 utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GCES80 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GCES80.
  • Advanced Heat Exchanger Design
  • The GCES80 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
  • Multi-Speed ECM Motor
  • The GCES80's energy efficient blower motor uses the lowest speed it can to deliver precise temperature control for your home while keeping utility bills to a minimum.
  • Quiet Comfort
  • The blower and gas valve of the GCES80 were selected for their incredibly low sound levels. Additionally, this unit offers an airflow system and fan speed options that allow it to operate quietly while providing consistent comfort.
  • Secure Cabinet
  • All GCES80 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is insulated to prevent heat loss and the return side of the cabinet is solid and airtight.
  • Self-Diagnostic Control Board
  • The GCES80 continuously monitors the system to ensure reliable operation, stores the last diagnostic codes in memory, and a flashing LED indicates condition for quick troubleshooting.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
Specifications
General Information
Type
Gas Furnace
Product Line
GCES80
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
ECM Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
100000
High Fire Input
100000 BTU
High Fire Output
80000 BTU
Maximum Air Flow
2000 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15.3 Amps
Recommended Breaker Size
20 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
21 Inches
Product Height
33 1/2 Inches
Product Width
21 Inches
Product Depth
28 Inches
Shipping Weight
115 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
203401042
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Heat Exchanger Warranty
Lifetime Years
Features
Features
    Goodman's GCES80 furnaces feature high-quality construction and efficient operation at a great value. The GCES80 single-stage, multi-speed furnaces utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. Instead of a standard multi-speed blower motor, the GCES80 utilizes an ECM motor, which uses less power and provides smarter circulation. The value doesn't end at efficiency, the GCES80 features many different connection options to reduce installation time and a self-diagnosing control board to expedite maintenance. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the GCES80.
  • Advanced Heat Exchanger Design
  • The GCES80 furnace employs a reliable dual-diameter tubular heat exchanger design. Aluminized steel is used for incredibly efficient heat transfer, and a wrinkle-bend is applied to the tubes to enhance the heat exchanger's dependability and longevity.
  • Multi-Speed ECM Motor
  • The GCES80's energy efficient blower motor uses the lowest speed it can to deliver precise temperature control for your home while keeping utility bills to a minimum.
  • Quiet Comfort
  • The blower and gas valve of the GCES80 were selected for their incredibly low sound levels. Additionally, this unit offers an airflow system and fan speed options that allow it to operate quietly while providing consistent comfort.
  • Secure Cabinet
  • All GCES80 furnaces are protected by a durable steel cabinet rated for less than 2% air leakage. The heat exchanger section is insulated to prevent heat loss and the return side of the cabinet is solid and airtight.
  • Self-Diagnostic Control Board
  • The GCES80 continuously monitors the system to ensure reliable operation, stores the last diagnostic codes in memory, and a flashing LED indicates condition for quick troubleshooting.
  • Extended Warranty
  • Goodman offers a 10-year limited parts warranty when you register your product online within 60 days of installation. An unregistered product has the standard 5-year warranty. See warranty sheet under the "Manuals" tab for more information.
Specifications
General Information
Type
Gas Furnace
Product Line
GCES80
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
ECM Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
100000
High Fire Input
100000 BTU
High Fire Output
80000 BTU
Maximum Air Flow
2000 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15.3 Amps
Recommended Breaker Size
20 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
21 Inches
Product Height
33 1/2 Inches
Product Width
21 Inches
Product Depth
28 Inches
Shipping Weight
115 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
203401042
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Heat Exchanger Warranty
Lifetime Years
Product Specs
+
Specifications
General Information
Type
Gas Furnace
Product Line
GCES80
Fuel Type Learn More To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Vent Type Learn More Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
Modulating/Staging Learn More Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Blower Motor
ECM Multi-Speed
Configuration Learn More Orientation describes the direction that air will flow through a piece of equipment. (e.g. air will flow horizontally through a "Horizontal" unit heater.) Most equipment will only function properly if installed in the proper orientation.
Downflow/Horizontal
Gas Conversion Kit
Available
Installation Available
Yes
Performance
AFUE Learn More AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
80 %
Heating BTU
100000
High Fire Input
100000 BTU
High Fire Output
80000 BTU
Maximum Air Flow
2000 CFM
Low NOx Emissions Learn More NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Low NOx appliances emit less than 40 ng/J (nanogram per Joule) of NOx. Learn More
Yes
Electrical Data
Voltage
115 Volts
Phase
1
Frequency
60 Hz
Minimum Circuit Ampacity
15.3 Amps
Recommended Breaker Size
20 Amps
Dimensions
Flue Connection Size
4 Inches
Cabinet Width
21 Inches
Product Height
33 1/2 Inches
Product Width
21 Inches
Product Depth
28 Inches
Shipping Weight
115 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
ISO Certified
Yes
AHRI Reference Number
203401042
Warranty Information
Parts Warranty Learn More A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
10 Years
Heat Exchanger Warranty
Lifetime Years
Reviews
(1)
+
Goodman GCES801005CX Reviews & Ratings
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Goodman GCES80 - 100k BTU - Gas Furnace - 80% AFUE
Goodman GCES801005CX
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort on Instagram
View eComfort LinkedIn Company Profile