Welcome:  Sign In | Contact Us
Call Us: (877)-412-5296

Crown Boiler AWR140 - 117K BTU - 83.6% AFUE - Hot Water Gas Boiler - Chimney Vent

Crown Boiler AWR140 - 117K BTU - 83.6% AFUE - Hot Water Gas Boiler - Chimney Vent
Our Price
Compare Prices
Shipping Info
Model: AWR140ENSZ2PSU
(Based on expert analysis, manufacturer ratings and customer reviews)
5.0 out of 55.0 out of 55.0 out of 55.0 out of 55.0 out of 5
Number of Reviews (5)
Write A Review
$1,999.99
In-Stock
Ships Wednesday, Dec 19th
Free Shipping
Free Lift Gate Service - 
Holiday Shipping Schedule
Holiday Schedule - 
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Add-Ons
 
In-Stock
Ships Wednesday, Dec 19th
Free Freight
Free Freight
Lift Gate Services
Lift Gate Service
*We currently CANNOT ship this product to Texas, Utah, California or any destination outside of the United States
Share
  • Product Description
  • 5
    Reviews
  • Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Features
Features
    The Aruba line of boilers has been a long standing signature line for Crown with its rock solid reliability and adaptability to nearly any installation conditions. At its core is a sturdy cast iron heat exchanger guaranteed to withstand years of operation without a hitch. A proprietary touchscreen control is included with the boiler, providing a single access point for low water cutoff, temperature, and ignition configuration. Gas can be supplied to the boiler from either side, allowing the Aruba to fit into nearly any space in your utility room. Proven in thousands of installations, Aruba a solid choice for any home heating application.
  • Cast Iron Heat Exchanger
  • The heat exchanger at the core of the Aruba is made of durable cast iron, a material proven many times over for its reliability in heating applications.
  • Included Proprietary Control
  • This boiler comes with a control designed in-house specifically for operation with the Aruba 4 line. Because the control is designed to fit the boiler, it improves the reliability of operations and integrates seamlessly into unique applications.
  • Built-In Rear Draft Diverter
  • Crown's Aruba 4 boilers come stock with a rear draft diverter, making the boiler perfectly suited to low clearance installations.
  • Easily Convertible to Left Side Piping
  • The internal layout of the boiler makes field conversion to left side supply and return piping a simple task, further increasing the versatility of the Aruba 4's placement in your utility room.
Specifications
General Information
Product Line
Aruba 4
Medium ? Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production ? DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
No
Assembly Type
Packaged
Performance
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity ? Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
117000 BTU
Net I=B=R Capacity ? I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
102000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83.6 %
Ultra Low NOx Emissions ? NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
39 1/2 Inches
Product Width
18 1/2 Inches
Product Depth
31 1/2 Inches
Product Weight
384 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
4861646
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
20 Years
Features
Features
    The Aruba line of boilers has been a long standing signature line for Crown with its rock solid reliability and adaptability to nearly any installation conditions. At its core is a sturdy cast iron heat exchanger guaranteed to withstand years of operation without a hitch. A proprietary touchscreen control is included with the boiler, providing a single access point for low water cutoff, temperature, and ignition configuration. Gas can be supplied to the boiler from either side, allowing the Aruba to fit into nearly any space in your utility room. Proven in thousands of installations, Aruba a solid choice for any home heating application.
  • Cast Iron Heat Exchanger
  • The heat exchanger at the core of the Aruba is made of durable cast iron, a material proven many times over for its reliability in heating applications.
  • Included Proprietary Control
  • This boiler comes with a control designed in-house specifically for operation with the Aruba 4 line. Because the control is designed to fit the boiler, it improves the reliability of operations and integrates seamlessly into unique applications.
  • Built-In Rear Draft Diverter
  • Crown's Aruba 4 boilers come stock with a rear draft diverter, making the boiler perfectly suited to low clearance installations.
  • Easily Convertible to Left Side Piping
  • The internal layout of the boiler makes field conversion to left side supply and return piping a simple task, further increasing the versatility of the Aruba 4's placement in your utility room.
Specifications
General Information
Product Line
Aruba 4
Medium ? Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production ? DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
No
Assembly Type
Packaged
Performance
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity ? Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
117000 BTU
Net I=B=R Capacity ? I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
102000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83.6 %
Ultra Low NOx Emissions ? NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
39 1/2 Inches
Product Width
18 1/2 Inches
Product Depth
31 1/2 Inches
Product Weight
384 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
4861646
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
20 Years
Product Specs
+
Specifications
General Information
Product Line
Aruba 4
Medium ? Medium refers to the substance that carries heat through the heating system. Systems are either designed to use either Hot Water or Steam as a medium, and components are usually specific to one or the other.
Hot Water
Heat Exchanger Material
Cast Iron
Fuel Type ? To create heat, some form of fuel is required. Fuel Type specifies what the product uses as an input to create heat.
Natural Gas
Combustion Type
Conventional
Vent Type ? Products that use combustion (burning) of fuel to create heat also create potentially dangerous gasses that need to be exhausted (AKA "Vented"). Depending on the product, venting can be done via a chimney, through a side wall, or use a second vent to provide fresh air to the appliance.
Chimney Vent
DHW Production ? DHW (Domestic Hot Water) is potable water for uses other than space heat. Some boilers are able to provide DHW "out of the box", while others can do so with the purchase of optional accessories.
No
Modulating/Staging ? Stages are unique speeds or levels that equipment can operate at. More stages allow for better fine-tuned control of output, which improves comfort and efficiency. Modulating equipment can operate across a range of levels, giving the highest level of fine-tuned control. Learn More
Single Stage
Mount Type
Floor
Minimum Altitude
0 Feet
Maximum Altitude
2000 Feet
Includes Pump
No
Assembly Type
Packaged
Performance
Maximum Input Capacity ? The Maximum Input Capacity describes how quickly the appliance will use fuel when delivering it's maximum capacity. The units may change depending on the fuel being used.
140000 BTU
DOE Heating Capacity ? Also referred to as Gross Output, this is the output of a boiler after accounting for combustion efficiency. We recommend sizing hot water boilers based on the DOE Heating Capacity.
117000 BTU
Net I=B=R Capacity ? I=B=R, also referred to as Net Output or AHRI Capacity, is the rated heat output of a boiler after accounting for combustion efficiency, piping loss, and an extra pickup factor. We recommend sizing steam boilers based on the I=B=R rating.
102000 BTU
AFUE ? AFUE (Annual Fuel Utilization Efficiency) measures the efficiency of combustion equipment over the entire heating season, and is calculated by dividing the amount of energy that is actually heating your home by the total energy contained in the fuel used by the boiler/furnace. Learn More
83.6 %
Ultra Low NOx Emissions ? NOx is a byproduct of the combustion process, and it's output is regulated in some jurisdictions. Many regulators mirror SCAQMD rules, which regulate air quality for some parts of Southern California. Ultra Low NOx appliances emit less than 10-14 ng/J (nanogram per Joule) of NOx. Learn More
No
Electrical Data
Voltage
120 Volts
Phase
1
Frequency
60 Hz
Dimensions
Flue Connection Size
6 Inches
Supply Connection
1 1/4 Inches
Return Connection
1 1/4 Inches
Product Height
39 1/2 Inches
Product Width
18 1/2 Inches
Product Depth
31 1/2 Inches
Product Weight
384 Pounds
Certifications
Country of Origin
United States
ETL Listed
Yes
AHRI Certified
Yes
AHRI Reference Number
4861646
Warranty Information
Parts Warranty ? A warranty is a safeguard from defects in manufacturing and can vary in length and terms. To see the manufacturer's warranty statement, click on the Manuals tab. Learn More
1 Year
Heat Exchanger Warranty
20 Years
Reviews
(5)
+
Crown Boiler Co. AWR140ENSZ2PSU Reviews & Ratings
Product Q&A
+
Be the first to ask a question.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Bob
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Crown Boiler AWR140 - 117K BTU - 83.6% AFUE - Hot Water Gas Boiler - Chimney Vent
Crown Boiler Co. AWR140ENSZ2PSU
+
Reset View
×
Customer Review Images

Visit eComfort on Facebook
View the eComfort Twitter Profile Page
Follow eComfort on Pinterest
View eComfort YouTube Channel
View eComfort LinkedIn Company Profile